background image

Registered in England No. 08405712
VAT Registration No. GB163 04 0349 

Siretta Ltd

Basingstoke Road

Spencers Wood

Reading

Berkshire RG7 1PW

sales
fax
email
web

+44(0)118 976 9000
+44(0)118 976 9020

[email protected]

www.siretta.com

4

SNYPER-LTE Family

User Manual

Overview

SNYPER-LTE 

1.  SNYPER-LTE signal and network analyser

2.  Multi region power supply

3.  Blue antenna - General purpose LTE(4G), UMTS(3G) & GPRS(2G) 

coverage

4.  Silver antenna - For LTE 2600MHz only

5.  USB cable

6.  In car charger

7.  Hard carrying case

Quick start guide

1

2

3

4

5

6

7

8

Figure 1

. SNYPER-LTE case contents

1

2

3

4

5

6

7

8

What’s in the Box?

Summary of Contents for SNYPER-LTE

Page 1: ...SNYPER LTE Family 1 SNYPER LTE 4G 3G 2G Cellular Signal Network Analyser 2 SNYPER LTE Spectrum 4G 3G 2G Cellular Signal Network Analyser with liveSCAN Antenna Kit User Manual Rev 1 2...

Page 2: ...erating Frequencies Detail 9 Product Images 10 First Time Use of the SNYPER LTE Family 12 Charging and Battery Status 13 Main Menu 14 Saved Results Menu 15 Viewing Saved LTE Survey Results 16 Viewing...

Page 3: ...9020 sales siretta com www siretta com 3 SNYPER LTE Family User Manual This document explains the operation of and technical characteristics of the SNYPER LTE family The SNYPER LTE Family is an evolvi...

Page 4: ...iretta com www siretta com 4 SNYPER LTE Family User Manual Overview SNYPER LTE 1 SNYPER LTE signal and network analyser 2 Multi region power supply 3 Blue antenna General purpose LTE 4G UMTS 3G GPRS 2...

Page 5: ...dge cellular equipment can be installed with confidence that the right antenna selection and placement has been made and the right network provider for the application chosen The SNYPER LTE has the fo...

Page 6: ...LTE Family User Manual 1 SNYPER LTE Spectrum signal and network analyser 2 Multi region power supply 3 Blue antenna General purpose LTE 4G UMTS 3G GPRS 2G coverage 4 Silver antenna For LTE 2600MHz onl...

Page 7: ...enna has been specifically designed to complement the SNYPER LTE Spectrum when performing live scans By use of this directional antenna the bearing of a base station may be estimated On top of the SNY...

Page 8: ...d bands 800 1800 2600MHz Dimensions 141 x 76 x 36mm Weight Approx 210g including antenna Antenna length 89 2mm Operating temperature range 20 to 55 C Storage temperature range 30 to 75 C Operating hum...

Page 9: ...45MHz DCS1800 1710 2 1784 8 1805 2 1879 8 512 885 95MHz WCDMA2100 B1 1922 4 1977 6 2112 4 2167 6 Tx 9612 9888 Rx 10562 10828 190MHz WCDMA850 B5 826 4 846 6 871 4 891 6 Tx 4132 4233 Rx 4357 4458 45MHz...

Page 10: ...ales fax email web 44 0 118 976 9000 44 0 118 976 9020 sales siretta com www siretta com 10 SNYPER LTE Family User Manual Product Images Figure 3 Front view of the SNYPER LTE Product 320 x 240 LCD Dis...

Page 11: ...ing Berkshire RG7 1PW sales fax email web 44 0 118 976 9000 44 0 118 976 9020 sales siretta com www siretta com 11 SNYPER LTE Family User Manual Figure 4 Bottom view of the SNYPER LTE Product Figure 5...

Page 12: ...such as a computer using the supplied cable Ensure the antenna is screwed firmly into place on the device and isn t loose Insert a 4G SIM card into the SIM card slot as shown below in figure 6 The SIM...

Page 13: ...will be required Approximately 4 6 hours are needed to fully charge your SNYPER The device will be charged when it is plugged into a USB power source the supplied AC adaptor the supplied car charge a...

Page 14: ...ed using the UP DOWN buttons Once the chosen menu is highlighted click OK Press the BACK button to return to the main menu Figure 10 Main Menu screen Saved Results Reviews previously saved survey Surv...

Page 15: ...9020 sales siretta com www siretta com 15 SNYPER LTE Family User Manual Saved Results The Saved Surveys menu allows you to review saved survey results on your SNYPER product SNYPER LTE model can stor...

Page 16: ...2 Select the survey you wish to view using the UP DOWN and OK buttons NOTE Steps 1 2 are only valid for SNYPER LTE Spectrum see Show Results over page for SNYPER LTE Deleting a Saved Survey To delete...

Page 17: ...to weakest To switch between all signals found in the survey use the LEFT RIGHT buttons Figure 14 Displaying survey results NOTE Two listings may be shown for one network operator This listing is crea...

Page 18: ...User Manual Viewing Saved GSM UMTS Survey Results Step 3 Once you have selected the saved survey you wish to view the Survey Menu will be displayed as shown in figure 17 below Figure 17 Survey Menu sc...

Page 19: ...ls from strongest to weakest To switch between all signals found in the survey use the LEFT RIGHT buttons Figure 18 Displaying survey results NOTE Two listings may be shown for one network operator Th...

Page 20: ...Single Survey A single complete survey of the cellular environment as seen by the SNYPER The survey result is available as a csv file with a htm summary file liveSCAN Only available with SNYPER LTE Sp...

Page 21: ...y to perform Performing a Single Survey To perform a single survey on your SNYPER follow the steps below Step 1 Select Survey from the main menu and press OK Step 2 Use the UP DOWN buttons to select w...

Page 22: ...ells from strongest to weakest To switch between all signals found in the survey use the LEFT RIGHT buttons Figure 22 Displaying survey results NOTE Two listings may be shown for one network operator...

Page 23: ...of that cell will be reported liveSCAN can be used in two modes Directional liveSCAN When conducting liveSCAN with a directional antenna moving the antenna horizontally will show the direction with th...

Page 24: ...n your SNYPER LTE Spectrum follow the steps below Step 1 Conduct a survey of any type using an omnidirectional antenna Step 2 When the survey is complete view the results acquired Use the LEFT RIGHT b...

Page 25: ...position The green line shows the actual and historical liveSCAN measurement data Use the UP DOWN buttons to switch between display modes Average reading Number of readings Elapsed time Network opera...

Page 26: ...gs ENG English DEU German FRE French DAN Danish NOR Norwegian ITA Italian Default ENG Brightness SNYPER LCD brightness The screen brightness has 6 settings 0 lowest 5 highest Auto Off Automatic power...

Page 27: ...et will delete all saved files from the SNYPER Save Settings Saves setup menu changes Saves any changes made to the setup menu NOTE The SNYPER doesn t automatically save new settings ADV The ADV optio...

Page 28: ...e signal strength RSSI Received Signal Strength Indicator Values range from 0 31 the higher the number the higher the signal strength Signal Percentage signal received Values range from 0 100 the high...

Page 29: ...About screen By selecting About from the main menu information about your SNYPER product will be displayed as shown below in figure 28 About Menu HW SNYPER LTE Family model hardware version BV Batter...

Page 30: ...rom the main menu and use the RIGHT button to enable PC Connect Windows Explorer will open automatically If Windows explorer does not open automatically open it by pressing and holding the Windows key...

Page 31: ...email web 44 0 118 976 9000 44 0 118 976 9020 sales siretta com www siretta com 31 SNYPER LTE Family User Manual Selecting GSM UMTS Results If you wish to view the GSM UMTS results stored on your SNY...

Page 32: ...les fax email web 44 0 118 976 9000 44 0 118 976 9020 sales siretta com www siretta com 32 SNYPER LTE Family User Manual Selecting LTE Results If you wish to view the LTE results stored on your SNYPER...

Page 33: ...ter use remember to power off your SNYPER The device can be powered off in the following 2 ways Selecting the Power Off option from the main menu The device will display a power off message as shown b...

Page 34: ...ilable as a complimentary service on the Siretta website Updated software may contain improvements and or new features WARNING The software update procedure does require the SNYPER to be factory reset...

Page 35: ...ain menu and use the RIGHT button to enable PC Connect Windows Explorer will open automatically If Windows explorer does not open automatically open it by pressing and holding the Windows key and e Fi...

Page 36: ...re update Figure 41 Confirm software update Once you have confirmed the software update the process will begin automatically Once the software update is complete the SNYPER will turn off for approxima...

Page 37: ...neral Precautions Do not exceed the environmental and electrical limits as specified Avoid exposing your SNYPER product to lit cigarettes naked flames or to extreme hot or cold temperatures Never try...

Page 38: ...required The use of this product may be dangerous and has to be used with caution in the following areas Where it can interfere with other electronic devices in environments such as hospitals airport...

Page 39: ...formation Copyright Declaration 2018 Siretta Ltd All rights reserved No part of this publication may be reproduced transmitted transcribed stored in a retrieval system or translated into any language...

Page 40: ...r any injury loss or damage of any kind incurred using this information Siretta Ltd does not take responsibility for any cellular product or system installed because of a survey conducted by the SNYPE...

Page 41: ...Measured signal strength of the network in dBm DL Downlink EARFCN E UTRA Absolute Radio Frequency Channel Number GPRS General Packet Radio Service GSM Global System for Mobile Communications IMEI Int...

Page 42: ...ke Road Spencers Wood Reading Berkshire RG7 1PW United Kingdom sales fax email Company No 08405712 VAT Registration No GB163 04 0349 44 0 118 976 9000 44 0 118 976 9020 sales siretta com www siretta c...

Reviews: