GTJZ0612E&0812E&1012E&1212E Maintenance Manual
1-7
© Jul.2020
MEASURE
GTJZ1212E (METRIC)
4047E (IMPERIAL)
Hydraulic tank capacity
15L
3.3 gal(imperial)/4 gal(US)
Hydraulic system capacity (including tank)
34L
7.5 gal(imperial)/9 gal(US)
Hydraulic system pressure
21MPa
3046 Psi
Battery specification (quantity × voltage,
capacity)
4×6V,240Ah
System voltage
24VDC
Control voltage
24VDC
ENVIRONMENTAL REQUIREMENT
Max. allowable wind speed (indoor/
outdoor)
0 m/s(indoor)/12.5 m/s(outdoor)
0 mph(indoor)/28mph(outdoor)
Max. allowable altitude
1000m
3281ft
Allowable ambient temperature (lead-acid
batteries)
-10
℃
to 40
℃
14
℉
to 104
℉
Allowable ambient temperature (lithium
batteries)
-20
℃
to 40
℃
-4
℉
to 104
℉
Max. allowable ambient relative humidity
90%
Storage condition
Stored at -20
℃
to 50
℃
(-4
℉
to 122
℉
) in a well-ventilated environ-
ment with 90% relative humidity (20
℃
[68
℉
]), and away from rain,
sun, corrosive gas and inflammable explosive.
WEIGHT
Weight (in a no-load state) (indoor/
outdoor)
3210kg
7077 lb
Weight (in a no-load state) (indoor only)
3100kg
6834 lb
NOTE:
a) The working height adds 2m (6ft 7in) of human height to platform height.
b) In different areas, hydraulic oil, engine oil, coolant, fuel and lubrication should be added in accordance with the
environmental temperature.
c) In cold weather, auxiliary devices are needed to start the machines.
POWER SYSTEM SPECIFICATIONS
Table 1-5
MEASURE
SPECIFICATIONS
HYDRAULIC OIL
Normal temperature region (32°F ~ 104°F [0°C ~ 40°C])
L-HM46
Cold region (-13°F ~ 77°F [-25°C ~ 25°C])
L-HV32
Hot region (>104°F [40°C])
L-HM68
Extremely cold region (<-22°F [-30°C])
Special scheme to be determined
Summary of Contents for GTJZ0612E
Page 2: ......
Page 6: ...This Page Intentionally Left Blank...
Page 8: ...This Page Intentionally Left Blank...
Page 12: ...Jul 2020 iv GTJZ0612E 0812E 1012E 1212E Maintenance Manual This Page Intentionally Left Blank...
Page 86: ...Jul 2020 5 28 GTJZ0612E 0812E 1012E 1212E Maintenance Manual MAINTENANCE PROCEDURES...