DIP SWITCH SETTINGS
20221511 / D
91
ICIF board
1
8
ON
1
8
ON
1
8
ON
S1
S2
S3
J14
J11
J10
J9
J8
J7
S1
S2
S3
J6 J5
J15
DIP switch settings on ICIF board
SWITCH
DEFAULT
FUNCTION
DESCRIPTION
S1-1
ON
Control unit type
OFF = Expanded, ON =Compact
S1-2
OFF
Master compass type
OFF = Standard, ON =High Speed
S1-3
OFF
Control unit type
OFF = Expanded, ON =Dual
S1-4
OFF
2 gyros used
OFF = No,
ON =Yes
SW1-5 OFF
SW1-6 OFF
= No external sensor
SW1-5 OFF
S1-5 OFF
SW1-6 ON
Not used
SW1-5 ON
SW1-6 OFF
= External sensor connected
SW1-5 ON
S1-6 OFF
External sensor
connection
SW1-6 ON
Not used
S1-7
OFF
Serial signal format
OFF = IEC61162-2
(NMEA0183, ref. page 4)
,
ON = Tokimec
S1-8
OFF
Alarm output setup
OFF = All alarms,
ON = Only power failures
DEFAULT SETTINGS
Summary of Contents for 000-15567-001
Page 1: ...INSTRUCTION MANUAL SIMRAD GC80 85 COMPACT Gyro Compass 20221511D English ...
Page 16: ...Simrad GC80 GC85 Compact Gyro Compass 8 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 30: ...Simrad GC80 GC85 Compact Gyro Compass 22 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 64: ...Simrad GC80 GC85 Compact Gyro Compass 56 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 72: ...Simrad GC80 GC85 Compact Gyro Compass 64 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 84: ...Simrad GC80 GC85 Compact Gyro Compass 76 20221511 D ...
Page 90: ...Simrad GC80 GC85 Compact Gyro Compass 82 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 96: ...Simrad GC80 GC85 Compact Gyro Compass 88 20221511 D THIS PAGE INTENTIONALLY LEFT BLANK ...