974-25007001/2.0
SL 30/35 Hull Sonar Operators Manual
Page 6.12
Installation, Start-Up and Test
Kongsberg Simrad Mesotech Ltd.
Port Coquitlam, BC - Canada
Shaft Lock Nut
Tank Guide
Tank Flange Gasket
Flange Assembly
Shaft Packing Retainer
Mounting Hex. Bolts
and Spring Washer
Mounting Hex. Bolts, Flat Washers,
Spring Washers and Nuts
Shaft Packing
Soundome Cable
Main Shaft
Shaft Packing
Cut at a 45 degree angle and space
120 degrees apart
Sonar Dome, Shaft and Tank
Guide Assembly
Bow
Bow Mark
"V" Guide Heading Alignment Block
and Shaft Retainer
Cable Gland
Zinc Anode
See Part 8
“Attachments and Drawings”
for detailed assembly drawings.
6.4.4 Mounting the Flange and Sonar Dome to the Tank (Trunk)
Before lowering the sonar dome and flange assembly in position:
•
Clean the top of the tank flange to remove any grease or rust buildup
•
Apply a coat of “Loctite 2”, gasket sealant supplied with the system
•
Position the flange gasket and apply a coat of “Loctite 2” gasket sealant to the
top of the gasket; lower the flange and sonar dome assembly into the retraction