background image

User manual - POWER SUPPLY TRS-09a 

This   is   a   class   A  unit.   In   housing   or   a   similar   area   it   can   cause   radio  
frequency  interference.   In such  cases  the user  can  be requested  to  use  
appropriate preventive measures. 

Detailed informations about installation of TRS system user can find in:

“User manual for Temperature and Humidity Recording System”

.

4. 

       DEVICE INSTALLATION

 

 

The unit has been designed and manufactured in a way assuring a high level of user 

safety and resistance to interference occurring in a typical industrial environment. In order to 

take full advantage of these characteristics installation of the unit must be conducted correctly 
and according to the local regulations.

- Read the basic safety requirements on page  3 prior to starting the installation.

-  Ensure that the power supply network voltage corresponds to the nominal  

voltage stated on the unit’s identification label.

- The load must correspond to the requirements listed in the technical data.

- All installation works must be conducted with a disconnected power supply.

- Protecting the power supply clamps against unauthorized persons must be  

taken into consideration.

4.1. 

 

     UNPACKING

 

 

After removing the unit from the protective packaging, check for transportation damage. 

Any transportation damage must be immediately reported to the carrier. Also, write down the 

unit serial number on the housing and report the damage to the manufacturer.

Attached with the unit please find:
- warranty,
- user’s manual fo

TRS-09a 

unit (device)

4.2. 

 

     ASSEMBLY

 

 

- Disconnect the power supply prior to starting assembly.

- Check the correctness of the performed connections prior to switching the unit on. 

To install the device prepare pinholes accordingly to  Figure 4.1. Back side of the 

case (with mounting holes) should be mounted to a wall using screws.

5

Summary of Contents for TRS-09a

Page 1: ...6 User manual POWER SUPPLY TRS 09a Designed for TRS system Read the user s manual carefully before starting to use the unit or software Producer reserves the right to implement changes without prior n...

Page 2: ...n of symbols used in the manual This symbol denotes especially important guidelines concerning the installation and operation of the device Not complying with the guidelines denoted by this symbol may...

Page 3: ...ched off and disconnected from the power supply prior to starting installation of troubleshooting in the case of malfunction Neighbouring and mating equipment must meet the requirements of appropriate...

Page 4: ...efficiency max 200 mA Control voltage 7V 12V DC max 2mA Protection level IP 65 ABS casing Housing type Housing material Housing dimensions L x W x D without glands with glands wall mounted ABS 110 x 8...

Page 5: ...etwork voltage corresponds to the nominal voltage stated on the unit s identification label The load must correspond to the requirements listed in the technical data All installation works must be con...

Page 6: ...circuit breaker located near the unit In the case of using a monopolar fuse it must be mounted on the phase cable L The power supply network cable diameter must be selected in such a way that in the...

Page 7: ...ransmission cables together with power supply cables and cables controlling induction loads e g contactors Such cables should cross at a right angle Contactor coils and induction loads should be equip...

Page 8: ...nes connectors GND GND of supply output and control input Figure 4 4 Connection of TRS 09a module to the network 8 5 8 7 6 4 3 1 2 DATA DATA RS 485 ctrl GND 12V out shield 230V AC J1 J2 LED indicator...

Page 9: ...network at the same time When power supply of first TRS 09a module is turned off then following power supply modules will be turned off sequentially Figure 4 6 Cascade of power supply modules TRS 09a...

Page 10: ...rked with this symbol should not be placed in municipal waste Please check local regulations for disposal and electronic products 5 SELECTION OF OPERATION MODE The selection of operation mode can be d...

Page 11: ...User manual POWER SUPPLY TRS 09a Figure 5 1 Selection of operation mode 11 5 8 7 6 4 3 1 2 J1 J2 Operation mode selection jumpers J1 J2 J1 J2 J1 J2 Stand alone mode Externally controlled mode or...

Page 12: ...SIMEX Sp z o o ul Wielopole 7 80 556 Gda sk Poland tel 48 58 762 07 77 fax 48 58 762 07 70 http www simex pl e mail info simex pl...

Reviews: