MultiXplo / MultiTox
Page 10 / 60
NOSP15759-Rev 10
1.5.
Detection Cartridge
Detection Cartridges are explosion proof designed.
They are common to all Oldham Simtronics MultiXplo and MultiTox-K products in order to
reduce the number of spare parts.
•
DM-RX6-X and DM-RT6-K: Network versions for Syntel loop,
•
DM-TX6-X and DM-TT6-K: « Telecapteur » versions,
For combustible gas detector’s cartridges, if the difference between the storage temperature
and the operating temperature does not exceed 20°C, the nominal characteristics are
obtained after a few minutes. Otherwise, wait for the balancing thermal unit, about half an
hour.
Catharometer cartridges (cartridges K) need to be in thermal balance with their environment
to provide nominal performance. Thus, when the cartridges have been unpowered more than
half-an-hour, a warm-up time is required when power is restored. The duration of warm-up
is usually range from ½ hour to 4 hours, depending on the temperature difference between
the cartridge and the ambient temperature.
The cartridge temperature information is available on the TLU.
The cartridge must not be unplugged when the detector is powered.
1.6.
Communication interfaces
1.6.1.
Wireless Configuration Tool
Information and status of the detector are available via the wireless configuration tool
TLU600.
Configuration and tests are performed using this wireless configuration tool (IrDA protocol).
This tool is common for all Oldham Simtronics MultiFlame, MultiXplo
and MultiTox products.
The TLU600 provides access to devices, which would otherwise
require major logistic operations for maintenance or for
configuration (calibration …).
For more details, please refer to the wireless configuration tool
operating manual.
Summary of Contents for DM-TT6-K
Page 9: ...MultiXplo MultiTox Page 9 60 NOSP15759 Rev 10 Figure 1 Layout Drawing Congestion see Figure 2...
Page 32: ...MultiXplo MultiTox Page 32 60 NOSP15759 Rev 10...
Page 48: ...MultiXplo MultiTox Page 48 60 NOSP15759 Rev 10...
Page 56: ...MultiXplo MultiTox Page 56 60 NOSP15759 Rev 10 10 CONFORMITY CERTIFICATE...
Page 57: ...MultiXplo MultiTox Page 57 60 NOSP15759 Rev 10...
Page 58: ...MultiXplo MultiTox Page 58 60 NOSP15759 Rev 10...
Page 59: ...MultiXplo MultiTox Page 59 60 NOSP15759 Rev 10...