Page 16
MARIS ECDIS900 Installation Manual
Category B alerts
Information
Type
Position system failure
W
Gyro failure
W
STW failure
W
Different geodetic datum. (If the local datum on the GPS is
different from the WGS-84 datum, a warning is generated.)
W
Note: The ECDIS900 doesn’t handle Emergency alarms, or category C alerts.
ALERT ID AND TEXT
When BAM is connected by serial line to the Monitor station, the ECDIS900 sends alarms,
warnings and cautions to the BAMS.
The alert titles sent to BAM may be shorter and slightly different from the alert text displayed
on the ECDIS900.
ALERT TITLES AND ALERT IDs SENT TO BAM
Alert title
Alert ID
Back up navigator
99
Different geodetic datum
3005
Position system failure
3015
Failure of GYRO
3016
Master GPS changed
3017
Failure of STW
3018
Dev from pld route off-trk alm
3024
End of track
3025
Early COG change indication
3027
Crossing safety contour
3030
Anchor watch - (Alarm)
3033
Anchor watch - (Warning)
3032
Area with spec. conds
3035
Crossing navig. hazard
3037
Approach critical point
3038
User object alarm
3040
Target capacity exceeded
3042
CPA-TCPA
3044
Summary of Contents for Maris ECDIS900
Page 1: ...ENGLISH Maris ECDIS900System Installation Manual www navico commercial com ...
Page 40: ...Page 40 MARIS ECDIS900 Installation Manual ECDISMK15 MECHANICAL DRAWINGS ...
Page 41: ...Page 41 MARIS ECDIS900 Installation Manual DIMENSIONAL DRAWINGS FOR 19 TERMINAL LAYOUT FOR 19 ...
Page 42: ...Page 42 MARIS ECDIS900 Installation Manual DIMENSIONAL DRAWINGS FOR 24 TERMINAL LAYOUT FOR 24 ...
Page 44: ...Page 44 MARIS ECDIS900 Installation Manual HATTELAND MONITORHD26T21 ECDIS900 PCMK5 ...
Page 63: ......