How to install the transducer
Example: Large transducer
The illustration below shows a typical transducer blister designed
for a large transducer. Note that due to the physical size of
the transducer, a U-shaped support bar (E) is used to support
the transducer. The purpose of this support is to prevent the
transducer from being pushed up into the blister in heavy seas.
(CD017010A)
H
E
E
K
G
B
D
A
C
F
J
I
A
Streamlined blister
B
Stiffening rib
C
Drainage holes
D
Inclination angle
E
U-shaped support bar (on large transducers)
F
Forward
G
Cable service loop
H
Stuffing tube
I
Minimum 400 mm
J
Rounded corners
K
Air outlet
329786/A