In the case of fire retardant doors, you must ensure that the supplied
profile cylinder inlay is pressed against the snap-in mechanism in the
inside fitting.
No water or moisture must penetrate the door or reach the inner side.
Always use the WP version for moisture.
Programme SmartHandle 3062 before installing.
SmartHandle 3062 may be difficult to fit in mortise locks with a
retaining nut. You must not alter the retaining nut in any way, using a file,
for example; otherwise, the handle's guide piece will no longer fit
accurately.
When installing SmartHandle, you must ensure that the cable does not
get caught or fitted too tightly to the door.
7.2.4 Assembly Snap-In Door Monitoring
These installation instructions are designed for a standard door with a self-
locking panic lock (SLP lock) already fitted. Old fittings must be fully
removed before SmartHandle 3062 SmartHandle is installed.
IMPORTANT
To ensure full functionality, SmartHandle must always be used in combin-
ation with a self-locking panic lock (SLP lock). Please observe conformity
declarations of lock manufacturers in accordance with EN 179!
All steps must be completed in order after one another to ensure correct
installation.
SmartHandle
(Manual)
7. Installation (manual)
37 / 136