40
330254/B
Splicing the cable using a grounded junction box
Context
Do not solder the wires together with only electrical tape for insulation. This will result in
electrical noise and reduced operational performance.
A
Junction box
B
Cable gland
C
Terminal block
D
Cable
E
Cable screen
F
May be connected to ship’s ground
Procedure
1
Mount the junction box in a suitable
location.
2
Terminate the steel conduits containing
the transducer cables to the housing of
the junction box or end these as close to
junction box as possible.
3
Feed the cables through the cable glands.
4
Remove the insulation from the each cable and connect the individual conductors to
the terminal block.
5
Connect the screen of both ends of the transducer cable together.
6
The screen of the transducer cables must not have electrical connection to the junction
box housing or cable gland, insulate if necessary.
Related topics
ES120-7C Connecting to a 12-pin Amphenol socket, page 46
12-pin Amphenol plug , page 49
Splicing the cable using a junction box isolated from vessel’s
ground
Context
Do not solder the wires together with only electrical tape for insulation. This will result in
electrical noise and reduced operational performance.