background image

  

10

Figure 5A.

6.7 

Use the small heat shield contained in
the fixing kit bag to cover the batteries.
Fold  this  element  by  hand  and  place
as show on figure 5B.

6.8   CHECK FOR GAS SOUNDNESS

Turn on the gas supply and check for gas
soundness  with  a  suitable  leak  detection
fluid (see BS 6891).

Please  check  all  joints  including  the  pilot
assembly.

6.9

FUEL BED ASSEMBLY

Please  refer  to  the  User’s  section  for
details  on  assembling  the  fuel  effect
components (Page 5, 6).

7

FUNCTIONAL CHECKS

Remove  the  pressure  test  point  sealing
screw  from  the  isolation  elbow  and  attach
a suitable pressure gauge.

Light  the  pilot  and  check  the  correct
operation  of  the  burner  at  all  the  flame
settings.  Refer  to  the  Operating
instructions on pages 4 and 5.

Check  that  the  inlet  gas  pressure  is  as
stated  on  page  8  when  the  fire  is  at  its
highest setting.

Once  the  fire  has  been  lit  for  5  minutes
turn  the  gas  OFF  at  the  isolating  elbow.
After  a  further  3  minutes  turn  the  gas
supply  ON  again,  if  the  gas  has  stopped
flowing,  the  Flame  Supervision  Device
(FSD) is operating correctly. Always check
that  the  gas  has  stopped  flowing  even  if
you hear the FSD valve close within the 3-
minute period.

Turn  OFF  the  appliance  and  the  gas
supply  and  refit  the  pressure  test  point
sealing screw.
Turn  ON  the  gas  supply  and  check  for
leaks  around  the  pressure  test  point
sealing  screw  with  a  suitable  leak
detection fluid.

8

CHECK FOR SPILLAGE

A  SPILLAGE  CHECK  MUST  BE
MADE  BEFORE  THE  INSTALLED
APPLIANCE  IS  LEFT  WITH  THE
CUSTOMER.  DO  THIS  TEST  WITH
ALL  THE  COALS  FITTED  AND  THE
FENDER  AND  ASHPAN  IN  PLACE.
CARRY  OUT  THE  TEST  AS
FOLLOWS:

8.1

Close  all  doors  and  windows  in  the  room
containing the appliance.

8.2

Light  the  appliance  and  set  to  the  HIGH
setting.

8.3

Leave  the  appliance  ON  for  5  minutes  then
light  a  smoke  match.  The  match  should  be
inserted 10mm below the top of the opening
and  be  pointed  upwards  at  45°  to  the
horizontal.

    Move  the  smoke  match  across  the  opening.

The  installation  is  satisfactory  if  all  the
smoke is drawn into the chimney.

DOWN  90.00°  R 1.00 

DOWN  90.00°  R 1.00 

DOWN  90.00°  R 1.00 

A

Figure 5B

A

RECIVER

V.11.07

Summary of Contents for Mystique ECO 4

Page 1: ...N GB AND IE ONLY AT A SUPPLY PRESSURE OF 20mbar USER S INSTALLATION AND SERVICE MANUAL PLEASE KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE Our policy is one of constant development and improvement Strict accuracy of illustrations and specifications is not guaranteed Modifications to design and materials may be necessary subsequent to publication V 11 07 ...

Page 2: ..._______________ 2 GENERAL INSTALLATION REQUIREMENTS ___________________7 3 CHECK CARTON CONTENTS _______________________________ 4 THE FIREPLACE _____________________________________ 5 GAS SUPPLY PIPE ____________________________________ 6 APPLIANCE INSTALLATION _______________________________ 6 8 CHECK FOR GAS SOUNDNESS____________________________ 10 6 9 FUEL BED ASSEMBLY ________________________...

Page 3: ... FOR ANY PROJECTION e g SHELF etc 150mm DEEP MADE FROM WOOD OR ANY OTHER COMBUSTIBLE MATERIAL IS 766mm FOR COMBUSTIBLE PROJECTIONS ABOVE 150mm DEPTH ADD 12 5mm TO THE ABOVE CLEARANCE FOR EVERY 25mm OF ADDITIONAL PROJECTION DEPTH 9 NEVER THROW PAPER OR OTHER MATERIAL ONTO THE FIRE 10 IT SHOULD BE APPRECIATED THAT ALTHOUGH THIS APPLIANCE CONFORMS TO ALL THE REQUIRED STANDARDS IT IS A DECORATIVE FUEL...

Page 4: ... a few seconds you will hear the clicking spark to the pilot light Once the pilot is lit the fire main burner will come on to the high position this whole process will take no more than 20 seconds TO SELECT THE REQUIRED FLAME LEVEL To turn down the fire point the handset to the sensor on your fire then push and hold the minus button small flame if you release immediately the flame will go to low i...

Page 5: ...o 4 and the serial number Both of which can be found on the data badge which is located next to the control knob behind the ash pan cover A full service kit is available FUEL BED ASSEMBLY Using the two brackets supplied in the fixing kit included are two _ screws fold these brackets by hand with the black painted facing forward locate them into the two slots in the burner bracket and fix them in p...

Page 6: ...f rear ceramic front ceramic and 9 pebbles Place 5 coals pebbles on the front matrix and 4 on the back row REAR MATRIX FRONT MATRIX FLAME PATH Figure 1 The Coals Pebbles MUST be placed sitting on top of the front ceramic resting between the pillars of the floor matrix as shown in fig 1 and photos This allows the flame path to take its correct direction V 11 07 ...

Page 7: ...son and installed in accordance with the current edition of I S 813 Domestic Gas Installations and the current building regulations 2 2 The appliance can be used in a builders opening or fireplace conforming to the sizes below The Minimum depth of the opening see Figure 2 dimension C in the case of the Hotbox shall be 215mm and 235mm for the Convector box The minimum front width see Figure 2 dimen...

Page 8: ...e fitted in the same room as the appliance or in any area from which ventilation is taken IF IT IS LIKLEY TO AFFECT THE SAFE OPERATION OF THE APPLIANCE If there is a fan in such a locality note the spillage test requirements detailed on page 16 2 14 VENTILATION REQUIREMENTS For use in GB purpose built ventilation is not normally required for this appliance For use in I E ventilation must be in acc...

Page 9: ...e the box in place using the screws provided If the alternative cable fixing kit is to be used please read the installation instructions enclosed with the kit in conjunction with these instructions 6 3 Once the box has been securely fixed the gas supply can be connected to the isolation elbow Gas connection is by concealed connection only Remember to protect the end of the supply pipe when passing...

Page 10: ...gas supply ON again if the gas has stopped flowing the Flame Supervision Device FSD is operating correctly Always check that the gas has stopped flowing even if you hear the FSD valve close within the 3 minute period Turn OFF the appliance and the gas supply and refit the pressure test point sealing screw Turn ON the gas supply and check for leaks around the pressure test point sealing screw with ...

Page 11: ...e Oxygen level in the room falls below safe levels usually due to interruption of the evacuation of combustion products i e a blocked chimney etc b Describe the restart procedures c Point out that on repeated operation of the ODS system seek expert advice 9 5 Hand over these instructions to the customer for keeping in a safe place 9 6 Recommend that the appliance and chimney should be inspected an...

Page 12: ...park electrode lead e Remove the two screws fixing the assy 10 3 TO REMOVE THE GAS VALVE a Follow 10 1 above to remove the burner tray b Disconnect the lead from the control unit c Disconnect the thermocouple nut from the rear of the valve d Disconnect the pilot tube from the valve e Remove the injector tube f Remove the two screws securing the valve g Assemble in the reverse order V 11 07 ...

Page 13: ... lit or fire goes out in use See Flame Failure Functional Check Uneven flame pattern e g flame at one side only 1 The fuel effect may need adjusting to even the flame pattern See page 6 Blue flames 1 The fire will burn blue on initial lighting until sufficient heat is generated causing the flames to burn yellow Typically 10 minutes 2 Insufficient gas pressure Check the supply pressure to the appli...

Page 14: ...T Ensure there is no debris around the spark ignitor e g coal soot etc which could short the spark clean the area IGNITION FUNCTIONAL CHECK 2 NO Consult the User s section in this manual and retry YES Check for damaged or defective control knob spindle or cam operation Check for correct location of peizo components Correct and retry NO Is the valve being operated correctly NO Reset the electrode g...

Page 15: ... data badge NO Problem is with the pipework or fittings which lead to the fire YES Run for 3 mins turn off time interval until mag unit shuts with a click Is this greater than 7 seconds YES With the fire running on Full is the gas pressure as stated on the data badge Will the burner stay alight Light the burner and keep the control knob pushed in for 10 20 seconds before letting go Ensure there is...

Reviews: