ENVIRONMENTAL CONDITIONS

Ambient/storage temperature
Relative humidity
Pollution degree
Overvoltage category
Altitude
Protection

OUTPUT

INPUT

GENERAL

 

 

 

 

 

 

 

 

 

ERPA1-240-F

40

180 - 280

150
400

1,6

5

880

50 - 60

>

0,75

160

0/4-20mA, 0/1-5V DC, 0/2-10V DC or 1k

Ω

 ~ 10kΩ potentiometer. (Device may be damaged at 12V DC and above voltages).

0,2mA (for mA input), 

0,08V (for V input).

0,18mA (for mA input), 

0,075V (for V input).

15ms.

100

Ω

 (for mA input), 

10k

Ω

 (for V input).

Protection feature for reverse connection is available.

ERPA1-xxx-F-xx
90-250V AC, 50/60Hz.
W46 x H110 x D117mm (for ERPA1-x40-F and ERPA1-550-F) , W79 x H120 x D132mm (for ERPA1-570-F).
Approx. 450g (for ERPA1-x40-F and ERPA1-550-F) , Approx. 550g (for ERPA1-570-F) (boxed).
2500 Vrms between I/O terminals for 1 min.
For power line 16mm² cable (with 25mm² cable terminal) cable, for signal line can be connected 4mm² cable.
Max. 1,2Nm.
EN 60947-4-3
Rail mountable (EN60715,TH35 or G-32).
Self extinguishing plastics (According to EN 60695-11-10 V-O).
Fan is controlled with thermostat and works at temperatures over 50°C.

ERPA1-440-F

40

180 - 480

110
290

1,8

8

610

50 - 60

>

0,75

200

ERPA1-550-F

50

180
270

10

720

300

180 - 500

1,8

50 - 60

>

0,75

3A, 250V AC, NO or NC can be selected by program.

ERPA1-570-F

70

400
600

15

4000

400

Order Code
Load Current, AC51/25ºC (Arms)
Load Voltage (Vrms)
Overload Current t=1s/25°C (Arms)
Non rep. Surge current/25°C (Arms)
On-state Voltage Drop (Vrms)
Leakage Current (mArms)
I²t for Fusing t=10ms (A²s)
Frequency (Hz)
Power Factor (Cos

Φ

)

Minimum Operating Current (mArms)
Alarm Output

Input Signal
Transmission Signal
Drop-out Signal
Turn-on Time
Dynamic Input Impedance
Protection

Order code
Power supply
Dimensions
Weight
Isolation Voltage
Connection
Terminal screw torque
Product standard
Mounting
Enclosure material
Fa n (Optional)

                                                                        

ORDER CODE

Thank you for choosing 

ENDA 

ERPA1

 S

eries power regulators.

ERP  A  1 - 5  50 - F - V - RS

ENDA ERPA

Series Power Regulators

Product Basic Code

Rail Mounted    

 ERP

Fan (*)

Fan                              F

Communication

 (*)

RS485 ModBus         RS
Blank (N/A)

Load Voltage

AC                        A

Number of Pole

Single pole

           1

Load Current

40A  AC                      40
50A  AC                      50
70A  AC                      70

Load Voltage

180 - 280V AC      2
180 - 480V AC      4
180 - 500V AC      5 

Please rea this document carefully before using this product. The guarantee will be invalidated if the device is damaged by 
not

 

following instructions detailed in the manual. The company shall not be responsible for any damage or losses

 

however 

caused,

 

which may be experienced as a result of the installation or use of this product.

ERPA1-xxx-

EN-06-210303

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:18

1/4                                                               

ENDA

TM

40 -50 -70A  AC 

L

oad current.

280 -480 -500V  AC 

L

oad voltage.

0/4-20mA, 0/1-5V DC, 0/2-10V DC or 1kΩ ~ 10kΩ 

P

otentiometer input.

4 Digits LED display.
Phase angel or zero-cross controlled.
Soft Start or Kick Start feature.
Overheat alarm output.
Varistor protection for peak voltages.

Vibration coil control (Optional).

RS485 ModBus 

C

ommunication feature (Optional).

CE 

M

arked according to European Norms.

A

A

 

V

V

 

Optional features 

must

 be specified at order.

90% Relative humidity for temperatures up to 20 % °C, decreasing linearly to 50% at 40°C. (Shouldn't be condensation).

-25... +60 °C / -30... +100 °C (Shouldn't be icing and condensation in ambient.)

2
II
Max. 1000m.
IP20 According to EN60529

Vibration

 Control (*)

Vibration Control        V
Blank (N/A)

KEEP AWAY device from exposed to corrosive, volatile and flammable gases or liquids and DO NOT USE the device in similar hazardous locations.

Avoid any liquid contact while the device is switched on. DO NOT clean the device with solvent (thinner, gasoline, acid etc.) and / or abrasive cleaning agents.

*
*
*
*
*
*
*
*
*
*

*

(  )

*

Reviews: