ENDA ATF02 Ra
il
Mounted Flasher Analog Timer
*
Can be triggered with supply voltage.
*
Triggering output (OUT1 optional).
*
Contact output for timing function (OUT2).
*
ON and OFF time durations can be adjusted separately.
*
6 Different timing units (S, 10S, M, 10M, H, 10H)
*
Rail mounted.
*
Screw-terminal connection.
*
CE marked according to European Norms.
ATF02 - xR - xV
Power Led
t
on
t
off
t
on
t
off
Power
Power
OUT2 NO
OUT2 Led
90-250V AC
24V AC/DC
Supply Voltage
UV
LV
1 Relay
2 Relays
Output Relay(s)
1R
2R
ORDER CODE
ATF02 - xR - xV
Product Basic Code
Rail Mounted
Analog Timer
OUT1 NO
t on=ON RANGE x ON TIME
t off=OFF RANGE x OFF TIME
1/2
AT
F
02-E-01-201412
0 ... +50°C/-25 ... +70°C (With no condensation and icing).
OUTPUT CONTROL
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah.
Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-
TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Barbaros Cad. No:
18
Thank you for choosing
ENDA AT
F
0
2
R
ail mount
ed
flasher
analog timer.
Technical Specifications
Read this document carefully before using this device. The guarantee will be expired by device demages if you don't
attend to the directions
in
user manual. Also we don't accept any compensations for personal injury, material
damage or capital disadvantages.
Max. humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
ENVIRONMENTAL CONDITIONS
Max. 2000m
IP20, According to EN 60529
Do not use the device in locations subject to corrosive and flammable gasses.
Height
Ambient/storage temperature
Max. relative humidity
Rated pollution degree
ELECTRICAL CHARACTERISTICS
Scale
EMC
İnsulation test voltage
Supply voltage
Power consumption
Connection
Reset time
Accuracy
Safety requirements
90-250V AC +%10 -%20, 50/60Hz or 24V AC %10, 50/60Hz or
±
±
24V DC %10
Max. 10VA
Screw-terminal connection.
Depending on the effect of voltage: max %0.2
EN 61326-1:
2012
EN 61010-1: 2010 (pollution degree 2, overvoltage category II)
3kV AC min. 1 minute, 4,2kV DC min. 1 minute.
Can be adjusted between 0 and 1.
Max. 0.04 seconds.
Depending on the set value settings:max %4.5
Depending on the effect of temperature :max %1
OUTPUTS
Control outputs (OUT1/OUT2)
Control output state
Life expectancy for relays
Relay: 250V AC,
10
A (for resistive load), NO+NC
Without load
1
0.000.000 operation; 250V AC, 10A resistive load
5
0.000 operation.
OUT2 LED lights up for length of ON and blinks for length OFF.
CONTROL
Timing function
Timing unit
ON : ON time duration for relay. OFF : OFF time duration for relay. Can be adjusted on device.
ON and OFF time durations can be selected as, second, 10 seconds, minute, 10 minutes, hours and 10 hours on device.
HOUSING
Mounting
Dimensions
Weight
Enclosure material
Rail mounted (EN 60715, Th35)
W18xH90xD66mm
Approx. 90g (after packaging)
Self extinguishing plastics.
While cleaning the device,solvents (thinner,benzine,acid etc.) or corrosive materials must not be used.
t
t
t
t
t
t