EMS/First Responder 

Helmet Removal System

Instructions and Safety Information 

See reverse side of this sheet for 

EMS helmet removal instructions.

To Prepare the CO2 Infl ator:

Use only Simpson Eject 16g non-threaded 
CO2 cartridges, other cartridges may not fi t 
properly. 

Make sure the red safety lever is in the down 
position. 

1.

 Unscrew infl ator head from cartridge cup. 

2.

 Shake cartridge. 

3.

 Insert a NON-THREADED CO2 cartridge 

into the cup so the narrow end faces up. 

Thread infl ator head onto the cup, turning in 
until the cartridge just contacts the puncture 
pin, then quickly and fi rmly twist to puncture 
(activate) and seal the CO2 cartridge. 

Infl ator is now charged and ready for use.

Eject

®

 Helmet Removal System

CO2 Infl ator and Cartridge Operating Instructions:

Figure A.

Step 1.

Step 2.

Step 3.

Do not inhale CO2 gas. Do not 
discharge CO2 gas towards face, 
body, or people. CO2 gas becomes 
extremely cold when dispensed and 
should not be exposed to bare skin 
as frostbite may occur.

•  DO NOT modify the Eject

®

 Helmet 

Removal System in any way. 
Modifi cations may affect the 
proper function.

•  Never use any device not approved 

by Simpson for infl ation. This 
can result in injury to the rider/driver. 

WARNING: 

You must completely understand 

all Eject

®

 Helmet Removal System User 

Instructions and safety information before 
using this product.

Safety Lock Feature:

Do not activate a CO2 cartridge until ready 
to use.

Move the red safety lever to the “up” position to 
lock the dispensing trigger. (Figure A.) To unlock 
the dispensing trigger, move the red safety lever 
into the “down” position.

CO2 can ONLY be dispensed when the safety 
lock is in the unlocked “down” position.

All CO2 gas must be expelled from used 
cartridge before replacement of CO2 cartridge. 
Use a new cartridge each time you infl ate an 
Eject

®

 unit.

Package may contain any of the following:

Contact Eject

®

 Customer Support 

at 1-800-654-7223 or email us at 

[email protected] for 
more information, training materials 
or technical questions. 

IMPORTANT

SAFETY INFORMATION

•  These instructions are for 

Emergency Medical Services (EMS) 
to follow when responding 
to an accident.

•  Simpson recommends that the 

Eject

®

 Helmet Removal System be 

used ONLY by rescue personnel 
trained in spine immobilization 
who have complete training on 
the system and have read the 
full instructions. Proper training 
includes practicing before using the
Eject

®

 System on an accident site.

 

Figure B.

DO NOT infl ate the Eject

®

 system 

if there is structural damage to the 
top of the helmet.

Determine whether Eject

®

 is 

installed in the rider/driver’s 
helmet.

Look for “Eject

®

 Equipped” helmet sticker 

and connector protruding from base of 
helmet. (Figure B.)

This should be located on the left side of 
the helmet. Check the inside chin bar area 
for sticker if rider/driver is positioned such 
that the left side is covered.