background image

Out

TH1123ZB-G2

TH1124ZB-G2

Installation Guide

Smart Thermostat for 

Electric Heating 

Gateway connection status

Time

(provided by the gateway)

Secondary display: 

Setpoint [Set) or outside 

temperature [Out] 

Ambient temperature 

Heating indicator 

Make sure that the 

breakers for your 

heating system are 

off at the main 

electrical panel to 

avoid any risk of 

electrick shock. 

Replace the cover 

and lock

Power up the thermostat.

Unlock and lift the 

thermostat cover.

INSTALL YOUR THERMOSTAT

1

2

4

5

Out

YOUR SMART THERMOSTAT FOR ELECTRIC 

HEATING

Operatlng voltage: 

120 / 208 / 240 Vac, 60 Hz

• TH1123ZB-G2 Thermostat

Maximum load: 

12.5 A / 3000 W @ 240 Vac
12.5 A / 1500 W @ 120 Vac 

• TH1124ZB-G2 Thermostat

Maximum load: 

16.7 A / 4000 W @ 240 Vac
16.7 A / 2000 W @ 120 Vac

Minimum load: 

Baseboard, convector and radiant ceiling
2 A / 500 W @ 240 Vac
2 A / 250 W @ 120 Vac
Fan-forced convector
4.16 A / 1000 W @ 240 Vac
4.16 A / 500 W @ 120 Vac
Resistive load only

Setpoint range: 

5 ˚C to 30 ˚C (41 ˚F to 86 ˚F)

Display range:

 

0 ˚C to 50 ˚C (32 ˚F to 99 ˚F)

Resolution: 

±

 0.5 ˚C (

±

 1 ˚F)

Storage: 

-20 ˚C to 50 ˚C (-4 ˚F to 122 ˚F) 

Operation: 

0 ˚C to 50 ˚C (32 ˚F to 122 ˚F)

Protocol: 

Zigbee 3.0

Frequency:  

2.4 GHz

Transmission power: 

+20 dBm

Receiver sensitivity: 

-108 dBm

Compatible with an electric heating system such as:

• Baseboard heater [short cycle] 
• Convector [short cycle] 
• Fan-forced convector [long cycle)
• Radiant ceiling heating

TECHNICAL SPECIFICATIONS

The installation of this thermostat must be performed by a certified electrician and comply with the 

national and local electrical codes and regulations.

Warnings 

Use the connectors provided to connect the thermostat wires 

to the wires in the electrical box.

Note:

 The wires of this thermostat are non-polarized.

3

Special CO/ ALR solderless connectors must be used 

when connecting with aluminum conductors. 

Four-wire installation

Two-wire installation

 * Improperly installed electrical wires could burn the wire 

connectors.

Make sure to firmly tighten the 

wire connectors for a secure 

connection. A loose connection 

can be a fire hazard.

To install wire connectors, 

you must:

Insert the two wires into the wire nut so that their 

copper ends are parallel.

Turn the wire connector clockwise until there is 

strong tension.

Pull on the threads to make sure they are secure, 

leaving no gaps between them. * If the threads 

seem to come loose, repeat the process.

1

2

3

3/4"