10
Figure 5A.
6.7
Use the small heat shield contained in
the fixing kit bag to cover the batteries.
Fold this element by hand and place
as show on figure 5B.
6.8 CHECK FOR GAS SOUNDNESS
Turn on the gas supply and check for gas
soundness with a suitable leak detection
fluid (see BS 6891).
Please check all joints including the pilot
assembly.
6.9
FUEL BED ASSEMBLY
Please refer to the User’s section for
details on assembling the fuel effect
components (Page 5, 6).
7
FUNCTIONAL CHECKS
Remove the pressure test point sealing
screw from the isolation elbow and attach
a suitable pressure gauge.
Light the pilot and check the correct
operation of the burner at all the flame
settings. Refer to the Operating
instructions on pages 4 and 5.
Check that the inlet gas pressure is as
stated on page 8 when the fire is at its
highest setting.
Once the fire has been lit for 5 minutes
turn the gas OFF at the isolating elbow.
After a further 3 minutes turn the gas
supply ON again, if the gas has stopped
flowing, the Flame Supervision Device
(FSD) is operating correctly. Always check
that the gas has stopped flowing even if
you hear the FSD valve close within the 3-
minute period.
Turn OFF the appliance and the gas
supply and refit the pressure test point
sealing screw.
Turn ON the gas supply and check for
leaks around the pressure test point
sealing screw with a suitable leak
detection fluid.
8
CHECK FOR SPILLAGE
A SPILLAGE CHECK MUST BE
MADE BEFORE THE INSTALLED
APPLIANCE IS LEFT WITH THE
CUSTOMER. DO THIS TEST WITH
ALL THE COALS FITTED AND THE
FENDER AND ASHPAN IN PLACE.
CARRY OUT THE TEST AS
FOLLOWS:
8.1
Close all doors and windows in the room
containing the appliance.
8.2
Light the appliance and set to the HIGH
setting.
8.3
Leave the appliance ON for 5 minutes then
light a smoke match. The match should be
inserted 10mm below the top of the opening
and be pointed upwards at 45° to the
horizontal.
Move the smoke match across the opening.
The installation is satisfactory if all the
smoke is drawn into the chimney.
DOWN 90.00° R 1.00
DOWN 90.00° R 1.00
DOWN 90.00° R 1.00
A
Figure 5B
A
RECIVER
V.11.07