12
6.3
Specifications and performance
Technical characteristic
Unit of
measurement
Models
PL 4520
PL 5020
PL5520
PL 6020
PL 7520
Operating pressure
Bar
300÷160
300÷160
300÷160
300÷160
300÷180
Required oil flow
l/min
65÷140
90÷160
70÷140
90÷160
110÷180
Drum speed
rpm
150÷230
130÷200
150÷230
130÷200
120÷190
Max. hydraulic motor power
kW
35
45
35
45
50
HP
48
61
48
61
68
Weight
(*)
kg
770
840
825
930
1050
(*) Standard machine set-up, with no optionals, no built-in water system, and with a universal adapter
plate.
IMPORTANT
In the event of set-ups featuring optionals, the correct weight (which is different to the
one stated in the table) will be specified on the CE data plate.
Example of how to calculate the hydraulic motor power:
Q (l / min) x P (bar)
= A (HP) / 1.36 = A (kW)
450
Key:
Q=
Capacity
P= Pressure
A=
Power
N.B.
The flow and pressure rates stated in the equation above must be measured at exactly the same time,
using a precision tool. The measurement must be carried out by a skilled member of staff.
Quoting the "model" and the "serial number" will make it easier for our Service Department to respond to your
enquiries quickly and effectively.
Make sure you have the machine’s model and serial number to hand whenever you have to contact our
Service Department. The registration details can be found on the identification plate (see
chapter 4
).