background image

49

50

Explanation of symbols 

Warranty

Changsha Sinocare Inc. provides the following Warranty to the original purchaser of the 

Safe AQ UG blood glucose and uric acid monitoring system:

1. Changsha Sinocare Inc. warrants this meter to be free of defects in materials and 

workmanship from the date of purchase. If the meter does not work properly, Sinocare will 

replace it with a new meter or equivalent product free of charge. Failure of the meter due 

to abuse or use not in accordance with the instructions for use is not covered by this 

Warranty.

2. This warranty does not include the battery supplied with the meter.

3. Do not take the meter apart. This action will avoid the warranty and cause the meter to 

display false results.

4. If you meter does not work properly, please fill in warranty card carefully. Use 75% 

alcohol to clean your meter and send your meter with warranty card to your local dealer. 

References

1. American Diabetes Association Standards of medical care in diabetes-2016. 

2. Larsson-Cohn U: Difference between capillary and venous blood glucose during oral 

glucose tolerance tests. Scand J Clin Lab Invest 36:805-808, 1976
3. The Modern clinical laboratory diagnostics-test and clinical (May, 2009, version 2)

Consult instructions for use

Caution

Temperature limit

Manufacturer

In vitro diagnostic medical device

Fragile, handle with care

Keep dry

-20

55

Keep away from sunlight

Serial number

Authorized representative in the European Community

CE Marking and Notified Body Number

Biological risks

Symbol for the marking of electrical and electronics devices according to Directive 2012 /19 / EC . The device, accessories 
and packaging have to be disposed of waste correctly at the end of the usage, please follow Local Ordinance or Regulatory

for disposal.

  

Recycelbarer Abfall

Summary of Contents for Safe AQ UG

Page 1: ...nostic use only Safe AQ UG Blood Glucose and Uric Acid Meter Blood Glucose and Uric Acid Monitoring System Benutzerhandbuch Nur zur In vitro Diagnostik Safe AQ UG Blutzucker und Harns ure Blutzucker u...

Page 2: ...monitoring system This user manual contains important information about the meter and how it works Please read this user manual carefully before using your new meter or the protection provided by the...

Page 3: ...our Safe AQ UG Blood Glucose and Uric Acid meter Control Solution Testing Blood Glucose and Uric Acid Testing Viewing test result Memory Information for Healthcare Professional Use Comparing Meter wit...

Page 4: ...and uric acid meter Safe AQ UG blood glucose test strip Safe AQ UG uric acid test strip blood glucose control solution uric acid control solution Unit type Safe AQ UG Blood Glucose and Uric Acid meter...

Page 5: ...e choking hazards DO NOT drink the control solution Remove the batteries if the meter is not likely to be used for some time DO NOT CHANGE YOUR TREATMENT BASED ON A SINGLE RESULT THAT DOES NOT MATCH H...

Page 6: ...low Plasma Blood Glucose Result 100 mg dL 5 55 mmol L Fasting Plasma Glucose Male 202 mol L 416 mol L 3 4 mg dL 7 0 mg dL 142 mol L 339 mol L 2 4 mg dL 5 7 mg dL Female 1 If blood glucose test results...

Page 7: ...he blood glucose test strips here Main Button Power Set Turns the Meter on o Sets selected parameter Enter test results memory mode Up arrow Increase data LCD Display The display shows results message...

Page 8: ...with the date and time You may need to adjust it to your local time zone Check the date and time each time the batteries are replaced Reset the date and time if they are not correct STEP 1 Insert the...

Page 9: ...e meter will turn on The meter enters into the Date Time mode 2 It displays date and time the segment of year flashes Step 1 With the meter turned o press and hold for 3 seconds to start Time and Date...

Page 10: ...onth Step 1 Press and release or to decrease or increase the month Step 2 Short press and release the main button to con rm the month STEP 6 Setting the Day The day appears flashing at the left side o...

Page 11: ...crease or increase the hour Step 2 Short press and release to con rm the hour STEP 8 Setting the Minutes The minutes appear flashing at the lower left side of meter display 1 Press and release or to d...

Page 12: ...tion Testing Why Perform a Control Solution Test Ensures that your meter and test strips are working properly Allows you to practice testing without using blood When Should You Perform a Control Solut...

Page 13: ...g blood drop symbol and control bottle symbol can you apply control solution If there is no blood drop symbol or control bottle symbol restart the meter again or change the test mode STEP 3 Apply the...

Page 14: ...test Temperature is too high or too low Wrong correcting code Equilibrate meter test strip and control solution in room temperature for 30 minutes and retest Set correcting code which accordance with...

Page 15: ...ge skin 5 deepest depth for thick or calloused skin The Sinocare lancing device is prepared and ready to lance your nger for a blood sample The lancet is for single use only To prevent the risk of blo...

Page 16: ...will not turn on The meter can test blood glucose and uric acid together STEP 10 Take Blood Sample Make sure the lancing device is pressed rmly to your nger Press the button to lance Attention If you...

Page 17: ...ric acid testing After a 25 second count down the meter displays the test result in mg dL or mol L STEP 13 Eject the strip Used test strip and lancet may be biohazardous Please discard them carefully...

Page 18: ...ter than 33 3mmol L 600 mg dL the meter will display HI Retest immediately with a new test strip If your reading is still HI contact healthcare professional immediately If blood glucose test results l...

Page 19: ...sult is dropped and the newest is added Press the or button to view all the blood glucose results in memory When you have viewed all test results meter will display End press and hold the for 3 second...

Page 20: ...professional be allowed to collect venous blood samples Any patient who has infectious diseases must use his her own meter If the same meter be used on multiple patients there is risk of infection bet...

Page 21: ...oughly again after handing meter 5 Verify the meter is working properly by performing control solution test If your meter can t work properly please contact customer service at 86 731 89935581 86 731...

Page 22: ...cose About 0 6 L Blood volume for uric acid About 3 L Sample type Capillary whole blood Venous whole blood Calibration Plasma equivalent Measuring time for blood glucose 5 1s Measuring time for uric a...

Page 23: ...ay cause erroneous results Electromagnetic Compatibility EMC The meter complies with the electromagnetic requirements IEC 61326 2 6 2012 speci ed in ISO 15197 2013 Electromagnetic emissions are low an...

Page 24: ...sional immediately Use a new test strip to test again if meter still display LO call healthcare professional immediately Display What it means What to do Your blood glucose test result is below the me...

Page 25: ...p to test again Test method error insert strip into meter after apply sample to strip Use a new test strip to test again Use a new test strip to test again Test strip exposed to air more than 3 minute...

Page 26: ...right port when insert the test strips The blood glucose test strip insert into port marked with G The uric acid test strip insert into port marked with U Test strip Inserts into wrong ports Poor con...

Page 27: ...new test strip The test strip is exposed in moisture environment for too long Display What it means What to do without sample applied to test starts and meter counts down as soon as the test strip is...

Page 28: ...ard carefully Use 75 alcohol to clean your meter and send your meter with warranty card to your local dealer References 1 American Diabetes Association Standards of medical care in diabetes 2016 2 Lar...

Page 29: ...intenance 40 Change battery 41 Troubleshooting 42 Symbol 49 Warranty 50 Thank you for choosing Safe AQ UG blood glucose meter a free replacement under normal operation is provided Please do complete t...

Page 30: ...53...

Page 31: ...Tech Zone Changsha Hunan Province 410205 People s Republic of China Tel 86 731 89935581 89935582 Fax 86 731 89825189 Email info sinocare com Website www sinocare com Ei estra e 80 20537 Hamburg German...

Reviews: