background image

 

WARNING.

 Read the instructions before using the machine

 

 

   

SIP Tempest 

PH720/100

 Hot 

Electric 

Pressure Washer

Code: 08958

SIP Tempest PH550/120HDS Hot / Steam Electric Pressure Washer

Code 08962

SIP Tempest PH900/200HDS Hot / Steam Electric Pressure Washer

Code: 08964

Summary of Contents for 08958

Page 1: ...before using the machine SIP Tempest PH720 100 Hot Electric Pressure Washer Code 08958 SIP Tempest PH550 120HDS Hot Steam Electric Pressure Washer Code 08962 SIP Tempest PH900 200HDS Hot Steam Electr...

Page 2: ......

Page 3: ......

Page 4: ...1 10 16 5 17 4 39 13 37 6 33 2 3 20 4 7 3 2 59 7...

Page 5: ...2 28 11 4 9 32 13 8 18 51 19 60 61 62...

Page 6: ...3 41 1 4 44 08958...

Page 7: ...5 08962 08964 41 1 4 48 4 42 45 46 47 44 49 34 53 54 56 55 1 2 56 57 58 4...

Page 8: ...8 7 6 40 39 M 25 26 50 17 52 31 36 35 43 27 29 24 24 S 22 23 52 S 22 23...

Page 9: ...10 a b 30 9 1 2 A B E D 2 1 C...

Page 10: ...lowrate l min USgpm 9 2 2 Maximumpressure bar psi 100 1450 Nominalpressure bar psi 90 1305 Maximumwateroutlettemperature C F 110 230 Maximumreactionforceonthespraygun N 21 Soundpressurelevel Uncertain...

Page 11: ...1595 190 2755 Maximumreactionforceonthespraygun N 24 45 Soundpressurelevel Uncertainty dB A 84 9 0 7 1 Soundpowerlevel dB A 92 1 Operatorhand armvibration Uncertainty m s2 2 0 0 24 1 PUMPOIL ENIMULTI...

Page 12: ...bar 464 psi it also enables steam operation only EXTRA SAFETY DEVICES Amperometric protector This safety device stops the high pressure cleaner in the event of electrical overcurrent 08962 08964 versi...

Page 13: ...Itenablesthepumpedliquidtoreturntothepump ssuctionunit preventingthedevelopment of dangerous pressure levels when the gun is closed or when a pressure value is set over the maximum level allowed Dry r...

Page 14: ...pipe in a draft tank NOTE working with a tank for pumping from is not possible with models equipped with tray Check the detergent adjustment knob 34 is closed properly Fill the appropriate tank with w...

Page 15: ...2 bar 464 psi that for pressures above 32 bar 464 psi the temperature set is no greater than 110 C 230 F If the above limits are exceeded the burner stops and the warning light 48 comes on Steam opera...

Page 16: ...for this purpose put the cap back on and check the level periodically Only use water softeners recommended by the Manufacturer STOPPING THE CLEANER TOTAL STOP MODE Release the cleaner gun lever 22 to...

Page 17: ...to clean the filter cartridge In difficult cases use a lime scale remover or replace the filter cartridge For tough cases use a lime scale remover or replace it by contacting a QUALIFIED TECHNICIAN to...

Page 18: ...ce has been tripped on the system where the cleaner is connected a fuse circuit breaker etc Reset the safety device SHOULDITTRIPAGAIN DONOTUSETHE CLEANER AND CONTACT A QUALIFIED TECHNICIAN The plug ha...

Page 19: ...in the ROUTINE MAINTENANCE paragraph The detergent is too viscose Use one of the detergents recommended by the Manufacturer anddiluteitasinstructedonthelabel No water comes out of the nozzle or flow r...

Page 20: ...USETHE CLEANER AND CONTACT A QUALIFIED TECHNICIAN The cleaner will not start up again and the warning light 45 is lit EXTRA only Thecleanerhasbeeninactivefor more than 15 minutes and has enteredTimedS...

Page 21: ......

Page 22: ...FOR HELP OR ADVICE ON THIS PRODUCT PLEASE CONTACT YOUR DISTRIBUTOR OR SIP DIRECTLY ON TEL 01509500400 EMAIL sales sip group com or technical sip group com www sip group com...

Reviews: