User manual for - TEMPERATURE TRANSDUCER TRS-02a 

1. 

       BASIC REQUIREMENTS AND USER SAFETY

 

 

-

 The manufacturer is not responsible for any damages caused by 

inappropriate installation, not maintaining the proper technical condition 
and using the unit against its destination.

- Installation should be conducted by qualified personnel . During installation all 

available safety requirements should be considered. The fitter is responsible for 

executing the installation according to this manual, local safety and EMC 

regulations.

- The unit must be properly set-up, according to the application. Incorrect 

configuration can cause defective operation, which can lead to unit damage or 

an accident. 

If in the case of a defect of unit operation there is a risk of a serious threat 

to the safety of people or property additional, independent systems and 
solutions to prevent such a threat must be used.

-  

The unit uses dangerous voltage that can cause a lethal accident. The unit 

must be switched off and disconnected from the power supply prior to 
starting installation of troubleshooting (in the case of malfunction).

- Neighbouring and mating equipment must meet the requirements of appropriate 

standards and regulations concerning safety and be equipped with adequate 

anti-overvoltage and anti-interference filters.

-

 Do not attempt to disassemble, repair or modify the unit yourself. The unit 

has no user serviceable parts. Units, in which a defect was stated must be 
disconnected and submitted for repairs at an authorized service centre.

- Do not use the unit in areas threatened with excessive shocks, vibrations, 

corrosive gasses and oils.

- Do not use the unit in explosion hazard areas.

- Do not use the unit in areas with significant temperature variations, exposed to 

icing.

- Do not use the unit in areas exposed to direct sunlight. 

- Make sure that the ambient temperature (e.g. inside the control box) does not 

exceed the recommended values. In such cases forced cooling of the unit must 

be considered (e.g. by using a ventilator).

The unit is designed for operation in an industrial environment and must 
not be used in a household environment or similar. 

3

Summary of Contents for TRS-02a

Page 1: ...RANSDUCER TRS 02a Firmware v 2 04 or higher Input type Pt100 Designed for TRS system Read the user s manual carefully before starting to use the unit or software Producer reserves the right to impleme...

Page 2: ...ISSION ERRORS DESCRIPTION 12 6 4 EXAMPLES OF QUERY ANSWER FRAMES 12 7 FORCING OF 0XFF ADDRESS 15 Explanation of symbols used in the manual This symbol denotes especially important guidelines concernin...

Page 3: ...be switched off and disconnected from the power supply prior to starting installation of troubleshooting in the case of malfunction Neighbouring and mating equipment must meet the requirements of appr...

Page 4: ...100 type with automatic connection recognition 2 3 or 4 wires Measurement range 50 C up to 550 C Measurement error 0 2 Measurement wires resistance max 20 every wire Number of modules in 1 network max...

Page 5: ...safety requirements on page 3 prior to starting the installation All installation works must be conducted with a disconnected power supply 4 1 UNPACKING After removing the unit from the protective pac...

Page 6: ...overs and sealing packing protecting against water intrusion pay special attention to their correct tightening or clamping In the case of any doubt consider using additional preventive measures covers...

Page 7: ...terminals Figure 4 3 Location of elements inside the module case Last module in the network must be terminated with 100 150 Ohm resistor Figure 4 4 Connection of the module to the network 7 max 2 mm...

Page 8: ...connected to the device in typical 4 wire circuit Figure 4 6 a 3 wire circuit Figure 4 6 b or 2 wire circuit Figure 4 6 c Due to precision of measurement 4 wire circuit is recommended If 2 wire circu...

Page 9: ...nit is operating Excessively high temperatures cause faster ageing of the internal components and shorten the fault free time of unit operation In cases where the unit gets dirty do not clean with sol...

Page 10: ...All settings are stored in non volatile EEPROM memory and available under fixed register numbers LED indicator is installed in the module mainboard it indicates following situations normal operation...

Page 11: ...0 1 C U2 code no decimal point included e g value 155 means shifting of 15 5 C 07h 08h see descr Calibration registers do not change WARNING modification of these registers causes recalibration of mo...

Page 12: ...02h illegal register address 03h illegal data value 10h water inside module 20h temperature sensor damaged 40h exceed of lower border of input range 50 C sensor damage possible 80h exceed of upper bo...

Page 13: ...int Decimal point position can be read from reg 03h b The answer if an error occur ADDR FUNC ERROR CRC L H 01 83 40 40 C0 ERROR error code 40h bottom border of the measurement range is exceeded 2 Read...

Page 14: ...a The answer we assume that input signal is not out of range ADDR FUNC BYTE C DATA H1 L1 DATA H2 L2 CRC L H 01 03 04 00 C1 00 00 AB CF DATA H1 L1 reg 01h 193 measurement value 19 3 C DATA H2 L2 reg 0...

Page 15: ...iguration process To force address of device to value 0xFF turn module power supply and wait until it s LED indicator flashes every 10 second Next press internal switch button and hold it at least 4 s...

Page 16: ...SIMEX Sp z o o ul Wielopole 7 80 556 Gda sk Poland tel 48 58 762 07 77 fax 48 58 762 07 70 http www simex pl e mail info simex pl...

Reviews: