Siqura HSD62x PRH Network Cameras 

Outdoor IP PTZ dome with Day/Night, WDR, Pressurized Housing 

Quick Start Guide 

 

RJ-45 connector LEDs

 Green indicates a good 

network connection; yellow verifies network 
activity. 

To mount the HSD62X with the mini wall mount 
1.

 

Make a hole in the wall or metal access plate for the cables and secure the supplied cable gland in 
the wall. 

2.

 

Ensure that the weather resistant gasket is correctly attached to the mount.  

3.

 

Thread the cables through the wall mount and screw it onto the wall. 

4.

 

Attach the waterproof boot to the mini wall mount. 

5.

 

Thread the cables through the outdoor tube adaptor and fix it to the mini wall mount with the 
supplied screws and washers. 

6.

 

Clip the safety wire to the dome camera.  

7.

 

To keep insects out, block the cable entry hole with the supplied sponge. 

8.

 

Connect the cables to the dome camera. 

9.

 

Attach the dome to the outdoor tube adaptor and fasten them together with the supplied screws. 

Step 1: Product Inventory 

Figure 1  HD62xWDR package contents 

Before proceeding, ensure that the HSD62x PRH package contains the items 
listed below. 

Please note that the wall mounts must be ordered separately. 

HSD62x camera 

(622 and 626 

include outdoor 

tube adaptor) 

30 cm cable harness  

Optical cover 

Waterproof boot 

Security 

TORX 

M3 screws 

Lubricant 

Quick Start  

Guide 

Step 2: Cabling 

 

For operation, the HSD62x/SFP camera requires the following: 

 

CAT-5 Ethernet cable with an RJ-45 connector 

or

 

 

An SFP module as described in the XSNet™ SFP data sheet and fiber optic 

cable and connectors compatible with the chosen SFP module. 

 

A cable harness for power, analog video, and audio transmissions, equipped 

with a 22-pin connector for connecting to the HSD62x (table 1). 

Figure 2  Cable harness components 

Figure 4  22-pin  

connector pins  

 

24 VAC 

Ground (GND) 

24 VAC 

 

Step 3: 22-Pin Connector Definition 

Table 1  22-pin connector assignments 

Pin 

Definition 

Cable 

Color 

Rating 

AC 24-1/DC(+) 

20/18 AWG 

Red 

 

Alarm out NC 

 

White 

Photo Relay output 300V 

AC 24-2/DC(-) 

20/18 AWG 

Black 

 

Alarm out, NO 

 

White/black 

Photo Relay output 300V 

FG 

20/18 AWG 

Yellow 

 

Alarm out COM 

24 AWG 

Green/black 

Photo Relay output 300V 

Audio in 

Yellow/black 

 

Audio out 

Orange/black 

 

Audio GND 

Green/black 

 

10 

Audio GND 

Brown/black 

 

11 

ISOG 

 

Blue/white 

 

12 

Alarm 1 

 

Red/white 

Input 5V 10KO pull up 
Photo Relay output 300V 

13 

Alarm 2 

 

Purple 

14 

Alarm 3 

 

Gray 

15 

Alarm 4 

 

Blue 

16 

Alarm 5 

 

White/black 

17 

Alarm 6 

 

Orange/black 

18 

Alarm 7 

 

Purple/white 

19 

Alarm 8 

 

Gray/black 

20 

Alarm GND 

 

Brown/white 

Input 5V 10KO pull up 

21 

Video GND 

20 AWG 

Black/gray 

 

22 

Video 

Red/gray 

 

 

Step 5a: Installing with a Mini Wall Mount 

Installation requires the following tools: 

 

Dome camera 

 

 

Supplied waterproof boot

 

 

Mini wall mount

 

 

Screws and screw anchors

 

 

Screwdriver and drill

 

Figure 9  Mini wall mount 

Figure 5  RJ-45 

connector LEDs 

24 VAC 

Ground (GND) 

24 VAC 

Figure 3  Power input details 

Step 4: Wall Mount Installation 

To prepare the HSD62x for installation 
1.

 

Remove the outdoor tube adaptor by rotating counter clockwise (figure 8a). 

2.

 

Rotate to remove the protective cover. 

3.

 

Make a note of the IP address on the label attached to the cylindrical heat sink.  

4.

 

Remove the PE cloth and take off the lens cap. 

5.

 

Generously apply the supplied lubricant to the optical cover’s waterproof boot to 
ensure an IP66 quality installation (figure 8b). 

6.

 

Loosen the screw head alignment pins on the dome cover by turning 

clockwise

 

and line up the alignment pin and screws on the optical cover with the holes in 
the dome body. 

7.

 

Attach the optical cover to the dome body by pressing gently down on the sides 
of the dome cover (figure 9c). 

8.

 

Turn the screw head alignment pins 

counter-clockwise

 with a suitable screwdriver 

to lock the dome into place and secure the dome with the included Phillips-head 
or TORX screw. 

Figure 6  Siqura WM01A 

Mini Wall Bracket 

Figure 7  Siqura WM03A 

Gooseneck Tube 

Figure 8a (left), b 

(center), c (right) 

Removing the outdoor 

tube adaptor (left). 

Lubricating the optical 

cover’s waterproof boot 

(center). 

Attaching the optical 

cover to the dome body 

(right). 

SFP end cap 

accessory 

 

Warning: 

Fully torque down the mounting bolt that attaches the WM02 tube 

adapter to the mounting bracket to prevent any movement of the camera due to 
wind, vibration, etc.  

Make sure the camera cannot move at all in its bracket after installation. Any 
movement of the camera in its bracket can compromise positional accuracy. 

 