Holding Register 
      Addresses

Decimal

Hex

Data 
Type

Data Content

Parameter 
    Name

Read/Write
Permission

0000d

0001d

0002d

0003d

0004d

0005d

0006d

0007d

0008d

0009d

0010d

0011d
0012d

0013d

0014d

0015d

0016d

0017d

0018d

0019d

0020d

0x0000

0x0001

0x0002

0x0003

0x0004

0x0005

0x0006

0x0007

0x0008

0x0009

0x000A

0x000B

0x000C

0x000D

0x000E

0x000F

0x0010

0x0011

0x0012

0x0013

0x0014

word

word

word

word

word

word

word

word

word

word

word

word
word

word

word

word

word

word

word

word

word

Digital input types .0=

nd

;1=

EA

;2=

SA

;3=

HC

;4=

dF

Set value

Set point upper limit

Upper level alarm

Set point lower limit

Lower level alarm

The offset value for the cooling

Cooling hysteresis

Switch hysteresis for alarm

Type of buzzer sound

Digital input delay

Delay time for the compressor after power is on.

On time for the compressor output in the case of probe failure

Off time for the compressor output in the case of probe failure 

Defrost duration

The time between 2 consecutive defrosts.

Delay time for defrosting after power is on.

After the cooling process of cooling start-up delay

Time delay to display alarm message after alarm is on.

Time delay to display alarm message after power is on.

5Et

uPL

A.uPL

LoL

A.LoL

oFF

Hy5

A.HY5

5nd

d.inp

ddi

C.Pon
C.Fo5

C.PPn

C.PPf

d.dur

d.int

d.dpo

d.drE

A.dfl

A.dpo

1.1 HOLDING REGISTERS

ENDA EDT5411A DIGITAL THERMOSTAT MODBUS PROTOCOL ADDRESS MAP

Delay time required for the compressor to restart following  a stop.

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write
Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

Read / Write

  Input Register 
      Addresses

Decimal

Hex

Data 
Type

Data Content

Read/Write
Permission

0000d

0x0000

word

Measured temperature value (

°

C / 

°

F)

--

1.2 INPUT REGISTERS

Read

Parameter 
    Name

*

 Holding and Input Register parameters of type integer, those “signed integer” is defined as the decimal port of and associated with these  

   parameters. (So,”14.0” is a parameter value of “140” will be read in). Relevant parameters for a period of “mm:ss” type ones in seconds, ”hh:mm”  
   while those species defined in minutes.

  Discrete Input 
      Addresses

Decimal

Hex

Data 
Type

Data Content

Read/Write 
Permission

0000d

0x0000

Bit

Control output status (0=OFF; 1=ON)

--

1.3 DISCRETE INPUTS

Parameter 
    Name

Read

    Coil
Addresses

Decimal

Hex

Data 
Type

00d

0x00

Bit

Control type selection.  OFF = 

Co ,  

ON = 

HE

C.typ

1.4 COILS

01d

0x01

Bit

Temperature unit.  OFF = 

°

C

  ,  ON = 

°

F

Unit

02d

0x02

Bit

Decimal point . OFF=

no  , 

ON=

YE5

D.PNT

03d

0x03

Bit

Digital input polarity. OFF = 

cL  , 

 ON = 

oP

Dpo

04d

0x04

Bit

Smart Defrost selection.   OFF = 

n

o

 ,  ON= 

YE5

D.5mt

Display configuration during defrost.  OFF = 

Lc

  ,  ON = 

rE

D.poN

05d

0x05

Bit

06d

0x06

Bit

Defrost process is started by power-up. OFF = 

no

  ,  ON = 

YE5

A.tYP

07d

0x07

Bit

Alarm configuration.  OFF = 

Ab5

  ,  ON = Relative alarm  

rEF

D.d5p

Data Content

Read/Write 
Permission

Parameter 
    Name

Read / Write
Read / Write
Read / Write
Read / Write

Read / Write
Read / Write

Read / Write

Read / Write

* MODBUS CONNECTION DIAGRAM

1

2

0

 O

h

m

120 Ohm

Master

Slave - 1

Up to 127 slave devices 
can be controlled.

Slave - 2

Slave - 127

-

+

A

B

-

+

A

B

-

+

A

B

-

+

A

B

Termination should be accomplished by 
attaching 120 Ohm resistors to the start 
and at the end of the communication line.

*  Applies to devices with Modbus function.

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:18

ENDA

TM

EDT5411-EN-01-191216

4

/4

Summary of Contents for Enda EDT5411A

Page 1: ...EN60529 Front panel IP65 Rear panel IP20 Supply Voltage 230V AC 110V AC 10 20 50 60Hz 12V AC DC 10 24V AC DC 10 or 9 30V DC 7 24V AC SMPS Power Consumption Max 5VA 2 5mm screw terminal connections 1 4 Digits 12 5mm 7 Segment Red LED Connection Scale Sensitivity Accuracy Time Accuracy Display EMC Safety Requirements EN 61326 1 2013 EN 61010 1 2010 Pollution degree 2 overvoltage category II ELECTRIC...

Page 2: ...specifies that the relay outputs are turned off off state While warning by pressing key audible warning can be temporarily disabled FACTORY SETTINGS If key is held down while the device is powered up d PAr message appears and factory parameters restored FRONT PANEL COMMANDS 1 Viewing and Changing The Set Value Measurement value 30 0 29 9 30 0 1000 24 0 While in Running Mode if key is pressed set v...

Page 3: ...OTE 2 Please specify at order ENDAKEY if required parameter nd d 5mt Smart Defrost selection no Defrost counter between 2 defrost duration decrease irrespective of d int status of the compressor YE5 Defrost counter decreases as long as compressor work No YE5 No baud Adr5 19 20 1 off Modbus slave device address for device MODBUS COMMUNICATION PARAMETERS Modbus communication speed Baud rate 0 oFF 1 ...

Page 4: ...rite Read Write Read Write Input Register Addresses Decimal Hex Data Type Data Content Read Write Permission 0000d 0x0000 word Measured temperature value C F 1 2 INPUT REGISTERS Read Parameter Name Holding and Input Register parameters of type integer those signed integer is defined as the decimal port of and associated with these parameters So 14 0 is a parameter value of 140 will be read in Rele...