35
10.4. CONSULTATION - FERTILIZERS
When the irrigation uses fertilizers, we can see all the related infor-
mation on the fertilizer consultation; each fertilizer displays the units
pending application in time and volume of the programs under way.
When a mixer has been installed on the fertilizer, the pre-mixing, op-
erating and pause times pending in the mixer is shown to the right on the
same line (Mx).
If it is doing the last cleaning of fertilizer it shows the remaining time.
If no fertilizers have been configured, the text will read “No existing fertilizers”.
10.5. CONSULTATION - FILTERS
If the equipment has been prepared to manage automatic filter back
cleaning, their status can be checked in this section.
When the filters are being cleaned, a screen is displayed indicating
the filter number the cleaning is being applied to and the time pending
in seconds the cleaning has been activated or the pause between filters to
be make the change.
When cleaning is not being done, we are informed as to the irriga-
tion units that must pass through for the filter to be cleaned again. The
units can be in minutes and/or cubic meters. The meter that reaches zero
first, or also when the sensor measuring differential pressure connected to
the “SC” input is activated, it will start the cleaning and reset the units for
the next cleaning.
The “MALFUNCTIONING” message will be displayed when an error
has occurred in the filters due to continuous cleaning. At this point, the
backcleaning will cease to operate and the system waits for the user to
terminate the stop by entering the section
“Manual
-
Filters”
[8.].
10.6. CONSULTATION - COMMUNICATIONS
For this section, check the manual “Agrónic 2500 Communications Supplement”.
10.7. CONSULTATION - AGRÓNIC
This report is based on values related to the equipment itself. Here the serial number of the “NS” equipment
is found, used for manufacturing report and for identification purposes in communications, as well as the internal
software version (V x.xx) and the type of outputs used, either relay or latch 1 or 2 (impulse), latch x. 2= for 2-
wire solenoids, latch x. 2i= 2-wire with inverted pulse, latch x. 3= 3-wire solenoids.
The “V. Out” indicator informs us if there is voltage in the outputs for
the activation of electrovalve or meters; when there is none, it may be due
to the failure of the external transformer or the internal fuses have been
triggered due to a short circuit.
When the equipment has the option to use a battery charger, it will
be indicated in the “V. Panel” marker if there is any incoming voltage from
the solar panel.
The “Vdc” indicator reads the general power supply voltage of the equipment. In the standard model, this
corresponds to the voltage supplied by the external power supply and in the charger option it reads the voltage in
the battery.
FERTILIZER CONSULTATION
F1: 0000,0 L
M1: 000”
F2: 0087,5 L
M2: 024” ope.
F3: 0000,0 L
F4: 0120,0 L
M4: 000”
Cleaning: 020”
FILTER CONSULTATION
Filter 1 cleaning
Active: 014”
FILTER CONSULTATION
Cleaning stopped
Units between cleanings:
Time: 00063 ’
Volume: 00583 m3
AGRÓNIC CONSULTATION
NS: 00001 V: 1.10 Latch 2i
V.Out .: yes V. Panel: no
Vdc: 12,7 v
Summary of Contents for AGRONIC 2500