background image

Installation • Maintenance 

4

For parts or assistance, call Simer Customer Service at 1-800-468-7867

Plug in the Pump
AFTER the pump is completely installed, plug the switch 
into a GFCI-protected, properly grounded outlet. Plug the 
pump into the back of the switch’s plug.
Adjusting The Flow
The drain pump can pump up to 27 gallons per minute 
(GPM). Normal sink drains allow only 5 to 6 GPM to 
flow. Adjust the discharge shut-off/flow balancing valve 
as follows so that the pump does not cycle on and off 
when the faucets are on full.
1.  Run water into the sink. The pump will start when it 

detects water.

2.  Check for leaks. If leaks are found, unplug the pump 

power cord and fix the leaks before proceeding.

3.  Put a stopper in the drain and allow the sink to fill 

up a few inches.

4.  Open the discharge shut-off valve, open the faucets, 

and remove the stopper to drain the sink.

5.  The pump will start. Adjust the discharge shut-

off/flow balancing valve until the pump runs 
continuously while the faucets are running and 
the sink is draining. If the water level rises with 
the pump on, slightly open the discharge valve 
to balance the flow. If it drops, slightly close the 
discharge valve. 

Washing Machine Use
Washing machines usually discharge more water than 
the faucets do, and it is normal for the water level to rise 
in the sink while the pump is discharging. Do not adjust 
the discharge valve to match the flow w hen the washing 

machine discharges into it, unless the sink is ONLY used 
for washing machine discharge.
NOTICE: Washing machine discharge water contains fiber 
and lint. Unfiltered washing machine discharge could plug 
the pump and require pump disassembly for cleaning. 
To avoid this, install a lint trap or bag type filter in the 
washing machine discharge line and clean it regularly.

Maintenance

This pump requires very little maintenance and should 
provide a long service life. Problems are rare; when the 
pump flow drops off, the most likely cause is something 
solid going down the drain and jamming the impeller.
To clear a jammed impeller:
1.  Disconnect the pump from power.
2.  Close the discharge shutoff valve.
3.  Bail out the sink as much as possible. 
4.  Disconnect the union, unscrew the pump from the 

sink tail piece, lower the pump to the floor, and slide 
it out from under the sink (see Figure 3). 

5.  Remove the six housing screws (see Figure 4).
6.   Clean out the pump. Make sure that the pump 

discharge is clear. If necessary, replace the impeller.

7.  Install the new gasket (included with impeller). 

Reassemble the pump.

8.  Raise the pump back into position, thread it back 

onto the sink tail piece, and reconnect the union.

9.  Plug in the pump. Run water in the sink until the 

pump has run at least one complete cycle to make 
sure the pump is operating correctly and there are 
no leaks

 

Figure 4: Remove 6 housing screws to clean out pump

Figure 3: Pump removal

1-1/4” Union 
Half

1-1/4” Union Half

 

Screen

Check Valve

Laundry

Sink

Discharge Pipe

Pump

† For easier removal for servicing or cleaning,
 

install a 1-1/2” solvent union in the drop pipe.

Shut-Off/Flow-
Balancing Valve

1-1/2” PVC†

Summary of Contents for 2935B

Page 1: ...e Call 1 800 468 7867 English Pages 2 6 Installation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 468 7867 Français Pages 7 11 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 800 468 7867 Español Paginas 12 16 293 Wright St Delavan WI 53115 Ph...

Page 2: ...where a gravity drain line is not available Attach the pump to the drain tail piece the pump will start when water begins to drain Uses include basement laundry sinks wet bars and utility sinks Specifications Power supply required 115V 60 HZ Liquid Temp Range 32 120 F 0 50 C Individual Branch Circuit Required min 15 Amps Pump Inlet 1 1 2 NPT Pump Discharge 1 1 4 NPT Installation See Figures 1 and ...

Page 3: ...harge piping Step 12 8 Slide the pump up into position and glue the pipe into the male adapter on the pump Don t allow any glue to get on the pump or in the motor Make sure the pump is facing the correct direction match the marks from Step 7 Put the support in place under the motor 9 Wrap the 1 1 4 galvanized nipple with 1 1 2 to 2 turns of PTFE tape on each end and thread it into the pump dischar...

Page 4: ...harges into it unless the sink is ONLY used for washing machine discharge NOTICE Washing machine discharge water contains fiber and lint Unfiltered washing machine discharge could plug the pump and require pump disassembly for cleaning To avoid this install a lint trap or bag type filter in the washing machine discharge line and clean it regularly Maintenance This pump requires very little mainten...

Page 5: ...ve slightly System discharge line too high or too long Unplug pump and reduce height or length of discharge line 11 max height Check valve installed backwards Make sure flow arrow on check valve points away from pump Pump cycles on and off when no water is in the sink Check valve not installed Unplug pump and install check valve see Figures 2 and 3 Check valve jammed Unplug pump open discharge lin...

Page 6: ...ications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact SIMER Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose...

Page 7: ...olts 60 Hz Températures du liquide De 32 à 120 ºF de 0 à 50 ºC Circuit séparé requis 15 ampères minimum Aspiration de la pompe 1 1 2 pouce fileté Refoulement de la pompe 1 1 4 pouce fileté Installation voir les figures 1 et 2 Risque d incendie ou d explosion Ne pas utiliser dans une atmosphère explosive Ne pomper que de l eau douce avec cette pompe Son utilisation avec de l eau salée ou de saumure...

Page 8: ... la colle se fixe Laissez le en place pendant que vous mesurez et coupez la tuyauterie de refoulement Étape 12 8 Glissez la pompe en position et collez le tuyau dans l adaptateur mâle sur la pompe Veillez à ne pas déposer de la colle sur la pompe ni laisser la colle pénétrer le moteur Assurez vous d orienter la pompe dans la bonne direction appariez les marques de l étape 7 Placez le support sous ...

Page 9: ... refoule l eau à moins que l évier ne soit utilisé QUE pour refouler l eau de la laveuse AVIS L eau refoulée par une laveuse contient des fibres et des peluches La pompe risque de se boucher si elle pompe de l eau non filtrée d une laveuse Dans ce cas la démonter et la nettoyer Pour que la pompe ne se bouche pas poser une crépine à peluche ou un filtre de type à sac dans la conduite de refoulement...

Page 10: ...du système est trop haute ou trop longue Débrancher la pompe et raccourcir la hauteur ou la longueur de la conduite de refoulement hauteur maximale de 11 pieds Le clapet antiretour est installé à l envers S assurer que la flèche du clapet antiretour indiquant le sens du débit est orientée à l opposé de la pompe La pompe démarre et s arrête alors qu il n y a pas d eau dans l évier Un clapet antiret...

Page 11: ...ux d égout qui a été installée au détaillant Communiquer avec le service à la clientèle de SIMER Les pompes d eaux d égout qui ont été utilisées puis retirées présentent un risque de contamination En cas de défaillance de la pompe d eaux d égout Porter des gants en caoutchouc pour manipuler la pompe À des fins de garantie retourner l étiquette figurant sur le cordon de la pompe et l original du re...

Page 12: ... a drenar Los usos incluyen tinas de lavandería en sótanos frigobares y fregaderos de uso general Especificaciones Suministro de potencia requerido 115V 60 HZ Gama de temperatura del líquido 32 120 F 0 50 C Requiere un ramal individual min 15 Amperios Admisión de la bomba 1 1 2 NPT Descarga de la bomba 1 1 4 NPT Instalación ver figuras 1 y 2 Tensión peligrosa Puede provocar choque quemaduras o mue...

Page 13: ...ya endurecido Déjelo en esa posición mientras mide y corta la tubería de descarga Paso 12 8 Deslice la bomba hacia arriba en la posición correcta y adhiera la tubería al adaptador macho en la bomba No permita ningún depósito de pegamento sobre la bomba o que el pegamento penetre en el motor Asegúrese de que la bomba esté colocada apuntando hacia la dirección correcta haga corresponder las marcas h...

Page 14: ...adero se use SOLAMENTE para la descarga del lavarropas AVISO El agua de descarga del lavarropas contiene fibras y pelusa Una descarga no filtrada desde un lavarropas puede obturar la bomba la cual se deberá desarmar para su limpieza Para evitarlo instale una trampa de pelusa o un filtro tipo bolsa en la tubería de descarga del lavarropas y límpielos con regularidad Mantenimiento Esta bomba requier...

Page 15: ...demasiado larga Desenchufe la bomba y reduzca la altura o el largo de la tubería de descarga altura máxima 11 pies Válvula de retención instalada en posición invertida Verifique que la flecha de flujo en la válvula de retención apunte en la dirección alejada de la bomba La bomba se enciende y se apaga continuamente cuando no hay agua en el fregadero Válvula de retención no instalada Desenchufe la ...

Page 16: ...es o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comuníquese con el Departamento de Atención al Cliente de SIMER Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminación Si su bomba cloacal ha fallado Use guantes de caucho cuando manipule la bomba Para los fines de la garantía dev...