USER'S MANUAL

ASD-09A, ASD-12A, ASD-18A, ASD-24A

DUCT SERIES

ASD-36A, ASD-41A, ASD-60A

Summary of Contents for DUCT ASD-09A

Page 1: ...USER S MANUAL ASD 09A ASD 12A ASD 18A ASD 24A DUCT SERIES ASD 36A ASD 41A ASD 60A ...

Page 2: ......

Page 3: ...er 11 Unit Function 14 Weekly Timer 14 Operating Instructions Dual Sensor Setting 15 Installation Dimension of Indoor Unit 17 Installation of Outdoor Unit 19 Precautions on Installation of Indoor Unit and Outdoor Unit 20 Indoor Unit Level Inspection and Air Duct Installation 21 Installation and Test of Condensing Water Pipe and Selection of Connecting Pipe 22 Installation of Connecting Pipe 22 Pos...

Page 4: ...cation of the air conditioner The appliance shall not be installed in the laundry WARNING Before installation please check the power supply for compliance with the ratings on nameplate Check the power safety as well Before use please check and confirm if the cables drainage pipes and pipelines are correctly connected hence to eliminate the risk of water leakage refrigerant leakage electric shock o...

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ...d the unit shall operate according to the new fresh air setting The default setting of the system is 0 when the unit is shipped out from manufacturer so the fresh air value is shut off Now if you start up the unit the LCD does not display the work FRESH If user sets one type of fresh air operation the LCD shall always display the word FRESH regardless of the operating mode after the unit is start ...

Page 9: ...oling limit is set as 23 C and the upper cooling limit is set as 27 C for the energy saving temperature setting in Figure 9 so the cooling temperature can only be selected from the range of 23 C to 27 C by using the remote controller or the wire controller later If the upper limit temperature is the same as the lower limit temperature the system can only operate at such temperature under relevant ...

Page 10: ......

Page 11: ...ilure of Indoor Room Sensor at Air Intake E1 Compressor High Pressure Protection F1 Failure of Evaporator Temp Sensor E2 Indoor Frost Proof Protection F2 Failure of Condenser Temp Sensor E3 Compressor Low Pressure Protection F3 Failure of Outdoor Ambient Sensor E4 Compressor Exhaust High Temperature Protection F4 Failure of Exhaust Temp Sensor E5 Compressor Overload Protection F5 Failure of Indoor...

Page 12: ......

Page 13: ...oom Refer to Figure 17 22 SWING AUTO o C SWING FAN SPEED MODE ON OFF 22 SWING AUTO o C SWING FAN SPEED MODE ON OFF ON OFF MODE FAN SPEED SWING C o AUTO SWING 22 ON OFF MODE FAN SPEED SWING C o AUTO SWING 22 Fan Mode Operation Connect the unit to power supply Press the ON OFF key Press the MODE key to select FAN mode The unit shall operate under FAN mode Press the FAN key to select from high medium...

Page 14: ...mote control is not in use for a longtime to avoid malfunction caused by liquid leakage 5 The remote control should be placed about 1m or more from the TV set or any other electric appliances 6 The remote control should be used in the receivable range the reception range is 10m 7 When the remote control can not be controlled in the situation of inserted batteries please remove the back cover and p...

Page 15: ...e fully automatic operation No timing control can be set for holidays Fig 20 This WEEKLY TIMER adopts 485 mode to communicate with manual control of every duct type unit and it can control up to 16 units Adopting 2 core twisted pair wire the longest communication distance of this TIMER is 1200m After connected to power the WEEKLY TIMER can display all connected units sequence of unit is determined...

Page 16: ...mes in a day in one week and on off setting can be done by pressing on off button 3 Connection between WEEKLY TIMER and manual control is shown as following 2 Setting of Double Indoor Room Sensors This series of ducted air conditioning unit has two indoor room sensors One is located at the air intake of the indoor unit and the other one is located inside the wire controller User can select one fro...

Page 17: ...goes into effect at any time and features very simple operation Refer to the section of wire controller instructions for detailed operation Fresh Air Air Supply Pipe Air Intake Pipe Indoor Side Air Valve Outdoor Fresh Air Before startup the unit please remove all the sealing film on the healthy filter block Fig 24 4 The head of delivery of the condensate drainage pump can reach 1 1m so that the en...

Page 18: ... Dimensions of Indoor Unit Air Intake Drainage Pipe Electric Box G as Pipe Liquid Pipe Air Intake F I Be suit for ASD 09A ASD 12A ASD 18A Fig 26 D C A B F G H I J Drainage Pipe Gas Pipe Liquid Pipe Electric Box Air Intake E Be suit for ASD 24A ASD 36A ASD41A ASD 60A Fig 27 17 ...

Page 19: ...7 207 276 1 4 1 2 ф30 1 5 ASD 24A 1063 505 849 1159 1270 504 1088 202 211 268 3 8 5 8 ф20 1 5 ASD 36A ASD 41A 1011 748 820 1115 1251 744 1047 160 231 290 1 2 3 4 ф20 1 5 1015 784 825 1115 1251 788 1051 285 258 330 1 2 7 8 ф32 1 5 Dimension Requirement of the Installation Space of Indoor Unit Nut with Washer Nut Spring Washer Be suit for ASD 09A ASD 12A ASD 18A Fig 28 Be suit for ASD 24A ASD 36A AS...

Page 20: ...2 E 286 378 378 378 1 Outdoor unit shall be installed so that the air discharged by outdoor unit will not return and that sufficient space for repair shall be provided around the machine 2 The installation site must have good ventilation so that the outdoor unit can take in and exhaust enough air Ensure that there is no obstacle for the air intake and exhaust of the outdoor unit If there is any ob...

Page 21: ...rovide enough space for the service and maintenance 5 The installation site must be far away from heat source leakage of inflammable gas or smoke 6 The indoor unit is of ceiling mount indoor unit is hidden inside the ceiling 7 The indoor and outdoor units the power cable and the connecting electrical lines must be at least 1 meter from any TV set or radio This is to avoid image interference or noi...

Page 22: ... unit at the beam and fix it Level Check of the Indoor Unit After the indoor unit is installed it is required to check the level of the whole unit The unit must be placed horizontally but the condensate pipe shall be installed obliquely so as to facilitate the drainage of condensate Air Supply Air Intake i Condensate Drainpipe Level Instrument Enlarged View Condensate Drainpipe As the inside of th...

Page 23: ...ate pipe shall be installed with an inclining angel of 5 10 so as to facilitate the drainage of condensate The joints of the condensate pipe must be covered by thermal insulation materials to avoid generation of exterior condensate As shown in Figure 23 2 A condensate outlet is located at both the left and right sides of the indoor unit After selecting one condensate outlet the other outlet shall ...

Page 24: ... Fitting Pipe Inch Item Model Gas Pipe Liquid Pipe Max Pipe Length m Max Height Difference between Indoor Unit and Outdoor Unit m Amount of Additional Refrigerant to be Filled For Extra Length of Pipe ASD 09A 3 8 ASD 12A ASD 18A 1 2 1 4 20 15 30g m ASD 24A 3 8 5 8 30 15 60g m ASD 36A ASD 41A 1 2 3 4 50 30 120g m ASD 60A 1 2 7 8 50 30 120g m Note 1 The standard pipe length is 5m When the length L o...

Page 25: ... N m 3 The bending angle of the fitting pipe shall not be too small and otherwise the pipe may break Please use a bender when bending the fitting pipes 4 Use sponge to wrap the connecting pipe and joint without thermal insulation and use plastic tape to bundle the sponge 5 Remove the bonnets of the liquid valve and the gas valve 6 Use an inner hexagon spanner to turn the spool of the liquid valve ...

Page 26: ...ipe 1 To avoid generation of condensate on the connecting pipe and avoid leakage the big pipe and the small pipe of the connecting pipe must be covered by thermal insulation materials be bundled by adhesive tape and be isolated from air 2 The joint connecting to the indoor unit must be wrapped by thermal insulation material There shall be no gap between the connecting pipe joint and the wall of th...

Page 27: ...control wire should be metallic substance The manual controller could not be disassembled and the communication wire be used for the manual controller should not be changed by users optionally the installation and maintenance should be carried out by the professional personnel 2 First select an installation position According to the size of the communication line of the wire controller leave a rec...

Page 28: ...ew M4X10 4 Panel of Wire Controller Caution 1 The communication distance between the main board and the wire controller is 8 meters 2 The wire controller shall not be installed in a place where there is water drop or large amount of water vapor Caution 1 ASD 24A can be connected only to a supply with system impedance no more than 0 211 ohm In case necessary please consult your supply authority for...

Page 29: ...nal of the multiple twisted wires and fix the terminal at the terminal board Warning If the power supply flexible line or the signal line of the equipment is damaged only use special flexible line to replace it 1 Before connecting lines read the voltages of the relevant parts on the nameplate Then carry out line connection according to the schematic diagram 2 The air conditioning unit shall have s...

Page 30: ...outdoor unit 3 Pass the cable though rubber ring 4 Connect the power cable to the terminal and earthing screws marked L1 L2 L3 N 5 Use cable fastener to bundle and fix the cable 3 FASD 18A This model should be connected only to a supply with the relevant system impedance no more than Zmax 0 27 j0 17 ohm In case necessary please consult supply authority for system impedance information ASD 12A This...

Page 31: ......

Page 32: ...red 4 There is refrigerant leakage 5 The outdoor ambient temperature is lower than 5 6 Control line is abnormal The indoor fan does not start under the heating mode 1 The installation site of the tube sensor is not proper 2 Tube sensor is not correctly plugged 3 The connecting line of the tube sensor is broken 4 The capacitance has leakage Note After carrying out the check of the above items and t...

Page 33: ...e if the line connection is in good condition 4 Check if there is any word displaying on the LCD of the wire controller after connecting the unit to power supply Note If there is any abnormal condition ask aftersales personnel to offer guidance 3 Maintenance at the End of the Operational Season 1 When the weather is clear operate the unit under fan mode for half a day so as to dry the inside of th...

Page 34: ... mm 950 950 Depth mm 412 412 Height mm 840 1250 Wt kg 90 123 mm ф32 1 5 ф20 1 5 ф20 1 5 950 412 700 59 268 1251 56 37 11 4 8000 2800 2400 13 2 ф1 2 ф1 4 Model Item Heat pump type ф3 4 380V 415V 3N 50Hz 150 Power Supply Compressor 7000 Drainage pipe diameter interior X exterior Noise Indoor Unit Outdoor Unit Name of Refrigerant Filled Amount of Refrigerant Indoor Outdoor Connec ting Static Air Pres...

Page 35: ... measured at the relevant standard external static pressure 3 Cooling heating capacity stated above is measured under nominal working conditions corresponding to standard external static pressure The parameters are subject to change with the improvement of products in which case the values on nameplate shall prevail 4 The cooling heating capacity is measured at the nominal work conditions with the...

Page 36: ...ANT CHARGE Pursuant to Regulation EC 842 2006 on certain fluorinated greenhouse gases in case of extra refrigerant charge it is compulsory to Fill in the label accompanying the unit inserting the factory quantity of refrigerant charge see the technical label the extra refrigerant charge and the total charge Apply the label next to the technical label applied on the unit For the split type air cond...

Page 37: ...This product must not be disposed together with the domestic waste This product has to be disposed at an authorized place for recycling of electrical and electronic appliances 66175604 36 ...