28
RUNNING BELT ADJUSTMENT
Running belt adjustment
1.
If the belt is slightly off-center, first run the
treadmill without anyone on it at a medium
speed for at least 5 to 10 minutes to see whe-
ther the treadmill could automatically center
the running belt. If not, move to step 2 to start
centering the belt.
2. If the belt tracks off center to the left or right,
pay attention to the following process to cen-
ter the belt:
If the running belt is off center to the LEFT:
Use the Allen Wrench
a. to turn the left rear roller adjustment bolt ¼ turn in clockwise direction, which moves the run-
ning belt to the right.
b. or turn the right rear roller adjustment bolt ¼ turn in counterclockwise direction, which moves
the running belt to the right.
If the running belt is off center to the RIGHT:
Use the Allen Wrench
a. to turn the right rear roller adjustment bolt ¼ turn in clockwise direction, which moves the run-
ning belt to the left.
b. or turn the left rear roller adjustment bolt ¼ turn in counterclockwise direction, which moves
the running belt to the left.
Caution: Do not turn the adjustment bolts more than ¼ turn at a time. Overtightening the
belt can damage the treadmill. Be very careful to keep your fingers and any objects away
from the belt and rollers.
3. Repeat the above procedure until the walking belt is centered. It may be necessary to test wal-
king belt tension once you have completed the above procedure if the belt feels like it’s slipping
while walking.
Refer to the below “
Walking Belt Slipping
” instructions:
a. First remove and unplug the power cord. Using the Allen Wrench, turn both left and right rear
roller adjustment bolts
clockwise
, usually a ¼ turn.
NOTE: NEVER TURN the bolts more
then 1/4 turn at a time and always keep the running belt centered.
b. Test the tightness of the belt.
NOTE: Overtightening the belt can damage the treadmill
.
c. Plug in the power cord, insert the key and walk on the treadmill at low speed to determine if
the belt is still slipping. If the belt is still slipping, repeat the above procedure until the walking
belt has been tightened properly.