ENDA ATF02 Ra

il

 

Mounted Flasher Analog Timer

*

 Can be triggered with supply voltage.

*

 Triggering output  (OUT1 optional).

*

 Contact output for timing function (OUT2).

   ON  and    OFF  time durations can be adjusted separately.

*

 6 Different timing units (S, 10S, M, 10M, H, 10H)

*

 Rail mounted.

*

 Screw-terminal connection.

*

 CE marked according to European Norms.

ATF02 - xR - xV

Power Led

t

on

t

off

t

on

t

off

Power

Power

OUT2 NO

OUT2 Led

90-250V AC
24V AC/DC

Supply Voltage

UV

LV

1 Relay
2 Relays

Output Relay(s)

1R
2R

ORDER CODE

ATF02 - xR - xV

Product Basic Code
Rail Mounted
Analog Timer

   OUT1 NO

t on=ON RANGE x ON TIME

 

t off=OFF RANGE x OFF TIME

 

 1/2

 AT

F

02-E-01-201412

0 ... +50°C/-25 ... +70°C (With no condensation and icing).

OUTPUT CONTROL

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 

Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-

TURKEY

Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:

18

Thank you for choosing 

ENDA  AT

F

0

2

 

R

ail mount

ed

 

flasher 

analog timer. 

Technical Specifications

Read this document carefully before using this device. The guarantee will be expired by device demages if you don't 
attend  to  the  directions 

in

  user  manual. Also  we  don't  accept  any  compensations  for  personal  injury,  material 

damage or capital disadvantages.  

Max. humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.

ENVIRONMENTAL CONDITIONS

 Max. 2000m

IP20, According to EN 60529 
                                              

 Do not use the device in locations subject to corrosive and flammable gasses.

 Height

 Ambient/storage temperature

 Max. relative humidity

Rated pollution degree

ELECTRICAL CHARACTERISTICS

 Scale

 EMC

 İnsulation test voltage

 Supply voltage
 Power consumption
 Connection

 Reset time

 Accuracy

 Safety requirements

 90-250V AC +%10 -%20, 50/60Hz or 24V AC  %10, 50/60Hz or

±

±

 24V DC  %10

Max. 10VA
Screw-terminal connection.

   Depending on the effect of voltage: max %0.2 

  EN 61326-1: 

 

2012 

  EN 61010-1: 2010 (pollution degree 2, overvoltage category II)

 3kV AC min. 1 minute, 4,2kV DC min. 1 minute.

Can be adjusted between 0 and 1.

Max. 0.04 seconds.

   Depending on the set value settings:max %4.5 
   Depending on the effect of temperature :max %1

OUTPUTS

 Control outputs (OUT1/OUT2)

  Control output state

  Life expectancy for relays

 Relay: 250V AC, 

10

A (for resistive load), NO+NC 

 Without load 

1

0.000.000 operation; 250V AC, 10A resistive load 

5

0.000 operation.

OUT2 LED lights up for length of   ON  and  blinks for length    OFF.

CONTROL

 Timing function 

 Timing unit

  ON : ON time duration for relay.    OFF : OFF time duration for relay. Can be adjusted on device.

ON and OFF time durations can be selected as, second, 10 seconds, minute, 10 minutes, hours and 10 hours on device.

HOUSING

 Mounting
 Dimensions  
 Weight 
 Enclosure material

 Rail mounted (EN 60715, Th35)

 W18xH90xD66mm 

 Approx.  90g (after packaging)

Self extinguishing plastics.

 While cleaning the device,solvents (thinner,benzine,acid etc.) or corrosive materials must not be used.

t

t

t

t

t

t