STCU DS1 

Reading master with display for 

M-Bus devices

Summary of Contents for STCU DS1

Page 1: ...User Manual STCU DS1 Reading master with display for M Bus devices ...

Page 2: ......

Page 3: ...TERISTICS 4 PRODUCT CODE 4 RELATED PRODUCTS 5 CONFORMITY TO REGULATION STANDARDS 5 SUPPORTED DEVICES 5 FRONT PANEL TERMINAL BOX AND CONNECTION DIAGRAMS 6 FRONT PANEL DESCRIPTION 6 TERMINAL BOX DESCRIPTION 6 INSTALLATION AND TESTING 7 M BUS WIRING 7 USE 8 KEYPAD 8 SETTINGS MENÙ 8 DEVICE SEARCH MENÙ 8 BRIGHTNESS MENÙ 9 ...

Page 4: ...ted against overload and short circuits Reporting of an overload in the M Bus line Different models for readings for up to 60 120 or 250 devices expandable up to 500 by means of STAM amplifiers FUNCIONAL SPECIFICATIONS Meter and or device reader with M Bus interface Display for the configuration and visualization of the reading values The possibility of reading the device s instantaneous values by...

Page 5: ...ON STANDARDS Low Voltage Directive EMC Directive SUPPORTED DEVICES Currently the following meters are supported Manufacturer Model Zenner ZELSIUS MULTIDATA S1 MULTIDATA WR3 IZM 972 MULTIPULSE ZELSIUS C5 EngelMann SensoStar 2C US SensoStar 2 Actaris Integral V MaXX AR Therm Excelsius Siemens WFN 21 e WFH 21 AEW 310 2 UH 50 WFN 532 Relay Padpulse M2 Qundis G20 IME CE4DT1 M Bus Apator ELF Socomec Cou...

Page 6: ...L DESCRIPTION LCD Display Keypad USB Interface Connector TERMINAL BOX DESCRIPTION Device Power Supply PE Ground AC 230VAC 50Hz Power Supply AC 230VAC 50Hz Power Supply Communication port with the M Bus network M Bus PE M Bus shielded cable do not connect to ground M Bus ...

Page 7: ...e list of devices see chapter Device Search Menu M BUS WIRING For the M Bus wiring refer to EN13757 2 Annex E M Bus Cable installation and standards relating to the wiring of buildings To connect the meters to the master via the M Bus network we recommend using a twisted cable of at least 2x0 8 mm wires or equivalent JYStY N 2 0 8 mm M Bus cable must not be placed in the same conduit as the power ...

Page 8: ... In this exam ple the selected parameter is Device Search To enter the desired menu just press the Enter key To scroll through the various parameters in the menu just press the Up or Down keys To return to the previous menu press F1 DEVICE SEARCH MENÙ To access this menu from the settings menu position the cursor on Device Search and press the Enter key The search begins as soon as that button is ...

Page 9: ...remains unchanged until a new set up even should the device gets turned off CONTRAST MENÙ To access this menu from the Settings menu select Contrast and press Enter The screen that appears will be like the one here to the left As indicated by the screen press the Up button to increase the value and Down to decrease it Press F1 to save the set parameter and return to the previous menu As with the B...

Page 10: ...ntonio Tomba 15 36078 Valdagno VI ITALY Tel 39 0445 431576 Fax 39 0445 439588 Internet www teleletture it E mail info sitecsrl it Sitec Srl reserves the right to modify this document as necessary without notice in order to adapt it to future developments and or new business needs has prohibited the disclosure although partial if not expressly permitted Also Sitec Srl assumes no liability arising f...