Checking the operation of the Hoisting and Lowering
contactors
The
Hoisting Contactor
(K301) and the
Lowering Contactor
(K302) are located on the
upper DIN rail in the Motor Control Unit. Each contactor operates on +24 VDC supplied
by the internal power supply. When activated,
Hoisting Contactor
(K301) starts the
motor in order to retract the transducer. The
Lowering Contactor
(K302) starts the motor
to lower the transducer.
Prerequisites
Before you can do this task, the
following prerequisites must be met:
• The SC90 is turned off.
• The circuit breaker for the 3-phase
AC power is closed. AC power
is connected.
• The transducer is in its upper
position with the
Upper Limit
Switch
(S304) activated.
You must be equipped with a
standard set of tools. This tool set
must comprise the normal tools for
electronic and electromechanical
tasks. This includes different
screwdriver types, pliers, spanners,
a cable stripper, a soldering iron
etc. Each tool must be provided in
various sizes. We recommend that
all tools are demagnetized to protect
your equipment.
Context
The following conditions must be set to activate
Hoisting Contactor
(K301):
• The
Hoist/Lower Switch
(S302) must be set to
HOIST
or
REMOTE
.
• The
Lowering Contactor
(K302) must be deactivated.
• The
Upper Limit Switch
(S304) must be deactivated with the transducer in lower
position or on its way up.
• The
Hand Crank Switch
(S203) must be closed with the hand crank in its storage
position.
The following conditions must be set to activate
Lowering Contactor
(K302):
• The
Hoist/Lower Switch
(S302) must be set to
LOWER
or
REMOTE
.
• The
Hoisting Contactor
(K301) must be deactivated.
Summary of Contents for SC90
Page 2: ......
Page 16: ...14 419050 B Simrad SC90 ...
Page 219: ...419050 B 217 Øverland UPC 3005 Dimensions Cable layout and interconnections ...
Page 223: ...419050 B 221 Øverland UPC 5000P Dimensions Cable layout and interconnections ...
Page 438: ...436 419050 B 427177 Transducer dock dimensions page 494 Simrad SC90 Installation Manual ...
Page 441: ...419050 B 439 Drawing file ...
Page 442: ...440 419050 B Simrad SC90 Installation Manual ...
Page 445: ...419050 B 443 Drawing file ...
Page 452: ...450 419050 B Simrad SC90 Installation Manual ...
Page 455: ...419050 B 453 Drawing file ...
Page 458: ...456 419050 B Simrad SC90 Installation Manual ...
Page 463: ...419050 B 461 Drawing file ...
Page 468: ...466 419050 B Simrad SC90 Installation Manual ...
Page 469: ...419050 B 467 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 471: ...419050 B 469 Drawing file ...
Page 473: ...419050 B 471 214043 Gate valve installation DN350 Drawing file ...
Page 475: ...419050 B 473 422915 Gate valve installation DN350 Drawing file ...
Page 477: ...419050 B 475 083045 Gate valve installation DN500 Drawing file ...
Page 479: ...419050 B 477 33414 Gate valve dimensions DN350 Drawing file ...
Page 480: ...478 419050 B Simrad SC90 Installation Manual ...
Page 481: ...419050 B 479 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 482: ...480 419050 B 33473 Gate valve dimensions DN350 Simrad SC90 Installation Manual ...
Page 483: ...419050 B 481 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 484: ...482 419050 B 33498 Gate valve dimensions DN500 Simrad SC90 Installation Manual ...
Page 485: ...419050 B 483 Drawing file ...
Page 487: ...419050 B 485 37357 Gate valve dimensions DN500 Drawing file ...
Page 488: ...486 419050 B Simrad SC90 Installation Manual ...
Page 489: ...419050 B 487 Related topics Installing the optional gate valve DN500 page 103 Drawing file ...
Page 491: ...419050 B 489 Drawing file ...
Page 494: ...492 419050 B Simrad SC90 Installation Manual ...
Page 495: ...419050 B 493 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 497: ...419050 B 495 Drawing file ...
Page 542: ... 2018Kongsberg Maritime ISBN xxx ...
Page 543: ......
Page 544: ...Simrad SC90 Fish finding sonar Installation Manual ...