Operational procedures
The biomass is automatically calculated based on choices you make in the
Calculation Interval
dialog; within a given time frame, a defined number of pings, or
a portion of the echogram view. The data is then taken from an echo area starting
immediately after the transmit pulse, and ending just over the detected depth. If
you have limited your vertical range (using the
Range
and
Start Range
settings),
the resulting area is used for the biomass calculation. If the seabed is clearly
defined with a unique bottom detection, the bottom echo will not be included in the
calculations. Therefore, if you switch the bottom detector off, the bottom echo will
be included in the calculation.
→
on page 59
b
Bottom
The echogram is related to the detected bottom. Stop depth (lower echogram
boundary) and vertical range are manually selected by the
Start Depth
and
Range
buttons on the
Main
menu. The echogram is only drawn for pings having a
successful bottom detection.
The biomass calculation is made in the same way as for
Surface
echograms.
c
Pelagic
This echogram is nearly identical to the
Surface
echogram. However, the biomass is
calculated in a different manner.
The biomass calculations are not restricted by the bottom detection. This means that
the bottom echo will be included in calculations if it appears within the chosen range.
Example 9
Biomass calculation
If you are investigating a large school of pelagic fish, set the
Start Range
and
Range
to enclose the school. If the school is large enough, a
Surface
echogram may mistake it for bottom, and the biomass readings will
be wrong. The
Pelagic
echogram will however disregard the bottom
detection, and give a correct estimate of the biomass.
d
Trawl
This echogram covers the vertical opening of the trawl.
The echogram is only drawn when trawl position information is available.
The biomass calculation is made in the same way as for
Surface
echograms.
This procedure explains how to choose the echogram type you wish to see.
1
Click the
Active
icon under the
Main
menu to open the
Active
menu.
→
on page 107
2
Click
Echogram
to open the
Echogram
dialog.
343539/B