background image

D U C T I N G

(Not applicable if the range hood is 

used in re-circulating mode)

WARNING:  Do not vent this        

appliance into any other ductwork, 

spaces between walls, ceilings,   

attics, garages or any other confined 

space. 

B E F O R E   Y O U   B E G I N

The  manufacturer  declines  all      
responsibility  in  the  event  of  failure 
to  observe  the  instructions  given 
here  for  installation,  maintenance 
and  suitable  operation  of  the            
product.    The  manufacturer  further 
declines  all  responsibility  for  injury 
due  to  negligence  and  the  warranty 
of the unit automatically expires due 
to  improper  maintenance  and/or   
installation.

BEFORE YOU BEGIN:

It is advisable to test run the 

range hood before installation.

Please  read  this  entire  manual  and 
ensure that you are fully  conversant 
with the requirements and limitations

direct  route  possible.  Always,    
wherever  reduce  the  number  of  
transitions  and  turns  with  as  few 
sharp angles as possible.

1

Figure 1

Two staggered 45 degree angles are  
better  than  one  90  degree.    Make 
these  turns  as  far  away  from  the 
motor  exhaust  as  possible,  with  as 
much space between each bend.

External Venting Requirements

When planning  new  ductwork,  always 
look  for  the  most  direct  route  to  the 
outside. Venting  can be  done  through 
the  roof  or  directly  through  the  back 
outside wall. (See Figure 1 )  

Only  use  rigid  type  metal  ducting 
(plastic ducting is generally not permit-
ted  by  code).    Flexible  ducting  could 
restrict  airflow  by  up  to  50%.    Always 
fasten  connections  with  sheet  metal 
screws and tape all joints with certified 
Silver Tape or Duct Tape. 

Do  not  use 

screws  to  fasten              ductwork  to 
the  hood

, only use tape as the screws 

will  stop  the  dampers  from  opening 
and  your  hood  will  not  work.    This 
hood  requires  a  6”  round  duct  outlet.  
You can  increase  the  duct size  of  the 
duct  run  but  never  decrease  it.  Use 
the shortest and most 

Summary of Contents for SUF1

Page 1: ...red by these instructions SUF1 B E F O R E I N S T A L L A T I O N ENSURE THERE IS NO VISIBLE OR HIDDEN DAMAGE SUSTAINED DURING SHIPPING S H I P P I N G D A M A G E MUST BE REPORTED WITHIN 5 DAYS OF R...

Page 2: ...ore commencing installation All electrical wiring must be properly installed insulated and grounded and conform to all applicable codes and standards Make sure all existing duct work is clean of greas...

Page 3: ...uct Run Calculation 2 ELECTRICAL 2 Electrical Supply 2 INSTALLATION 3 Connecting Electricity and Ducting 3 Re Circulating Requirements 4 OPERATING PROCEDURES 5 General Advice 5 Functions 5 MAINTENANCE...

Page 4: ...sible Always wherever reduce the number of transitions and turns with as few sharp angles as possible 1 Figure 1 Two staggered 45 degree angles are better than one 90 degree Make these turns as far aw...

Page 5: ...wall on which the hood is to be mounted Range hoods may interrupt the proper flow of combustion gases from fireplaces gas furnaces and gas water heaters To minimize the risk of drawing these lethal g...

Page 6: ...f the hood 4 5 To install the appliance adjust the position of the stop side springs using the appropriate screws according to the thickness of the board The base of the cabinet must be from 0 4 to 1...

Page 7: ...ase filter Ensure that the plastic tabs on the carbon filter are facing outwards otherwise it will be difficult to remove it later for replacement A short length of ductwork must be connected from the...

Page 8: ...sized pot covering the entire burner to reduce the risk of boiling over and burning In the event of a range top grease fire observe the following Switch OFF the range hood Turn off the cook top then...

Page 9: ...nless steel cleaner for exterior surfaces Follow the manufacturers directions Generally the foam is sprayed onto a clean dry cloth and then applied to the stainless steel Allow the foam to react on th...

Page 10: ...for a period of three years from the original date of purchase There are no other warranties express or implied including but not limited to implied warranties of merchantability or fitness for a par...

Page 11: ...8 Staple Invoice Here...

Page 12: ...RANGE HOODS LTD 1051 Clinton Street 1252 Speers Road Unit 11 Buffalo NY 14206 Oakville ON L6L 5N9 Telephone Toll Free 866 528 4987 Telephone 905 257 0046 Fax Toll Free 866 365 9204 Fax 905 847 0330 ww...

Reviews: