background image

New Deep Well Installation 

7

For parts or assistance, call Simer Customer Service at 1-800-468-7867

4” Or Larger Well 

(Figure 10)

1.  Install the control valve and pressure gauge in the pump body. See 

Figure 7.

2.  Assemble ejector kit FP4800 (kit sold separately). See Figure 10. Follow 

the instructions included with the kit in order to match the nozzle and 
venturi to your well conditions.

3.  Mount the pump as close to the well as possible. 
4.  Connect two pipes (1” drive, 1-1/4” suction) to the ejector and lower 

the ejector into the well until it is five feet from the bottom. It should 
also be at least 10 feet below the well’s water level while the pump is 
running in order to prevent the pump from sucking air.

5.  Install a sanitary well seal and connect the ejector piping to the pump. 

Use steel nipples through the well seal with flexible poly pipe to avoid 
crushing the plastic pipe when tightening the seal.

6.  Support the pipe so that there are no dips or sags in the pipe, so it 

doesn’t strain the pump body, and so that it slopes slightly upward 
from the well to the pump (high spots can cause air pockets which can 
air lock the pump). Seal the suction pipe joints with Teflon™ tape or 
a Teflon™ based pipe joint compound. Joints must be air- and water-
tight. If the suction pipe can suck air, the pump cannot pull water from 
the well.

You have just completed the plumbing for your new double pipe deep well 
jet pump. Please go to Page 8 for discharge pipe and tank connections.

2” Well 

(Figure 11)

1.  Install the control valve and pressure gauge in the pump body. See 

Figure 7.

2.  Mount the pump as close to the well as possible. 
3.  Assemble ejector kit FP4840 (kit sold separately), well piping, and 

well head adapter according to the instructions provided with the 
ejector package. See Figure 11. Use galvanized drop pipe with turned 
couplings to allow proper flow. Follow the instructions included with 
the kit in order to match the nozzle and venturi to your well conditions.

4.  Run two pipes (one smaller drive pipe, one larger suction pipe) from 

the well to the pump. Support the pipe so that there are no dips or sags 
in the pipe, so it doesn’t strain the pump body, and so that it slopes 
slightly upward from the well to the pump (high spots can cause air 
pockets which can air lock the pump). Seal the suction pipe joints with 
Teflon™ tape or a Teflon™ based pipe joint compound. Joints must be 
air- and water-tight. If the suction pipe can suck air, the pump cannot 
pull water from the well.

You have just completed the plumbing for your new single pipe deep well 
jet pump. Please go to Page 8 for discharge pipe and tank connections.

P

Suction (Larger)

Pipe from Well

To Household

Water System

Pressure 

Gauge and 

Priming

Plug

Well

Head

Drive (Smaller)

Line to Well

Venturi

Nozzle

Ejector

Not

to

Scale

Foot Valve

Strainer

266 0395

Relief Valve

Figure 10: 4” and Larger Deep Well

Figure 11: 2” (Single Pipe) Deep Well

41

JET  NO.

J32P-

24

P

Suction (Larger)

Pipe from Well

To Household

Water System

Pressure Gauge

and Priming

Plug

Well

Head

Drive (Smaller)

Pipe to Well

Well Casing

serves as

Drive Pipe

Suction Pipe

Venturi

Nozzle

Ejector

Not

to

Scale

267 0295

Relief Valve

Summary of Contents for 3305P

Page 1: ...g installation or maintenance assistance Call 1 800 468 7867 English Pages 2 16 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Co...

Page 2: ...tor terminals If in doubt consult a qualified electrician General Safety Do not touch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump a...

Page 3: ...pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local disposal ordinances Exceptions to the Twelve 12 Month...

Page 4: ...motor 1 Drain and remove the old pump Check the old pipe for scale lime rust etc and replace it if necessary 2 Install the control valve and pressure gauge in the pump body see Figure 1 3 Install eje...

Page 5: ...ee well points to one suction pipe You have just completed the suction piping for your new shallow well jet pump Please go to Page 8 for discharge pipe and tank connections 1 E I DuPont de Demours and...

Page 6: ...foot valve and suction pipe see Figure 9 Make sure that the foot valve works freely Use Teflon tape or a Teflon based pipe joint compound on threaded pipe joints Protect the foot valve assembly from...

Page 7: ...2 Well Figure 11 1 Install the control valve and pressure gauge in the pump body See Figure 7 2 Mount the pump as close to the well as possible 3 Assemble ejector kit FP4840 kit sold separately well p...

Page 8: ...he open arm of the first tee Put a priming plug in one arm of the second tee 3 Run a pipe from the open arm of the second tee to the inlet port of your tank The pipe size must be at least as large as...

Page 9: ...s Use the wire size including the ground wire specified in the wiring chart If possible connect the pump to a separate branch circuit with no other appliances on it Explosion hazard Do not ground to a...

Page 10: ...the pressure switch and the motor for motor grounding protection If the pressure switch is not connected to the motor connect the green ground screw in the switch to the green ground screw under the...

Page 11: ...control valve each time before you start the pump 5 When water pressure has built up and is maintained by the pump slowly open the control valve see Figure 18 this will let water flow to the residenti...

Page 12: ...wer on Start the pump The pump should pump water in two or three minutes 4 If you don t have water after 2 or 3 minutes stop the pump and remove the fill plugs Refill the pump and piping You may have...

Page 13: ...r pump house Foot valve and or strainer are buried in sand or mud Raise foot valve and or strainer above bottom of water source Clean foot valve and strainer Water level is too low for shallow well se...

Page 14: ...Pump Body Front Half L76 37P 7 Control Valve Assembly L162 10PS 8 Overhaul Kit FPP1511 FPP1512 FPP1513 9 Pressure Switch Assembly TC2151 Ref Part Description Model and HP 3325E 1 2HP 3327E 3 4HP 1 Mot...

Page 15: ...Venturi Shallow Well 3327E N32P 67B 4 Gasket N20 25 5 Pipe Plug U78 56ZPS 6 Socket Head Capscrew 2 Req U30 961PS 7 Check Valve N212 12P Shallow Well Kit FP4855 for 3325E 3327E NOTICE Use care not to d...

Page 16: ...well is more than the distance listed in the Depth column for your pump you MUST use the nozzle venturi combination listed or your pump will not be able to lift water from the well Nozzle Venturi Com...

Page 17: ...us pour fonctionner par des temp ratures lev es Pour ne pas se br ler lorsque l on interviendra sur la pompe la laisser refroidir pendant 20 minutes apr s l avoir arr t e avant de la toucher Ne pas l...

Page 18: ...fins de garantie retourner l tiquette figurant sur le cordon de la pompe et l original du re u au d taillant Mettre la pompe au rebut conform ment la r glementation locale Exceptions la garantie limi...

Page 19: ...e et le manom tre dans le corps de la pompe voir la Figure 1 3 Poser le n cessaire d jecteur FP4875 ou le n cessaire FP4855 les n cessaires sont vendus s par ment Suivre les instructions fournies avec...

Page 20: ...e jecteur neuve pour puits profonds sur la tuyauterie du puits est maintenant termin Passer la page 23 pour le branchement du tuyau de refoulement et sur un r servoir 1 E I DuPont de Demours and Compa...

Page 21: ...a Figure 9 S assurer que le clapet de pied fonctionne librement Utiliser du ruban T flon ou de la p te pour raccords filet s base de T flon sur les raccords filet s Poser une cr pine autour du clapet...

Page 22: ...terie du puits et l adaptateur de la t te du puits conform ment aux instructions fournies avec l jecteur Voir la Figure 11 Utiliser un tuyau de descente galvanis muni de raccords usin s pour assurer u...

Page 23: ...me t et l orifice d admission du r servoir Le diam tre du tuyau doit tre au moins aussi grand que le diam tre de l orifice de refoulement de la pompe 4 D poser le bouchon filet de 1 8 de pouce NPT de...

Page 24: ...er la pompe sur un circuit s par sur lequel aucun autre appareil ne sera branch Risque d explosion Ne pas mettre la terre sur une conduite de gaz Figure 15 Tension r gl e 115 V sur s lecteur cadran Fi...

Page 25: ...n 2 Il doit y avoir un raccordement en m tal solide entre le manostat et le moteur pour une protection la terre du moteur Si le manostat n est pas branch sur le moteur brancher la vis verte de mise la...

Page 26: ...tenue par la pompe ouvrir lentement la vanne de r gulation voir la Figure 18 pour que l eau circule dans les conduites de l habitation Observer la pression indiqu e par l aiguille du manom tre Continu...

Page 27: ...per l eau dans les deux ou trois minutes qui suivent 4 Si la pompe ne pompe pas d eau dans les 2 ou 3 minutes qui suivent l arr ter et d poser les bouchons de remplissage Faire le plein de la pompe et...

Page 28: ...pet de pied et ou la tr mie sont enfouis dans le sable ou la boue Relever le clapet de pied et ou la cr pine plus haut que le fond de la source d eau Nettoyer le clapet de pied et la cr pine Dans le c...

Page 29: ...ses avec tous les n cessaires de r paration R f D signation Mod le et puissance en ch 3305P 1 2 ch 3307P 3 4 ch 3310P 1 ch 1 Moteur J218 582A 115 PKG J218 590 PKG J218 596 PKG 2 Manom tre TC2104 3 Cor...

Page 30: ...s le sch ma ci dessus sinon il risquera d y avoir des fuites internes 1 2 3 4 5 12 6 7 8 9 10 11 1722 0495 Trousse pour puits peu profond FP4875 Pour 3305P 3307P et 3310P Ref D signation Num ro des pi...

Page 31: ...s 1 1 4 NPT 5 U11 1 Pi ces non illustr es Gicleur Venturi Combinaison Trousse FP4800 Modele Profondeurs inf rieures Gicleur Venturi Profondeurs inf rieures Gicleur Venturi 3305P 50 15 2 m J34P 41 51...

Page 32: ...para operar a temperaturas altas Para evitar quemaduras al realizar el servicio a una bomba d jela enfriar por 20 minutos despu s de apagarla No permita que la bomba o cualquier componente del sistem...

Page 33: ...omba cloacal ha fallado Use guantes de caucho cuando manipule la bomba Para los fines de la garant a devuelva la etiqueta del cord n de la bomba y el recibo de compra original a la tienda minorista De...

Page 34: ...1 3 Instale el kit de eyector FP4875 o el kit FP4855 los kits se venden por separado Siga las instrucciones que vienen incluidas en el kit Aseg rese de alinear el venturi con el orificio superior en...

Page 35: ...scarga 1 E I DuPont de Demours and Company Corporation Delaware In stalacion de pozo recubierto con un recubrimiento de 2 o mas Figura 6 1 Instale la v lvula de control y el medidor de presi n en el c...

Page 36: ...tuber a Proteja la conexi n de la v lvula de retenci n de peces basura etc con la instalaci n de una malla de alambre a su alrededor vea la Figura 9 5 Baje la tuber a hacia el agua hasta que el filtro...

Page 37: ...e cabeza del pozo de acuerdo con las instrucciones que vienen incluidas en el paquete del eyector Vea la Figura 11 Utilice tubo galvanizado de ca da con juntas invertidas para lograr un flujo adecuado...

Page 38: ...entrada de su tanque La tuber a debe ser al menos del mismo tama o que el orificio de descarga de la bomba 4 Retire el tap n de la tuber a de 1 8 de NPT del orificio del Control de Volumen de Aire CVA...

Page 39: ...es posible conecte la bomba a un circuito separado de derivaci n sin ning n otro artefacto en el mismo Peligro de explosi n No haga la conexi n a tierra en una l nea de suministro de gas Figura 15 Te...

Page 40: ...esi n y el motor para brindar protecci n a tierra para el motor Si el conmutador a presi n no est conectado al motor conecte el tornillo de puesta a tierra verde en el conmutador al tornillo de puesta...

Page 41: ...la v lvula de control consulte la Figura 18 esto permitir que el agua corra a las tuber as de la residencia Abra lentamente la v lvula de control mientras observa la aguja del man metro Contin e abri...

Page 42: ...que la bomba La bomba debe bombear agua despu s de 2 3 minutos 4 Si no tiene agua despu s de 2 3 minutos pare la bomba y retire todos los tapones de llenado Vuelva a llenar la bomba y la tuber a Posib...

Page 43: ...iente el recinto de bombas o el foso La v lvula de pie y o el colector est n enterrados en arena o en lodo Eleve la v lvula de pie y o el colector por encima del fondo de la fuente de agua Limpie la v...

Page 44: ...de reparaci n Ref Descripci n Modelo y HP 3305P 1 2HP 3307P 3 4HP 3310P 1 HP 1 Motor J218 582A 115 PKG J218 590 PKG J218 596 PKG 2 Medidor de Presi n TC2104 3 Cuerpo de la Bomba Mitad trasera L176 47...

Page 45: ...22 0495 Juego para pozo poco profundo FP4875 Para bombas de la 3305P 3307P y 3310P N32P 67 4 1 1 2 3 Surface B 6 7 5 4 1927 1204 Superficie B Ref Descripci n N mero de repuesto 1 Unidad del eyector N4...

Page 46: ...idad menor que Tobera Venturi Profundidad menor que Tobera Venturi 3305P 50 15 2 m J34P 41 51 J32P 24 70 21 3 m J34P 42 52 J32P 18 3307P 70 21 3 m J34P 43 53 J32P 24 100 30 5 m N A 3310P 90 27 4 m N A...

Page 47: ......

Page 48: ......

Reviews: