PTZ Linking
Select a preset, a patrol or a pattern to be executed by the camera when the alarm input
occurs. When you select an option, the other options become unavailable. If necessary, go to
the Live View page first, to create the preset, patrol or pattern.
12.4
Alarm Output
Events > Alarm Output
What this tab is for
The camera has alarm output functionality for alarm application. On the Alarm Output tab,
you can configure the related settings and activate/deactivate a manual alarm.
To configure the Alarm Output settings
1
In the Alarm Output No. list, select the alarm output channel.
2
(Optional) In Alarm Name, type a name for the output.
3
In the Delay list, select a delay time.
The delay time indicates the time span during which the alarm output remains active
after the alarm occurs.
4
On the Arming Schedule tab, drag your mouse pointer across the required day(s) to set
the arming schedule.
A Copy button appears as you move your pointer across the schedule. You can click it to
copy the settings of a specific day to another day.
You can click a time section to edit, save or delete it.
5
(Optional) You can copy your settings to other alarm outputs.
6
Click Save.
To activate a manual alarm
● Click Manual Alarm.
The Alarm Status changes to ON.