CN-Series Hardware Installation and Maintenance Guide
About Hardware Upgrades
Specification
Maximum System Limit
Vibration (operating)
0.26Grms at 5-350Hz in all orientations.
Vibration (storage)
1.87Grms at 10-500Hz for 15 minutes (all six sides tested).
Shock (operating)
One shock pulse in the positive z axis (one pulse on each side of the system) of 31G +/–
5% for +/–10%; in the operational orientation.
Shock (storage)
Half sine shock on all six sides of 71G +/– 5% with a pulse duration of 2ms +/–10%;
square wave shock on all six sides of 27G with velocity change at 235 in/sec or greater.
Altitude and Airborne Contaminants
The following table describes the maximum altitude and airborne contaminants specifications for all
CN-Series system models.
Specification
Maximum System Limit
Altitude (operating)
-15.2m to 3048m (–50 ft to 10,000 ft)
Altitude (storage)
-15.2m to 12,000m (–50 ft to 39,370 ft)
Contaminant level (operating)
Class G1 or lower as defined by ISA-S71.04-1985
Agency Compliance
The following table lists agency compliance for all CN-Series systems.
Standard
FCC 47 CFR Part 15 Subpart B: 2012
EN 55022:2010 COR 2011
CISPR 22:2008
EN 55024:2010
CISPR 24:2010
COR 2011
VCCIV3:2009
ANSI/UL 60950-1, 2nd Edition (2007)
CSA C22.2 No. 60950-1 2nd Edition (2007)
IEC 60950-1:2005 (2nd Edition); Am 1:2009
RoHS EU Directive 2002/95/EC
About Hardware Upgrades
If you would like to upgrade the system hardware components, contact
.
Warning:
Never install additional options in the other than those approved for installation by
SimpliVity. Doing so will void your warranty and might cause serious system instability and
potential data loss.