TENERE PERFORMA B-3D-4D-F-G-S 

 

 
 

1 - Product description 
 

2 - Operating principle  

 
3 – Mounting recommendations 

 
4 - Troubleshooting 

 

5 - Safety instructions 

 

 

SIROCO S.A.S. 

10 rue Jean Rostand - Z.I. 

BP 315 

69745 GENAS Cedex 

Tel: +33 (0)4 78 90 96 96 

Fax: +33 (0)4 78 90 15 98 

www.siroco.fr

 

Summary of Contents for TENERE PERFORMA Series

Page 1: ...ENERE PERFORMA B 3D 4D F G S 1 Product description 2 Operating principle 3 Mounting recommendations 4 Troubleshooting 5 Safety instructions SIROCO S A S 10 rue Jean Rostand Z I BP 315 69745 GENAS Cedex Tel 33 0 4 78 90 96 96 Fax 33 0 4 78 90 15 98 www siroco fr ...

Page 2: ...2 or 3 speeds depending on the chosen version so 3 or 4 electrical wires have to be connected There is a water input and output as well as an air inlet on each lateral side and one air outlet on the front The front panel can receive various accessories depending on the version Six fronts with different air outlets B 3D 4D F G S Various versions are available 2 or 3 speeds rated voltage 12V or 24V ...

Page 3: ... 7442 0160 7444 0160 7452 0160 7706 0160 7606 0160 7202 24 V Ø 14 0160 7001 0160 7431 0160 7441 0160 7447 0160 7451 0160 7705 0160 7605 0160 7201 Ø 16 0160 7003 0160 7433 0160 7443 0160 7445 0160 7453 0160 7707 0160 7607 0160 7203 Front panel versions Voltage Ø pipes mm 3D40 3D45 3D50 3D55 3D60 3D65 3D70 Reference Reference Reference Reference Reference Reference Reference 12 V Ø 14 0160 7340 0160...

Page 4: ...n t drill the heater carcass in order not to damage the internal components Connect water input and output using cooling hoses with corresponding diameter cf product part number 1 Use suitable clamps Respect the preferential direction of circulation of water It s recommended to use water hose adapted to the application see Siroco references Ø internal of the water hose Part number Ø 12 0410 0212 Ø...

Page 5: ...e suitable clamps to insure the airproofness of the system Test the airproofness of the circuit to prevent air leaks Option Possibility to connect a Ø70mm air sleeve on one air inlet air recycling or fresh air Make sure to use the suitable clamps to insure the airproofness of the system Test the airproofness of the circuit to prevent air leaks Option Possibility to connect an air inlet grid for be...

Page 6: ...O S A S 10 rue Jean Rostand Z I BP 315 69745 GENAS Cedex Tel 33 0 4 78 90 96 96 Fax 33 0 4 78 90 15 98 www siroco fr Page 6 sur 8 Plug the connector respecting the circuit diagram Use electric wires with at least 1 5 mm cross section 2 speeds 3 speeds 4 ...

Page 7: ...istributor Ventilation s low and middle speeds don t work The resistance group is defective Contact your distributor The device can t be stopped Internal short circuit in the device Unplug the device first of all switch off battery power supply and contact your distributor The heater works only at reduced power The voltage isn t suitable The voltage of the device and of the vehicle must be the sam...

Page 8: ...ictly respected according to the country of use For safety reasons fire hazard the power supply of the product has to be protected by a specifically dedicated fuse The fuse characteristic is given only as an indication please verify the specific fuse required for each application Switch off electric power supply before working on the product Be careful while servicing the device or its connections...