selectable NMEA 

 
The Selectable NMEA feature allows control over which sentences are received and transmitted by the h1000 
Universal Interface. This gives flexibility when interfacing to other manufacturers’ products such as radars and 

chart-plotters. Selectable NMEA allows you to filter out unwanted NMEA messages and prevents duplicated data 
on the system. 
 

3rd Party

Pilot

3rd  Party

GPS

3rd  Party R adar

Plo tter/GPS

h1000-U NI

h1000-U NI

h1000

System

Instrument

N MEA

Sentences

GPS N MEA

Sentences

GPS + Instrument
N MEA Sentences

 

 

Configuring Selectable NMEA 

Identify the Universal Interface Box you wish to configure, this is identified by the first three digits of the serial 

number found on the printed label located inside the lid of the interface box. Select the chosen box from the list 
displayed, select either 

NMEA In

 or 

NMEA Out

. The options available are detailed as follows: 

 

Selecting NMEA Input sentences

 – ‘

Current Input

’ - Press 

ENTER

 to select, press 

ENTER

 again and scroll 

through the listed sentences, press 

ENTER

 to view the options. Press 

ENTER

 and scroll to either 

On

 or 

Off

press 

ENTER

 to make your selection. Scroll to 

OK

 to return to the listed sentences. Repeat the operation until 

you have made all your selections. 

 

Selecting NMEA Output sentences

 – ‘

Current Output

’ - Follow the same procedure as detailed above. 

 

Renaming the interface box

 – ‘

Name

’ - Press 

ENTER

 to re-name the interface box (if required), use the 

UP/DOWN

 arrow keys to select the number or letter required (maximum 10 characters), once you have 

completed your name change scroll to, and highlight OK, press ENTER  to return to the Remote units screen. 

 

 

www.bandgservice.co.uk

Summary of Contents for B&G H1000

Page 1: ...universal interface box installation IS 2509 02 www bandgservice co uk ...

Page 2: ...nterference the user is encouraged to try to correct the interference by relocating the equipment or connecting the equipment to a different circuit Consult an authorised dealer or other qualified technician for additional help if these remedies do not correct the problem This device meets requirements for CFR47 Part 15 of the FCC limits for Class B equipment The h1000 meets the standards set out ...

Page 3: ...ge without notice B G reserves the right to change or improve its products and to make changes in the content without obligation to notify any person or organisation of such changes technical specifications Dimensions 70mm x 135mm x 35mm Power Supply 12V dc nominal 10V to 16V via Fastnet 2 Current Consumption 50mA typical Operating Temperature range 0 C to 55 C Storage Temperature range 25 C to 70...

Page 4: ...ard specifications for the interconnection of marine electronic instruments These standards specify the electrical signals and the format of the data that is transferred This allows equipment such as the h1000 to communicate with other manufacturers equipment The Universal Interface is an NMEA interface specifically designed to allow the h1000 system to talk with other manufacturers equipment The ...

Page 5: ...tude and Longitude GSA GNSS DOP and Active Satellites GSV GNSS Satellites in View HDG Heading Magnetic Deviation and Variation MWD Wind Direction and Speed TWD M T and TWS MWV Wind Speed and Angle AWS and AWA flag set to R RMB Recommended minimum navigation information RMC Recommended minimum specific GNSS data VHW Water Speed and Heading M T VTG Course Over Ground and Speed Over Ground ZDA Time a...

Page 6: ...ion DPT Transducer Depth and Offset GGA Global Positioning System Fix Data GLL Geographic Position Latitude and Longitude HDG Heading Magnetic Deviation and Variation HDM Heading Magnetic HDT Heading True MTW Water Temperature C MWD Wind Direction and Speed TWD M T and TWS MWV Wind Speed and Angle AWS and AWA flag set to R RMB Recommended minimum navigation information RMC Recommended minimum spec...

Page 7: ... inside the lid of the interface box Select the chosen box from the list displayed select either NMEA In or NMEA Out The options available are detailed as follows Selecting NMEA Input sentences Current Input Press ENTER to select press ENTER again and scroll through the listed sentences press ENTER to view the options Press ENTER and scroll to either On or Off press ENTER to make your selection Sc...

Page 8: ...s allow connection to the rest of the system for the supply of power and data The table below shows pin functions Pin Number Signal 1 12V 2 Busy 3 Fastnet 4 Fastnet 5 0V GROMMET CABLE TIE Push the cable s through the grommet so that the outer insulation shows beyond the grommet and secure using a cable tie as shown in the diagram opposite www bandgservice co uk ...

Page 9: ... interface box as shown in the diagram opposite method To open the connector carefully push a small flat headed terminal screwdriver into the slot directly above the relevant terminal number Push the bare end of the wire into the terminal connector and withdraw the screwdriver Note The maximum sink current for any alarm connected to this interface box is 18mA www bandgservice co uk ...

Page 10: ...62 BOX BASE OUTLINE Drill 4 off holes 2 9mmØ for No 6 x 3 4 self tapping screws WARNING THIS DRAWING IS NOT TO SCALE Use the Installation instructions and the template provided with the unit packaging to install the Interface Box www bandgservice co uk ...

Reviews: