66
404770/B
Mount the transducer at forward part of
hull to minimize the effects from the flow
boundary water layer
The upper water layers of the sea contain a myriad of small air bubbles created by the
breaking waves. When the hull moves through water it will cause a disturbance, and this
will generate friction. The friction zone is called the
flow boundary layer
.
The flow in this boundary layer may be
laminar
or
turbulent
.
• The
laminar
flow is a nicely ordered, parallel movement of the water.
• The
turbulent
flow is a disorderly flow pattern, full of eddies.
A
Turbulent flow
B
Laminar flow
C
Air bubbles
Air bubbles absorb and reflect the sound energy, and they may in worst cases block the
sound transmission altogether.
The boundary layer increases in thickness when it becomes turbulent. The boundary
layer is thin in the forward part of the vessel hull, and increases as it moves aft. The
thickness depends on ships speed and on the roughness of the hull. All objects sticking
out from the hull, or dents in the hull, will disturb the flow and will increase the thickness
of the boundary layer. When the flow speed is high, the turbulence can be violent enough
to destroy the integrity of the water. Small voids or cavities in the water will occur and
this is called cavitation.
It is our experience that a wide and flat bottom, with a rising angle less than around 13
degrees, is prone to giving air problems for the transducer. In any case a transducer
location in the forward part of the hull is preferred in order to minimise the influence of
the boundary layer.
Related topics
Where to install the transducer, page 63
Simrad ES18 Installation Manual
Summary of Contents for ES 18 - DATASHEET REV C
Page 2: ......
Page 75: ...404770 B 73 Related topics Drawing file page 70 Drawing file...
Page 77: ...404770 B 75 Drawing file...
Page 78: ...76 404770 B Related topics Drawing file page 70 Simrad ES18 Installation Manual...
Page 80: ...78 404770 B Related topics Drawing file page 70 Simrad ES18 Installation Manual...
Page 82: ...80 404770 B Related topics Drawing file page 70 Simrad ES18 Installation Manual...
Page 87: ......
Page 88: ...2020 Kongsberg Maritime...