Page 1: ...7 1 0 M I N I S I T THERMOELECTRIC FLAME SUPERVISION DEVICE PRESSURE REGULATOR TEMPERATURE CONTROL SIT Group PIN 0085AQ0287 M U LT I F U N C T I O N A L G A S C O N T R O L ...

Page 2: ...th pilot restart interlock Direct acting thermostat with modulation between minimum maximum setting and on off snap function Pilot gas rate adjuster Pressure regulator optional Built in cutout device to exclude the pressure regulator if necessary Flow adjuster as an alternative to pressure regulator Inlet and outlet pressure test points optional Piezo electric igniter optional The 710 MINISIT is s...

Page 3: ...as inlet 14 Main gas outlet 15 Flange fixing holes M5 16 Fixing points 17 Thermostat bulb 1 Ignition button 2 Shut down button 3 Piezo electric ignition button optional 4 Temperature setting knob 5 Screw for adjusting gas flow to pilot 6 Minimum flow setting screw 7 Maximum flow setting screw versions with flow regulator a b c Thermostat range a b c 8 33 C 3 3 2 13 31 C 2 2 2 13 38 C 3 3 2 13 48 C...

Page 4: ...I O N S G A S F L O W A S A F U N C T I O N O F P R E S S U R E L O S S 0 5 10 Q m3 h d 0 6 4 2 6 p mbar I Family d 0 45 Q 3 9 m3 h p 5 mbar II Family d 0 6 Q 3 5 m3 h p 5 mbar III Family d 1 7 Q 4 4 kg h p 5 mbar ...

Page 5: ...kwise Fig 3 Pilot position Only in those versions with on the knob Turn knob fully clockwise position Shut down Press button right down Fig 4 CAUTION The re start interlock device prevents the appliance from re igniting until the flame supervision device has interrupted the gas flow After this stage i e when the magnet unit has closed it is possible to re ignite the appliance G A S F L O W S E T T...

Page 6: ...m Alternatively it is possible to use a nut and olive connection for Ø 12 mm pipes Codes 0 958 025 and 0 957 007 torque 15 Nm Connection to the pilot burner Ø 4 mm Ø 6 mm or Ø 1 4 pipes can be used Use appropriately sized nut and olive Tighten to 7 Nm torque After making the gas connection check gas seals and efficiency of the appliance A COLORI ...

Page 7: ...w Versions with pressure regulator Remove the safety cap Turn the screw B clockwise to decrease the flow or anticlockwise to increase it WARNING For Minisit operation on third family gases ensure The MIN screw is replaced by a pre drilled version MIN screw as specified by the appliance manufacturer This screw must be screwed fully home The pilot adjusting screw is un screwed two turns from the ful...

Page 8: ...ional control for gas appliances without electrical power supply SIT La Precisa Viale dell Industria 31 33 35129 PADOVA ITALY Tel 049 8293111 Fax 049 8070093 Telex 430130 SITEC I 9 955 881 R01 GRAPHIC DESIGN BY START PD ITALY ...