SL1188P Ultrasonic transit-time flowmeter
Revision
:
2.0.0
Page
1
of
81
Ultrasonic Flowmeter Instruction Manual
Model: SL1188P
Date
September.2012
Update
Record
Page 1: ...SL1188P Ultrasonic transit time flowmeter Revision 2 0 0 Page 1 of 81 Ultrasonic Flowmeter Instruction Manual Model SL1188P Revision 2 0 0 Date September 2012 Revision Update Record Date ...
Page 2: ...nt appears with information that is important to protect people and equipment from damage Pay very close attention to all warnings that apply to your application Failure to comply with these instructions may damage the meter ATTENTION Failure to comply with these instructions may result in faulty operation NOTE Note indicates that ignoring the relevant requirements or precautions may result in flo...
Page 3: ...in accordance with the packing list Make sure that there is no shipping damage If you have any questions please contact your representative as soon as possible Transmitter Transducers Accessories Documents Pipe Straps Screw Driver Coupling compound Toolbox Cables Software 4 20mA Signal Cable Satchel Tape Charge 1 Instruction Manual 2 Packing List 3 Certified 3 Point Factory Calibration 4 Applicati...
Page 4: ...ucers 13 4 1 1 Transducer Spacing 13 4 1 2 Transducer Mounting Methods 13 4 1 3 V Method 13 4 1 4 Z Method 14 4 1 5 N Method not commonly used 14 4 2 Transducer Mounting Inspection 14 4 2 1 Signal Strength 14 4 2 2 Signal Quality Q value 15 4 2 3 Total Time and Delta Time 15 4 2 4 Transit Time Ratio 15 Warnings 15 5 Operating Instructions 16 5 1 Connecting the panel personal computer 16 5 2 Establ...
Page 5: ...lysis and Printing 29 5 12 2 4 Configuration Information Display 30 5 12 2 5 Menu Functions 31 5 13 Analog Voltage Output 31 5 14 Date and Time Settings 31 5 15 Check Flow of Every Day Month Year 32 5 16 Automatic Flow Correction 32 5 17 Working Timer 32 5 18 Manual Totalizer 32 5 19 Analog Output Calibration 32 5 20 ESN 32 6 Windows Display Explanations 33 6 1 Windows Display Codes 33 6 2 Display...
Page 6: ...hicknesses 66 9 10 Cast Iron Pipe Data 66 9 11 Ductile Iron Pipe Data 67 9 12 Sound Speeds In Various Fluids 68 9 13 Sound Speed in Various Pipe Materials 77 10 Appendix 78 10 1 Install Flowmeter Software on TPC 78 10 2 UFM Data Installation 80 10 2 1 Hardware requirements 80 10 2 2 OS Requirements 80 10 2 3 Installing Method 80 Update Information __________________________________________________...
Page 7: ...y can be connected through the battery recharge port on the panel 1 2 2 Connecting The Wiring Open the hinged front cover of the electronics Shown from left to right on the panel of the PORTABLE are the battery recharge port charge the transmitter or connect to the standby power supply power switch power light red run indicator green upstream transducer connector downstream transducer connector ou...
Page 8: ...d the short cut keyTPC area a Identification area Software logo Site Lab SL1188P b Information display area WARNING When the battery power is less than 15 use time is less than 40 seconds the power indicator light will change to orange Note Turn off the cell phone function during the meter measurement and setting Run the flow meter procedure in the panel personal computer Please turn to the instru...
Page 9: ...urement displays are subdivided into more than 100 independent menus The operator can input parameters modify settings or display measurement results by visiting a specific menu These menus are arranged by 2 digit serial numbers from 00 99 then using 0 1 etc Each menu ID code has a defined meaning For example menu 11 is the pipe outside diameter while menu 25 is the mounting spacing between the tr...
Page 10: ...sword has to be set by the user 1 6 Flowmeter Menu Descriptions Menus are assigned as follows 00 09 Display menus Used to display flow rate positive total negative total net total velocity date time etc 10 29 Setup menus Used to enter pipe outer diameter pipe wall thickness fluid type transducer type transducer mounting and spacing etc 30 38 Flow units selection and totalizer operating menus Used ...
Page 11: ... drop down menu then press the ENT key Pipe Material 14 0 Carbon Steel Step 4 Liner material parameters including thickness and sound velocity if needed Press the Menu 1 6 key to enter menu 16 press the ENT key use the or key to select liner material from the drop down menu then press the ENT key Liner Material 16 0 None No Liner Step 5 Fluid type Press the Menu 2 0 key to enter menu 20 press the ...
Page 12: ...y to select transducer mounting from the drop down menu then press the ENT key Transducer Mounting 0 V Step 8 Adjust Transducer spacing Press the Menu 2 5 key to enter menu 25 accurately install the transducer according to the displayed transducer mounting spacing and the selected mounting method Refer to Installing the Transducers in this chapter Transducer Spacing 159 86 mm ...
Page 13: ...hat is always full of liquid such as a vertical pipe with flow in the upward direction or a full horizontal pipe Ensure enough straight pipe length at least equal to the figure shown below for the upstream and downstream transducers installation Pump Valve Reduce Diffuser Tee 90o bend Straight length of downstream piping Straight length of upstream piping Name Detector 10D min 0 5D min L 5D L 5D L...
Page 14: ...symmetrically due to limitation of the local installation conditions it may be necessary to mount the transducers at a location where there is a guaranteed full pipe condition the pipe is always full of liquid 4 1 1 Transducer Spacing After entering the required parameters the spacing between the ENDS of the two transducers is considered as the standard transducer spacing Refer to Top View on tran...
Page 15: ...e confirmed by checking the detected signal strength total transit time delta time as well as transit time ratio These checks are explained below The mounting condition directly influences the flow value accuracy and system reliability In most instances apply a wide bead of sonic coupling compound lengthwise on the face of the transducer and stick it to the outside pipe wall to get good measuremen...
Page 16: ...meter wall thickness pipe material liner etc have been entered correctly 2 If the transducer mounting spacing is accordance with the display in menu 25 3 If the transducer is mounted at the pipe s centerline on the same diameter 4 If the scale is too thick or the pipe mounting is distorted in shape etc Warnings Pipe parameters entered must be accurate otherwise the flowmeter will not work properly...
Page 17: ... normally Press OK and enter the main interface press Comm to check whether the connection is correct or not OK means normal connection Failure means not Misoperation will cause the panel personal computer system halted no response please logout the software press backspace key to return to desktop Please refer to the panel personal computer operation instruction for more details Picture 5 1 logou...
Page 18: ...le ends are keyed to fit into the transducers wiring connection and then fastened with a circular connector The opposite end is a circular connector plug that simply inserts into the corresponding Upstream and Downstream connection point Once these 2 cables are securely connected you are ready to read the flow MATING As drawing shows hold the smooth part in back of the plug and push when the key o...
Page 19: ... spacing displayed in MENU25 may be less than 7 5 190mm then we can install the transducers in single slide ruler rack The installation method is unscrewing a transducer off the rack at first then install the two transducers to one rack face to face The flow meter will now work as usual Exercise caution during this procedure as the transducers are spring loaded in the racks ...
Page 20: ...ow or an Upstream Downstream Identification Additionally each rack has the flow direction arrow depicted on it Ensure the arrows point in the correct direction to ensure proper operation Once the cables are connected simply select MENU 00 and you will display the flow rate You can then use the shortcut keys for additional flow information as desired NOTE The 2 transducers must be fixed at the fron...
Page 21: ...program that set point into the instrument If the zero set point is not at true zero flow an offset will occur For an ultrasonic Flowmeter the measurement difference from zero point cannot be ignored at low flow It is necessary to perform a zero set calibration to improve low flow measurement accuracy 5 6 Scale Factor Scale factor refers to the ratio between actual value and reading value For exam...
Page 22: ...M78 and M79 For example if it is necessary to transmit the positive Totalizer pulse through a relay and each pulse represents a flow of 0 1m3 the configuration is as follows In Window M33 select Totalizer the flow unit Cubic Meters m3 In Window M34 select the scale factor x0 1 In Window M79 select 9 Positive Totalizer pulse output ATTENTION Make sure to select a suitable Totalizer pulse since the ...
Page 23: ...ocess The setup guide greatly simplifies the operation of the meter allowing personnel who are unfamiliar with the Flowmeter to configure its settings easily Full Screen Display The program has the ability to display MENU00 04 and shortcut keys Flow Velo Total Total in full screen view Operators can check the data easily 5 12 1 Data Acquisition and Analysis 5 12 1 1 TPC Data Acquisition and Analys...
Page 24: ...ocity are displayed on the screen in real time each of them distinguished by different colors If a curve exceeds the display range of the coordinate it will be readjusted to be within the optimal display area If necessary you can also adjust it manually using a multiplier File Name Give a name for the collected data Input the name above the line manually otherwise the name will be generated automa...
Page 25: ...buttons below the main page Load Analyze and Graph These buttons are used for loading data file data analysis and graph display respectively Load page Press Load button to enter the Load page After clicking a file and pressing the OK button the contents of the selected file are displayed in a table You can delete data files from this page by selecting a file and pressing the Delete button Analyze ...
Page 26: ...ve names that the boxes indicate You can adjust the display area of a curve by using a multiplier The time below the coordinate shows the time range of the curve currently displayed on the screen You can browse through the page using Left Right arrow button or move data points using Left Right triangle button When clicking a point within the graph display area a cursor intersecting with the curve ...
Page 27: ...d date and the last four digit indicate the current time Such as 10260955 indicates the current time is Oct 26th 9 55am The file will be saved as TXT format Interval time the interval time for the data acquisition There are 2S 10S 30S 60S 4 options to select Time of Acquisition the time of acquisition for the data Input by the users Unit min Factory default is 120 min Start click Start to start th...
Page 28: ...users to display graphs print or save the files in Excel format or browse and analyze the collected data in a table enabling users to manage the Flowmeter data more conveniently Flowmeter data are stored under the Flowmeter directory of the TPC You can set the TPC to Driver Mode and connect it with your PC The main window of this program is divided up into 4 pages Data page Graph page Analyze page...
Page 29: ... sec 30 sec and 60 sec The default unit is 2 sec When a time unit other than 2 sec is selected the data in the table will be displayed and printed according to the selected time interval Below the data table the File text box shows the File Path Rec shows the number of the data and Time shows the time range for data acquisition The contents of the data table are date time flow rate flow velocity n...
Page 30: ...nate will be changed accordingly Time Used to change range of the time scale 1mul stands for 50 sec per scale 2mul for 25 sec 5mul for 10 sec and 10mul for 5sec Once it is changed the curve displayed on the horizontal ordinate will be changed accordingly Reset button Press to restore the colors of the curves into defaults Print button Press to print the graph At the bottom of the page the File tex...
Page 31: ... 0 Page 30 of 81 5 12 2 4 Configuration Information Display This page displays the configuration information of the Flowmeter This page cannot be printed Flowmeter Serial Number Displays Flowmeter serial number Fluid Type Displays fluid type being measured ...
Page 32: ... Paper Direction etc Print Preview Previews the printing contents the Edit submenu has the following functions Copy Copies the selected region Find Searches the data in the report the Help submenu has the following functions Help Operating instructions for this software About Software copyright version information and so on 5 13 Analog Voltage Output Connect a 250Ω resistance to the current loop i...
Page 33: ...at working day To read the total flow of a month press Menu 8 2 key and select sub item No 1 Month To read the total flow of a year press Menu 8 2 key and select sub item No 2 Year 5 16 Automatic Flow Correction In Window M83 select Yes the lost flow during an offline session will be automatically recovered into the flow Totalizer as soon as the next power on Select No to neglect this function 5 1...
Page 34: ...its Options 30 Measurement Units 31 Flow Rate Units 32 Totalizer Units 33 Totalizer Multiplier 34 Net Totalizer 35 POS Totalizer 36 NEG Totalizer 37 Totalizer Reset 38 Manual Totalizer Setup Options 40 Damping 41 Low Flow Cutoff Value 42 Set Zero 43 Reset Zero 44 Manual Zero Point 45 Scale Factor 47 System Lock Input and output setup 55 CL Mode Select 56 CL 4mA Output Value 57 CL 20mA Output Value...
Page 35: ...en turned off the positive Totalizer value displayed is the total prior to its turn off Flow 0 1129m3 h R POS 0x1m3 Menu 0 3 Flow Rate Negative Totalizer Display flow rate and negative Totalizer Select the negative Totalizer value in Window M31 If the negative Totalizer has been turned off refer to M36 the value displayed is the total prior to turn off Flow 0 1120m3 h R NEG 0x1m3 Menu 0 4 Date Tim...
Page 36: ...ntered press to skip this window Note Enter either pipe wall thickness or pipe inside diameter Pipe Inner Diameter 52 mm Menu 1 4 Pipe Material Enter pipe material The following options are available by buttons or numerical keys 0 Carbon Steel 1 Stainless Steel 2 Cast Iron 3 Ductile Iron 4 Copper 5 PVC 6 Aluminum 7 Asbestos 8 Fiber Glass Epoxy 9 Other Refer to item 9 Other it is possible to enter ...
Page 37: ... item Other in Window M16 is selected Liner Sound Velocity 2270 m s Menu 1 8 Liner Thickness Enter liner thickness It only can be visited when a definite liner is selected in Window M16 Liner Thickness 18 10 mm Menu 2 0 Select Fluid Type The following options are available 0 Water 1 Sea Water 2 Kerosene 3 Gasoline 4 Fuel Oil 5 Crude Oil 6 Propane 45 7 Butane 0 8 Other 9 Diesel Oil 10 Castor Oil 11...
Page 38: ...o the transducer spacing displayed be sure that the transducer spacing must be measured precisely during installation The system will display the data automatically after the pipe parameter had been entered Transducer Spacing 62 7327 mm Menu 2 6 Initial Parameter Setups and Save Load and save the parameters 18 different sets of setup conditions groups are available to load and save by three method...
Page 39: ...fy a value When the signal quality falls below this value the measurement stops automatically If the flow meter is already able to stop measuring when the pipe is empty a value in the range of 30 to 40 should also be entered in this window to ensure no measurement when the pipe is empty It should be understood that the instrument is NOT designed to function correctly on an empty pipe Empty Pipe Se...
Page 40: ...001 1E 3 1 X0 01 2 X0 1 3 X1 4 X10 5 X100 6 X1000 7 X10000 1E 4 Factory default factor is x1 Totalizer Multiplier 0 x0 001 1E 3 Menu 3 4 ON OFF Net Totalizer On off net Totalizer ON indicates the Totalizer is turned on while OFF indicates it is turned off When it is turned off the net Totalizer displays in Window M00 will not change Factory default is ON Net Totalizer 34 ON Menu 3 5 ON OFF POS Tot...
Page 41: ...ficient increases the stability However the measurement displayed may be slightly delayed due to over damping Logging too long may result in no response to real time fluctuation especially when flow rate fluctuates wildly Therefore damping should be kept at a minimum and increased just enough to reduce the fluctuation to an acceptable degree by 3 to 10 seconds The damping factor ranges from 0 999 ...
Page 42: ...w to be displayed as 0 If so it can be recovered via Window M43 Set Zero 42 Press ENT to go Menu 4 3 Reset Zero Select YES reset Zero Point which was set by the user Reset Zero 43 NO Menu 4 4 Manual Zero Point This method is not commonly used It is only suitable for experienced operators to set zero under conditions when it is not preferable to use other methods Enter Manual Zero Point 44 0 m3 h t...
Page 43: ...A Fluid Fluid Velocity Velocity 24mA Fluid velocity Output current 20mA 4mA The Serial Port controls the output according to the command and parameter entered in the RS232 to output a definite current value through the current loop The command formats are narrated in the command explanations to Serial Port controls For example if it is necessary to output a 6mA current through the current loop it ...
Page 44: ...with the displayed values It is necessary to re calibrate the CL if over the permitted tolerance For more information refer to Analog Outputs Calibration CL Checkup 58 Press ENT WhenReady Menu 5 9 CL Current Output Display CL current output The display of 10 0000mA indicates that CL current output value is 10 0000mA If the difference between displaying value and CL output value is too large the cu...
Page 45: ...rner of the screen indicates that it was working properly the whole day On the contrary if G is displayed it indicates that the instrument gain was adjusted at least once Probably it was offline once on that day If H is displayed it indicates that poor signal was detected at least once Also it indicates that the operation was interrupted or problems occurred in the installation Date Totalizer 82 0...
Page 46: ...entered in Window M21 or improper installation of the transducers Fluid Sound Velocity 1443 4 m s Menu 9 3 Total Time and Delta Time Display the measured ultrasonic average time unit nS and delta time of the upstream and downstream unit nS time The velocity calculation in the Flowmeter is based on the two readings The delta time is the best indication that the instrument is running steadily Normal...
Page 47: ...isplay the last flow rate Last Flow Rate 3 100 43 m3 h Menu 4 Total ON OFF Times Display total on off times since the Flowmeter left the factory ON OFF Times 4 40 Menu 5 Calculator This window works as a calculator with an internal calculation function To use the calculator enter the first parameter X select a calculating operator if there is a second parameter enter it as parameter Y then combine...
Page 48: ... chapter 5 for error code contents Error Code 1 Comm Shortcut Key for Communication Setup Display the communication condition between the TPC and the Flowmeter This window Display OK if the connection has been made correctly If not it displays Failure and you should check the Bluetooth Communications Under normal conditions you should not conduct detection repeatedly using this button otherwise yo...
Page 49: ... for self diagnostics once again to detect and solve possible errors using the table below If a problem still exists please contact the factory or the factory s local representative for assistance Table 2 applies when errors caused by incorrect settings and signals are detected and are announced by error codes displayed in Window M08 7 1 Table 1 Self diagnoses and Error Solutions upon power on LCD...
Page 50: ...ty Poor signal quality All reasons are included in the above mentioned causes Solution refers to above mentioned solutions E Current Loop over 20mA No influence normally Ignore it if no current output is being used 4 20mA current loop over 120 Improper settings to current loop output Check settings refer to Window M56 and confirm if actual flow is too high Q Frequency output over set value No infl...
Page 51: ...and sound wave transmission is not possible because of the a layer of scale between the transducers and pipe inside wall Question Why is there no CL current loop output Answer Check if the desired current output mode is set in Window M55 See if the CL is powered off by CL Off settings Open the electronics enclosure to inspect the hardware circuit Check to see if the short circuit terminal near ter...
Page 52: ...be selected to meet customer s requirements Daily monthly and yearly totalized flow Totalized flow for the last 64 days and months as well as for the last 5 years are may be viewed You can be convenient to use the high capacity memorized SD card for long time data logging on the scene Clear user friendly operating interface The fully windowed software supplied with this instrument allows users to ...
Page 53: ...e operation and maintenance Energy economy supervision and water conservation management Pulp and paper Pipeline leak detection Regular inspection tracking and collection Energy measuring and balance Network monitoring systems and energy flow computer management 8 5 Specifications Performance Flow range 0 40 ft s 0 12 m s Accuracy 0 5 of measured value Repeatability 0 15 Pipe size Clamp on 1 200 2...
Page 54: ...12 Acetone 1190 Carbine 1121 Ethanol 1168 Alcohol 1440 1 5 Glycol 1620 Glycerin 1923 1180 Gasoline 1250 0 80 Benzene 1330 Toluene 1170 0 69 Kerosene 1420 2 3 Petroleum 1290 Retinal 1280 Aviation kerosene 1298 Peanut oil 1472 Castor oil 1502 9 2 Sound Velocity for Various Materials Commonly Used Pipe Material Sound Velocity m s Steel 3206 ABS 2286 Aluminum 3048 Brass 2270 Cast iron 2460 Bronze 2270...
Page 55: ...515 7 34 1517 7 35 1519 7 36 1521 7 37 1523 5 38 1525 3 39 1527 1 40 1528 8 41 1530 4 42 1532 0 43 1533 5 44 1534 9 45 1536 3 46 1537 7 47 1538 9 48 1540 2 49 1541 3 50 1542 5 51 1543 5 52 1544 6 53 1545 5 54 1546 4 55 1547 3 56 1548 1 57 1548 9 58 1549 6 59 1550 3 60 1550 9 61 1551 5 62 1552 0 63 1552 5 64 1553 0 65 1553 4 66 1553 7 67 1554 0 68 1554 3 69 1554 5 70 1554 7 71 1554 9 72 1555 0 73 1...
Page 56: ...hyde 1180 Glycol 1620 Glycerin 1923 1180 Gas 1250 0 80 66 Gas 1171 80 Gas 1139 0 Gas 1385 Benzene 1330 Methylbenzene 1340 Toluene 1170 0 69 Tetra chloromethane 938 Kerosene 1420 2 3 Petroleum 1290 Pine oil 1280 Chloroethylene 1050 0 82 Dagang jet fuel 1298 Daqing 0 jet fuel 1290 Arachis oil 1472 Castor oil 1502 9 5 Sound Velocity of Common Materials Pipe Material Sound Velocity m s Steel 3206 ABS ...
Page 57: ...8 190 4 1 551 5 089 89 192 2 1 551 5 089 90 194 0 1 550 5 086 91 195 8 1 549 5 082 92 197 6 1 549 5 082 93 199 4 1 548 5 079 94 201 2 1 547 5 076 Temperature Sound Speed in Water 95 203 0 1 547 5 076 96 204 8 1 546 5 072 97 206 6 1 545 5 069 98 208 4 1 544 5 066 99 210 2 1 543 5 063 100 212 0 1 543 5 063 104 220 0 1 538 5 046 110 230 0 1 532 5 026 116 240 0 1 524 5 000 121 250 0 1 526 5 007 127 26...
Page 58: ...109 0 622 1 2 0 840 XS 80 80S 0 147 0 546 1 2 0 840 160 0 188 0 464 1 2 0 840 XX 0 294 0 252 3 4 1 050 5 5S 0 065 0 920 3 4 1 050 10 10S 0 083 0 884 3 4 1 050 STD 40 40S 0 113 0 824 3 4 1 050 XS 80 80S 0 154 0 742 3 4 1 050 160 0 219 0 612 3 4 1 050 XX 0 308 0 434 1 1 315 5 5S 0 065 1 185 1 1 315 10 10S 0 109 1 097 1 1 315 STD 40 40S 0 133 1 049 1 1 315 XS 80 80S 0 179 0 957 1 1 315 160 0 250 0 81...
Page 59: ... 2 875 XX 0 552 1 771 3 3 500 5 5S 0 083 3 334 3 3 500 10 10S 0 120 3 260 3 3 500 STD 40 40S 0 216 3 068 3 3 500 XS 80 80S 0 300 2 900 3 3 500 160 0 438 2 624 3 3 500 XX 0 600 2 300 31 2 4 000 5 5S 0 083 3 834 31 2 4 000 10 10S 0 120 3 760 31 2 4 000 STD 40 40S 0 226 3 548 31 2 4 000 XS 80 80S 0 318 3 364 31 2 4 000 XX 0 636 2 728 4 4 500 5 5S 0 083 4 334 4 4 500 10 10S 0 120 4 260 4 4 500 0 156 4...
Page 60: ...40 40S 0 301 7 023 7 7 625 XS 80 80S 0 500 6 625 7 7 625 XX 0 875 5 875 8 8 625 5S 0 109 8 407 8 8 625 10 10S 0 148 8 329 8 8 625 20 0 250 8 125 8 8 625 30 0 277 8 071 8 8 625 STD 40 40S 0 322 7 981 8 8 625 60 0 406 7 813 8 8 625 XS 80 80S 0 500 7 625 8 8 625 100 0 594 7 437 8 8 625 120 0 719 7 187 8 8 625 140 0 812 7 001 8 8 625 XX 0 875 6 875 8 8 625 160 0 906 6 813 9 9 625 STD 40 40S 0 342 8 94...
Page 61: ...0 500 11 750 12 12 750 60 0 562 11 626 12 12 750 80 0 688 11 374 12 12 750 100 0 844 11 062 12 12 750 120 1 000 10 750 12 12 750 140 1 125 10 500 12 12 750 160 1 312 10 126 14 14 000 10S 0 188 13 624 14 14 000 10 0 250 13 500 14 14 000 20 0 312 13 376 14 14 000 STD 30 40S 0 375 13 250 14 14 000 40 0 438 13 124 14 14 000 XS 80S 0 500 13 000 14 14 000 60 0 594 12 812 14 14 000 80 0 750 12 500 14 14 ...
Page 62: ...8 18 18 000 120 1 375 15 250 18 18 000 140 1 562 14 876 18 18 000 160 1 781 14 438 20 20 000 10S 0 218 19 564 20 20 000 10 0 250 19 500 20 20 000 STD 20 40S 0 375 19 250 20 20 000 XS 30 80S 0 500 19 000 20 20 000 40 0 594 18 812 20 20 000 60 0 812 18 376 20 20 000 80 1 031 17 938 20 20 000 100 1 281 17 438 20 20 000 120 1 500 17 000 20 20 000 140 1 750 16 500 20 20 000 160 1 969 16 062 22 22 000 1...
Page 63: ... 375 27 250 28 28 000 20 80S 0 500 27 000 28 28 000 30 0 625 26 750 30 30 000 10 0 312 29 376 30 30 000 STD 40S 0 375 29 250 30 30 000 XS 20 80S 0 500 29 000 30 30 000 30 0 625 28 750 32 32 000 10 0 312 31 376 32 32 000 STD 0 375 31 250 32 32 000 20 0 500 31 000 32 32 000 30 0 625 30 750 32 32 000 40 0 688 30 264 34 34 000 10 0 312 33 376 34 34 000 STD 0 375 33 250 34 34 000 20 0 500 33 000 34 34 ...
Page 64: ... 65 73 0 5 2 STD 40 2 65 73 0 7 0 XS 80 2 65 73 0 9 5 160 2 65 73 0 14 0 XXS 3 80 88 9 5 5 STD 40 3 80 88 9 7 6 XS 80 3 80 88 9 11 1 160 3 80 88 9 15 2 XXS 3 90 101 6 5 7 STD 40 3 90 101 6 8 1 XS 80 4 100 114 3 6 0 STD 40 4 100 114 3 8 6 XS 80 4 100 114 3 11 1 120 4 100 114 3 13 5 160 4 100 114 3 17 1 XXS 5 125 141 3 6 6 STD 40 5 125 141 3 9 5 XS 80 5 125 141 3 12 7 120 5 125 141 3 15 9 160 5 125 ...
Page 65: ... 9 28 6 140 12 300 323 9 33 3 160 14 350 355 6 6 4 10 14 350 355 6 7 9 20 14 350 355 6 9 5 STD 30 14 350 355 6 11 1 40 14 350 355 6 12 7 XS 14 350 355 6 15 1 60 14 350 355 6 19 0 80 14 350 355 6 23 8 100 14 350 355 6 27 8 120 14 350 355 6 31 8 140 14 350 355 6 35 7 160 16 400 406 4 6 4 10 16 400 406 4 7 9 20 16 400 406 4 9 5 STD 30 16 400 406 4 12 7 XS 40 16 400 406 4 16 7 60 16 400 406 4 21 4 80 ...
Page 66: ...10 0 6 4 10 24 600 610 0 9 5 STD 20 24 600 610 0 12 7 XS 24 600 610 0 14 3 30 24 600 610 0 17 5 40 24 600 610 0 24 6 60 24 600 610 0 31 0 80 24 600 610 0 38 9 100 24 600 610 0 46 0 120 24 600 610 0 52 4 140 24 600 610 0 59 5 160 26 650 660 0 7 9 10 26 650 660 0 9 5 STD 26 650 660 0 12 7 XS 20 28 700 711 0 7 9 10 28 700 711 0 9 5 STD 28 700 711 0 12 7 XS 20 28 700 711 0 15 9 30 30 750 762 0 7 9 10 ...
Page 67: ...0 1 8 26 35 527 1 4 52 61 1052 9 10 Cast Iron Pipe Data Class A Class B Class C Class D Nominal Pipe Size in Outside Diameter in Wall Thickness in Outside Diameter in Wall Thickness in Outside Diameter in Wall Thickness in Outside Diameter in Wall Thickness in 3 3 80 0 39 3 96 0 42 3 96 0 45 3 96 0 48 4 4 80 0 42 5 00 0 45 5 00 0 40 5 00 0 52 6 6 90 0 44 7 10 0 48 7 10 0 51 7 10 0 55 8 9 05 0 46 9...
Page 68: ...54 1 27 23 02 1 39 23 02 1 51 24 26 90 1 31 26 90 1 45 27 76 1 75 27 76 1 88 30 33 10 1 55 33 46 1 73 32 39 60 1 80 40 04 2 02 42 48 54 60 72 84 9 11 Ductile Iron Pipe Data Pipe Wall Thickness in Nominal Pipe Size in Outside Diameter in Class50 Class51 Class52 Class53 Class54 Class55 Class56 3 3 96 0 25 0 28 0 31 0 43 0 37 0 40 4 4 80 0 26 0 29 0 32 0 35 0 38 0 41 6 6 90 0 25 0 28 0 31 0 34 0 37 0...
Page 69: ...ol C2H6O 0 789 1207 3960 4 0 1 396 1502 Alkazene 13 C15H24 0 86 1317 43209 3 9 Alkazene 25 C10H12Cl2 1 20 1307 42881 3 4 2 Amino ethanol C2H7NO 1 018 1724 56562 3 4 2 Aminotolidine 46 C7H9N 0 999 20 1618 53084 4 394 20 47297 68 4 Aminotolidine 46 C7H9N 0 966 45 1480 48556 1 863 50 20045 122 Ammonia 35 NH3 0 771 1729 33 56726 27 6 68 0 292 33 3141 27 Amorphous Polyolefin 0 98 962 6 190 31582 374 26...
Page 70: ...61 Cetane 23 C16H34 0 773 20 1338 4389 8 3 71 4 32 46 483 Chloro benezene C6H5Cl 1 106 1273 4176 5 3 6 0 722 7 768 1 Chloro butane 22 26 C4H9Cl 0 887 1140 3740 2 4 57 0 529 15 5 692 59 Chloro diFluoromethane 3 Freon 22 CHClF2 1 491 69 893 9 50 2932 7 58 4 79 Chloroform 47 CHCl3 1 489 979 3211 9 3 4 0 55 5 918 1 Chloro propane 47 C3H7Cl 0 892 1058 3471 1 0 378 4 067 Chlorotrifluorornrthane 5 CClF3 ...
Page 71: ...hylene glycol C4H10O3 1 116 1586 5203 4 2 4 Diethylene glycol Monoethyl ether C6H14O3 0 988 1458 4783 5 Diethylenimide oxide C4H9NO 1 00 1442 4731 3 8 1 2 bis DiFluoramino Butane 43 C4H8 NF2 2 1 216 1000 3280 8 1 2 bis DiFluoramino 2 methylpropane 43 C4H9 NF2 2 1 213 900 2952 8 1 2 bis DiFluoramino propane 43 C3H6 NF2 2 1 265 960 3149 6 2 2 bis DiFluoramino Propane 43 C3H6 NF2 2 1 254 890 2920 2 2...
Page 72: ...0 947 1320 4330 7 0 22 2 367 Fluorine F 0 545 143 403 143 1322 2 225 11 31 Fluoro benzene 46 C6H5F 1 024 20 1189 3900 9 0 584 20 6 238 68 Formaldehyde Methyl ester C2H4O2 0 974 1127 3697 5 4 02 Formamide CH3NO 1 134 20 1622 5321 5 2 2 2 91 31 311 Formic acid amide CH3NO 1 134 20 1622 5321 5 2 91 31 311 Freon R12 774 2 2540 Furfural C5H4O2 1 157 1444 4737 5 3 7 Furfuryl alcohol C5H4O2 1 135 1450 47...
Page 73: ...2 28 20 978 3208 7 0 211 2 27 Lsobutyl acetate 22 C6H12O 1180 27 3871 4 81 4 85 Isobutanol C4H10O 0 81 20 1212 3976 4 Iso Butane 1219 8 4002 Isopentane 36 C5H12 0 62 20 980 3215 2 4 8 0 34 3 658 Isopropanol 46 C3H8O 0 785 20 1170 20 3838 6 68 2 718 29 245 Isopropyl alcohol 46 C3H8O 0 785 20 1170 20 3838 6 68 2 718 29 245 Kerosene 0 81 1324 4343 8 3 6 Ketohexamethylene C6H10O 0 948 1423 4668 6 4 0 ...
Page 74: ...1 207 246 595 246 1952 1 411 Nitrobenzene 46 C6H5NO2 1 204 20 1415 20 4642 4 68 1 514 16 29 Nitrogen 45 N2 0 808 199 962 199 3156 2 328 0 217 199 2 334 326 Nitromethane 43 CH3NO2 1 135 1300 4265 1 4 0 0 549 5 907 Nonane 23 C9H2O 0 718 20 1207 3960 4 04 0 99 20 10 652 68 1 Nonene 27 C9H18 0 736 20 1207 3960 4 0 Octane 23 C8H18 0 703 1172 3845 1 4 14 0 73 7 857 n Octane 29 C8H18 0 704 20 1212 5 3978...
Page 75: ...2 Phthalardione C8H4O3 1125 152 3691 306 Phthalic acid anhyaride C3H4O3 1125 152 3691 306 Pthalic anhyaride C8H4O3 1125 152 3691 306 Pimelic ketone C6H10O 0 948 1423 4668 6 4 0 Plexiglas Lucite Acrylic 2651 8698 Polyterpene Resin 0 77 1099 8 190 3608 4 374 39 000 419 500 Potassium bromide 42 KBr 1169 900 3835 3 1652 0 71 715cp 900 7 693 1652 Potassium fluoride 42 KF 1792 900 5879 3 1652 1 03 Potas...
Page 76: ...877 2082 1000 6830 7 1832 1 32 Sodium nitrate 48 NaNO3 1 884 336 1763 3 336 5785 1 637 0 74 1 37 336 14 74 637 Sodium nitrite 48 NaNO2 1 805 292 1876 8 292 6157 5 558 Solvesso 3 0 877 1370 4494 8 3 7 Spirit of wine C2H6O 0 789 1207 3960 4 0 1 396 15 02 Sulfur 7 8 10 S 1177 250 3861 5 482 1 13 Sulfuric Acid 1 H2SO4 1 841 1257 6 4126 1 43 11 16 120 081 Tellurium 7 Te 991 450 3251 3 842 0 73 1 1 2 2 ...
Page 77: ... 47 Triethylene glycol C6H14O4 1 123 1608 5275 6 3 8 1 1 1 Trifluoro 2 Chloro 2 Bromo Ethane C2HClBrF3 1 869 693 2273 6 1 2 2 Trifluorotrichloro ethane Freon 1 13 CCl2F CClF2 1 563 783 7 0 2571 2 32 3 44 d 1 3 3 Trimethylnorrcamphor C10H16O 0 947 1320 4330 7 0 22 2 37 Trinitrotoluene 43 C7H5 NO2 3 1 64 1610 81 5282 2 178 Turpentine 0 88 1255 4117 5 1 4 15 064 Unisis 800 0 87 1346 4416 Water distil...
Page 78: ...nealed 2325 7628 Copper rolled 2270 7448 CuNi 70 Cu 30 Ni 2540 8334 5 03 0 1980 CuNi 90 Cu 10 Ni 2060 6759 4 01 0 1579 Brass Naval 2120 6923 4 43 0 1744 Gold hand drawn 1200 3937 3 24 0 1276 Inconel 3020 9909 5 82 0 2291 Iron electrolytic 3240 10630 5 90 0 2323 Iron Armco 3240 10630 5 90 0 2323 Ductile Iron 3000 9843 Cast Iron 2500 8203 4 55 0 1791 Monel 2720 8924 5 35 0 2106 Nickel 2960 9712 5 63...
Page 79: ...lication according to the clue Note Please ensure that the SL1188P apk and Dctp pdb file are put under the SD kagan catalogue Data DCIM mnt sdcard Aldiko Android SL1188P apk Dctp pdb 168KB 1KB Allow this application to Do you want to install this application Install Cancel Storage Modify delete SD card contents Network communication Create Bluetooth connections System tools Bluetooth administratio...
Page 80: ...ange Select the suitable device to connect and in the event that a data window appears asking for a password enter the password of 1234 This will unlock the unit and allow communications to proceed OK means successful connection SL1188P Key Pad Flow Config 1 4 7 0 Signal 3 6 9 Error 2 5 8 Aout Menu ENT Comm Communication Setup OK FLOW1238 FLOW0453 SL1188P Key Pad Flow Config 1 4 7 0 Signal 3 6 9 E...
Page 81: ...8SE 4 10 2222A or later IE4 01 or later 10 2 3 Installing Method Step 1 Open Setup file in the UFM Data directory to enter installation page Click Next to proceed Step 2 Select an installation directory Click Next to accept the default directory If you want to change the installation directory click Browse to select a directly and click next to continue to the next step Step 3 Select a program fol...
Page 82: ...SL1188P Ultrasonic transit time flowmeter Revision 2 0 0 Page 81 of 81 Step 4 Click Finish to finish installation ...