background image

1

S-DD2-L EMIC

INTEGRATED DOWNDRAFT INSTALLATION 

INSTRUCTIONS FOR

SEM 7 & SEM 8 motors

Congratulations on your purchase!

Thank you for choosing a Sirius product.

SDD2 L EMIC 880 

 

 

EAN #9351116002749

SDD2 L EMIC 1180 

 

 

EAN #9351116004712

   

Summary of Contents for 9351116002749

Page 1: ...C INTEGRATED DOWNDRAFT INSTALLATION INSTRUCTIONS FOR SEM 7 SEM 8 motors Congratulations on your purchase Thank you for choosing a Sirius product SDD2 L EMIC 880 EAN 9351116002749 SDD2 L EMIC 1180 EAN...

Page 2: ...2 S DD2 L EMIC INTEGRATED DOWNDRAFT RANGEHOOD INSTALLATION GUIDE...

Page 3: ...e contact your local city office your household waste disposal service or the shop where you purchased the product This appliance is marked according to the European directive 2002 96 EC on waste elec...

Page 4: ...sue then charges will apply for service and parts Flexible ducting is not permitted under any circumstances Flexible ducting has been found to increase noise levels increase vibration and reduce airfl...

Page 5: ...lamb or operate gas hobs without pots or pans on them under the hood itself the flames sucked into the hood might damage the appliance Frying under the appliance must be done under constant supervisio...

Page 6: ...6 APPLIANCE DIAGRAMS S DD2 L EMIC INTEGRATED DOWNDRAFT RANGEHOOD INSTALLATION GUIDE...

Page 7: ...t be ducted into roof space The use of discontinued ducts is not allowed without the approval of a qualified technician Check PARTS LIST on page 25 for all included parts prior to discarding packaging...

Page 8: ...elbows in the ducting since each elbow reduces the air capacity of 1 linear meter Ex if you use no 2 x 90 elbows the length of piping should not exceed 5 meters Avoid abrupt direction changes Optimum...

Page 9: ...essional It is vital that the cutout is perfectly made so as not to have fitment issues with the product The cutout section can be used thickness dependent Min 10mm 32mm Max as the top of the downdraf...

Page 10: ...ions need to be in correspondence with the internal cabinetry Fig 5 Note Min 860mm Max 1000mm for 880 units and Min 1160mm Max 1300mm for 1180 units Secure the two sections A and B C and D together us...

Page 11: ...e in place as per Fig 7 Fig 8 Fig 9 Note The screws put in place in Fig 6 cannot sit inside the width of the benchtop cutout as they will obstruct the downdraft body when lowered into place Warning th...

Page 12: ...ustable Brackets Fig 10 These brackets are fixed in between the horizontal length brackets and are put into position as per Fig 11 Insert one at either end ensuring that the slotted holes and the roun...

Page 13: ...t is in its set position Fig 14a If using the bottom outlet to vent the range hood out it is advised to fit Part B SPS 51070102735 to the unit at this stage as fitting it after the unit is lowered may...

Page 14: ...with the benchtop Using a Phillips head screwdriver adjust the threaded screws up or down to according to the desired thickness of the insert Fig 15 To determine the correct line up of the downdraft...

Page 15: ...see fig 18A for central installation fig 18B for lateral installation Before fixing the push button panel ensure that the controls do not prevent any doors from closing Once the unit is fixed in posi...

Page 16: ...ate Part D Fig 4 2 Connect air outlet collar Part B to the same fixing points as removed from side or bottom cover plate Part C and tighten Depending on sub floor clearances this step may be required...

Page 17: ...o round adapter Part A then connect length of ducting Part K 2 to the 200mm outlet 2B Secure to the motor with a universal ring clamp Part G See page 12 for ducting to vent N A for SEM 7 motor STEP 4A...

Page 18: ...Part D and replace with front cover plate Part E If venting from front check to see if front adaptor plate Part D is attached STEP 1B Remove replace with cover plate Part C Remove replace with cover p...

Page 19: ...directly onto the collar on the front adaptor plate Part D 3 Fix in place using a universal ring clamp Part G PART G PART G PART K 2 PART K 2 PART K 2 SEM 7 OUTSIDE INSIDE WALL Ducting to SEM 8 motor...

Page 20: ...metres away from the downdraft Failure to do so may result in additional noise level of the downdraft Maximum distance is 7 metres however 3 5 metres is optimum to minimise noise and maximise performa...

Page 21: ...roved power socket 10AMP power socket which must remain accessible after installation in compliance with installation regulations We decline any responsibility in case of accidents caused by a lack of...

Page 22: ...calibration will be reset After the next 3 cycles the downdraft will carry out its self calibration Stand by When the extractable unit is closed and the light is switched off the control panel after...

Page 23: ...ercially available household detergents diluted in water Then rinse with clean water and dry with a soft cloth Filter cleaning After 30 hours of operation the downdraft will signal the grease filter s...

Page 24: ...uld bend the contacts The rangehood has low performance Check that The motor speed selected is sufficient for the quantity of fumes and vapors present in the room The kitchen is ventilated well enough...

Page 25: ...t of the rangehood Disconnect the cable Twist the light globe and pull to remove 2 Remove the two screw under the top panel and the three on the back five screws in total 4 Remove the screws holding t...

Page 26: ...cian authorized for that brand if out of warranty Contact www siriusbrand com 1300 762 219 NOTE When calling please mention the appliance details Production date Fig 9A Type Fig 9B and equipment Fig 9...

Page 27: ...51070102735 C BOTTOM SIDE EXIT PLATE SPS 20059000094 D FRONT REAR VENT ADAPTOR SPS 20059120071 E FRONT REAR VENT COVER PLATE SPS 75059000082 F UPRIGHT FIXING BRACKETS SPS 77002002999 G UNIVERSAL RING...

Page 28: ...om side cover collar SPS 51070102735 PART C Bottom side exit connector SPS 20059000094 PART D Front rear vent adaptor SPS 20059120071 PART F PART E Upright fixing brackets SPS 77002002999 Front rear v...

Page 29: ...GUIDE 29 PART G Universal ring clamp URC25 215 325 PARTS LIST OPTIONAL PIECES To be purchased separately PART H 150mm to 200mm Duct expander GDR 150 200 PART J 200mm diameter connector piece GDC 200...

Page 30: ...30 S DD2 L EMIC INTEGRATED DOWNDRAFT RANGEHOOD INSTALLATION GUIDE WIRING DIAGRAMS...

Page 31: ...r ownership NOW you qualify for Sirius s Total Peace of Mind Protection Plan Australian New Zealand 3 6 Year Protection Plan This guarantees your appliance for a full 3 years parts and labour 10 years...

Page 32: ...is warranty will not apply where a The fault is caused by accident misuse an infestation of insect and or vermin fire flood or the use of products not approved by Arisit Pty Limited b There has been a...

Reviews: