Simrad PI REMOTE - REV A Quick Reference Manual Download Page 1

C

(CD012201B)

A

B

D

E

Quick reference guide
Simrad PI Remote/Depth dual sensor

Purpose

The purpose of the 

PI Remote/

Depth

 sensor is to achieve accurate 

measurements of both the water depth 

and the distance between the two 

trawl doors. In order to measure the 

distance, it must be installed in a pair 

with a PI Spread or PI Spread/Depth 

sensor.

The adapter used to install the PI 

Remote/Depth sensor is not the same 

as the adapter used for the standard PI 

Remote sensor.

Daily operation

The PI Remote/Depth dual sensor 

will automatically be switched on 

once the waterswitch is activated. 

After startup, the sensor will 

communicate with the PI Spread 

sensor to measure the distance 

between the two trawl doors. The 

current depth result is transmitted 

directly to the vessel.

When the sensor is not in use, check 

that the sensor lamp does not flash, 

as this indicates that the sensor is still 

active and discharging the batteries.

If you operate with 

Fast

 update 

rate, the sensors must be charged 

approximately every 40 hours. Used 

with 

Normal

 or 

Slow

 update rates, the 

operational life is approximately 80 or 

110 hours respectively. The optimal 

sensor charging temperature is from 

+10 to +25° C.

Note: Charging sensors at sub-zero 

temperatures can create explosive 

gasses. Simrad assumes no liability 

for the improper charging of 

sensors or the use of chargers not 

specified in Simrad’s sensor charging 

documentation.

The two rubber inserts provided at 

the bottom of each sensor adapter 

must not be replaced with any other 

types or designs. It is essential that 

these inserts provide a secure cradle 

for the sensors, but they must also 

allow for free water circulation to 

allow the sensor’s water switch to 

engage. Also, the design of the inserts 

allows sand and mud to flow out when 

the trawl doors are pulled up from the 

water.

B

C

E

D

F

G

A

(CD012201A)

Main items

(A) Negative charging & fastening lug

(B) Positive charging & fastening lug

(C) Communication link to the vessel

(D) Transverse communication link

 (E) Spread and Remote set 

identification

(F) Water switch with sacrificial bolt

(G) Sensor identification label

(A) The Spread sensor is mounted in a special adapter on the port trawl door.

(B) The Remote/Depth sensor is mounted in an adapter on the starboard door.

(C) The Spread sensor communicates the distance between the trawl doors to 

the PI system on the vessel.

(D) The Remote/Depth sensor communicates the current depth of the trawl door 

to the PI system on the vessel.

(E) Using the transverse communication link, the two

sensors measure the distance between the trawl doors.

Sensor configuration

On delivery, all Spread sensors are 

configured as follows:

Remote: 

Remote 1

Depth: 

Channel 11, 15 or 13 / Fast

Note: The sensor and the PI system 

setup must correspond, otherwise the 

communication will not work.

To change the setup, use the 

PI 

Configurator

 utility.

The sensor update rate controls how 

often the sensor reads and reports the  

depth. Three settings are available; 

Fast, Normal and Slow. Note that a 

faster update rate will decrease the 

battery life.