3 options are available:
•
No association
•
AIS priority association
•
ARPA priority association.
It is possible to change the selected option at any time, but only operating in the Monitoring
station mode.
•
Selected option is displayed in target console (SLP/ASC).
•
Display of associated targets is done according to current standard.
Name of associated target displayed on the chart in brackets after the name of main target.
This makes possible to get access to appropriate target properties in the target table. In the
target table no association is used and data is displayed as it is.
Lost target alert
This alert is warning.
Ú
Note:
The alert is available when the CPA/TCPA alarm function is enabled.
Press button to configure alert when a target is lost within a given Range around ship
position. This alert is available for both AIS and ARPA targets.
1.
Press the Lost target button to open the dialog
2.
Check box to activate alert
3.
Set the value of the range
Ú
Note:
When the alert is active, lost targets are not removed automatically from the list
after normal timeout (1 min). Alert acknowledgment will remove lost targets from the
list.
146
Automatic Identification System (AIS)
| ECDIS900 Operator
Manual