User manual - COUNTER SLN-94
Description:
S
- initialisation of the counting cycle,
A, B, D
- points while counter exceeds selected value,
C
- automatic initialisation of counting cycle
Figure 6.6
Example of relay outputs driving
during downcounting (parameter ”
Ar
”=”
on
”)
6.5.
CONTROL OF THE RELAY OUTPUTS (STANDARD MODE)
In standard mode, only relay R1 is controlled by counter. The principle of control is the
same as in batcher mode, so read carefully chapter 6.4. The only difference in controlling of
the relay is the interpretation of parameters
“tr1”
and
“mr1”
.
In standard mode, after initialisation of counting cycle (point S, Figure 6.7a) relay output is
driven to
inactive
. During control cycle relay outputs can change its state to
active
only
when
the counter reach
threshold value
(
“Pr1”
while upcounting, and „
000
” while downcounting).
Parameter
“tr1”
defines time during which relay R1 stays
active
after counter reach
threshold value
.
23
displayed value
State of
relay R1
„
mr1
” = on
„
tr1
” > 0
t
t
t
„
mr2
” = on
„
tr2
” > 0
S
A
B
D
C
„
Pr1
”
(initial value)
„
Pr2
”
(relay
R2
threshold)
„
000
”
(relay
R1
threshold)
unknown
state
a)
b)
c)
State of
relay R2
„tr1”
„tr2”
„dLy”