Page 3: ...nel A service technician needs to install the Ecoport 800 first This quick guide does not replace the operating manual which is part of the delivery You will find further information and safety inform...

Page 4: ...st not be operated in explosive environments General Safety Information MORTAL DANGER THROUGH BLOCKED OR LEAKING EXHAUST TRACT Never operate the Ecoport inside a house or garage without a fun ctioning...

Page 5: ...s directly or permanently Instead lead them out into the open air with the supplied exhaust system Do not smoke when handling the Siqens fuel cell or Siqens fuel cartridges Keep away from heat and ign...

Page 6: ...sure that no water can penetrate the device Do not operate the Siqens fuel cell and Siqens fuel cartridges at temperatures above 50 C NOTICE Observe the safety instructions in the operating manual Fo...

Page 7: ...from heat hot surfaces sparks flames and other igni tion sources Do not smoke P210 Take precautionary measures against static discharge Do not breathe vapor P260 Store in a cool well ventilated place...

Page 8: ...edical advice immediately and show the QE CHARGE methanol cartridge label the methanol safety data sheet or the user guide Only use methanol according to the degree of purity stated in the data sheet...

Page 9: ...rotective clothing Do not touch your eyes while working on the battery Wash off acid splashes on the skin or clothing with plenty of soap and water If acid gets into your eyes rinse immediately with c...

Page 10: ...y gases Carefully lay the battery connection cable and check for improper heating under load Periodically check the battery in the area of vibrating components for chafing and insulation problems NOTI...

Page 11: ...11 Ecoport 800...

Page 12: ...Battery Connected to the Ecoport via the data cable Operated via touch display The Siqens Fuel Cell System Battery load cable with battery voltage measuring lead 16mm2 recommen ded minimum battery siz...

Page 13: ...al power peak 24V DC 0 6 l kWh Suitable for technical methanol Application range 20 C to 50 C Device can be controlled with a potential free contact Operate the Ecoport only with an exhaust system and...

Page 14: ...14 Dimensions Installation in a closed room To prevent a heat build up a distance of 50 mm must be maintained to other assembly parts on all sides Side view...

Page 15: ...15 Front view 420 341 5 350...

Page 16: ...intake kit consisting of 1x corrugated pipe 100mm approx 1 metre 2x pipe clamp 1x ventilation grille Exhaust air kit consisting of 1x corrugated pipe 100mm approx 1 metre 1x corrugated pipe 70mm appr...

Page 17: ...17 Air intake Exhaust Data interface to the control panel Methanol feed Signal connector Load plug and battery voltage measurement 24 V 141 274 2 x 100 96 184 6 89 189 223 166 28 38 23 70...

Page 18: ...d fix it with the pipe clamp Then attach the extracted aluminium corrugated pipe for supply air and exhaust air with pipe clamps Pull all three pipe clamps tight to prevent the aluminium hose from sli...

Page 19: ...800 So as to ensure a safe operation do not position the QE CHARGE methanol cartridge above the level of the Ecoport The methanol feed must be prevented from being pulled out IMPORTANT Follow the safe...

Page 20: ...tery voltage 24 V supported battery types lithium lead acid lead AGM lead gel IMPORTANT When connecting the cables be aware of the polarity The Ecoport can only operate with a battery The battery is n...

Page 21: ...21 Ecoport 800 Use the data cable to connect the operating panel with the Ecoport 800 4 Connect Control Panel to the Ecoport...

Page 22: ...22 First Installation The connection to the Ecoport 800 will be established A user input is not necessary 5 Automatic Connection between the Control Panel and the Ecoport...

Page 23: ...23 Ecoport 800 The following settings must be implemented to ensure a safe operation of the Ecoport 800 6 Start up Screen...

Page 24: ...the settings menu You can choose between Only manual Battery threshold External input When choosing Battery threshold the battery type and the turn on threshold need to be defined When choosing Extern...

Page 25: ...25 Ecoport 800 The battery type can be changed in the settings menu Select the desired battery type using the arrows Supported battery types Lithium lead acid lead AGM lead gel 8 Battery Selection...

Page 26: ...ltage threshold is reached This should not be too low since to start the system approx 100Wh are needed To prevent damage to the battery the Ecoport shuts off at a battery voltage of 23 0 V Charging t...

Page 27: ...27 Ecoport 800 Now the Ecoport 800 must be started manually 10 Initial Start of the Ecoport 800...

Page 28: ...28 First Installation The warm up phase starts automatically The Ecoport starts charging the bat tery after approx 30 minutes You can stop this procedure at any time 11 Warming up...

Page 29: ...showing the operating status appears automatically after the warm up phase The charging procedure charging phase begins For further steps please consult the information in the Operating Instruc tions...

Page 30: ...30 Symbols Go to home screen Go to settings menu Show information Show fuel tank status System Status OK Show battery status Show performance data...

Page 31: ...31 Notes Ecoport 800...

Page 32: ...452 44 63 0 Fax 49 0 89 452 44 63 22 E Mail info siqens de Web www siqens de Changes and errors excepted All technical data under test conditions of 20 C ambient temperature Status as of June 2018 20...