background image

Source: https://www.industrydocuments.ucsf.edu/docs/yzmx0000

Summary of Contents for 514-4

Page 1: ...INSTRUCTION MANUAL MODEL 514 4 ELECTRIC 230 3 60 SERIAL NO 068955 Source https www industrydocuments ucsf edu docs yzmx0000...

Page 2: ...aning solution in the drum Upon the completion of any foam cleaning using this foamer clear water should be pumped through the pump and out the wand This will greatly enhance the life and performance...

Page 3: ...in front of saray nozxle or tip 3 DO NOT alter equipment in any mannerr if repairs are necessary use only genuine factory repair parts supplied by SPRAYING SYSTEMS CO 4 DO NOT exceed mar m operating p...

Page 4: ...ularly Make 7 Do flush gun after each spray period vsing the same safety precautions as used during spraying operations Always use the lowest possible pressure for flushing 8 DD keep gun clean and dry...

Page 5: ...tank The solution tank is filled with water by opening the valve at the water in 3e let The desired quantity of Sioux Powder Cold Pressure Wash Detergent is o added prior to starting the operation an...

Page 6: ...CAPACITY WILL RESULT IN ERRATIC OPERATION UNSCHEDULED SHUTDOWNS DUE TO OVER LOAD AND FAILURE OF ELECTRICAL EQUIPMENT DUE TO OVERHEATING 2 Circuit breakers are the transitional equipment built to prov...

Page 7: ...ESSURE SHOULD NOT BE EXCESSIVE If water pressure is over 50 Pounds per square inch PSI it may not permit the float valve to seat properly and a pressure reducing valve should be installed Contact your...

Page 8: ...NG ELECTRICAL CORDS OF HEAVY DUTY GROUNDED WIRE OF SUFFICIENT WIRE SIZE TO ASSURE PROPER VOLT AGE AT THE MACHINE Alternatively equipment can be wired in direct by a qualified electrician using appropr...

Page 9: ...lution it is recommended on initial start up _ v ad us 9 Regulate amount of detergent solution required by adjusting solution valve C _ Ve 10 When ready for rinsing simply close solution valve 11 Unit...

Page 10: ...ther detergent read the following requirements carefully to helo you select a compatible pressure washer cleaning compound It must a HE FULLY DISSOLVABLE b BE NON FOAMING c CONTAIN NO ABRASIVES OR ORG...

Page 11: ...n algae and build up in water intake system and suction piping 5 Inspect pump for leaks and replace wearing parts as required Section C PU1MP MOTOR FiA FTE7ANCE Lubrication of motor should be in accor...

Page 12: ...o help solve the most common problems 1 Wire size printed on drop cord you are using Is it grounded __ 2 Length of drop cord you are using 3 Rating of circuit breaker in electrtcal system you are usin...

Page 13: ...le tips cun or hose J Remove and clean wash tips gun or hose Delime wash tips if necessary 4 Float valve upside down or not adjusted properly Orient and adjust assuring proper seating Remove foreien s...

Page 14: ...5 Inlet line not primed Prime pump c Pump air bound may occur after float tank has run dry or after pump has been removed Operate pump until fuily primed 7 Pump worn Repair or replace Check piumbing...

Page 15: ...system Pump should not be operated at more than 10 above maximum operating pressure shown on pump General Pump U S does not assume liability or responsibility for the operation of a customer s high pr...