- Do not use the unit in areas where there is risk of explosions.
- Do not use the unit in areas with significant temperature variations, exposure to
condensation or ice.
- Do not use the unit in areas exposed to direct sunlight.
- Make sure that the ambient temperature (e.g. inside the control box) does not
exceed the recommended values. In such cases forced cooling of the unit must
be considered (e.g. by using a ventilator).
The unit is designed for operation in an industrial environment and must
not be used in a household environment or similar.
2.
GENERAL CHARACTERISTICS
Universal programmable counter type
is equipped with many modern features
required in simple and advanced automatic control systems. The counter had been designed
for hard environment conditions, and increased usefulness.
The unit is assembled in panel mounted case with programming keyboard on front panel,
and terminals on back panel. User can use local keyboard to set all necessary parameters due
to his own requirements. Build in RS-485 communication interface enables controlling of all
settings by host, and allows use of unit in advanced network systems.
Two counting inputs (pulse inputs) can operate in few different modes (as two
independent pulse inputs or single quadrature input). Additional programmable input can
change basic function of counting inputs (addition or subtraction of pulses from inputs,
change the direction of counting) or to stop counting without clearing.
is equipped with independent clearing input. The device can be
equipped with two or four relay (or OC type) outputs with independent thresholds, which can
be used to control external devices. The counters
are designed for cooperation with
electronic (PNP and NPN) detectors, and mechanical detectors – switches (build in digital
filter allows connectors denouncing). All inputs are separated from ground of counter, and
power supply.
3.
TECHNICAL DATA
Power supply voltage
(depending on version)
External fuse (required)
Power consumption
85...
230
...260V AC/DC; 50 ÷ 60 Hz
(separated)
or 19...
24
...50V DC and 16...
24
...35V AC (separated)
T - type, max. 2 A
max. 4,5 VA @ 85 ÷ 260V AC/DC
max. 4,5 VA @ 16V ÷ 35V AC
max. 4,5 W @ 19V ÷ 50V DC
Pulse inputs
A and B inputs
C input
D input
COM
counting (terminal no. 16,17)
programmable (terminal no. 18)
reset counter
(terminal no. 19)
common terminal (terminal no. 20)