18
6.5
C.H. MODE - FAULT FINDING
Start from cold
Rotary switch set to WINTER position.
Room thermostat (if fitted) calling for heat and all D.H.W. taps off.
C.H. thermostat set to maximum position.
Clock in the on position (if fitted).
NOTE:
After completing fault finding reset the room thermostat (if fitted) to the required setting. If the appliance will not function
check the wiring to the clock and if necessary, replace the clock.
Is there power
at the external
socket?
Make
power
available
Does
the pump
start?
Does
the fan
start?
Is there a spark
at the ignition
electrode?
Turn the clock
in the right
position
Is fuse
at mains
plug OK?
Is there power
at L and N
terminals?
Is the clock in
the correct
band time?
Is smoke
pressure switch
connected right?
Check smoke pres-
sure switch and
fan
connection
Set properly
ignition probe
Is there continuity
between
ignition probe
and ground?
Replace
the clock
Replace fuse in
mains plug
Check wire
connections
to L and N
terminals
Check the
time clock does
his contacts
open and close
when the clock
turns?
Is smoke
pressure switch
closed?
Replace the smoke
pressure switch
Is the smoke
pressure switch
contact in open
position?
Make it free to
rotate
Close room
thermostat
contact
Replace
fuse F1
Is limit
thermostat
calling for heat?
Replace the
limit thermostat
Is pump shaft
free to rotate?
Is fuse
F1 OK?
Is there voltage
available
to the pump?
Is sensor
disconnected?
Connect
the sensor
Replace
sensor
Replace
the fan
Replace
the pump
Check pump
connection
Set right
the contacts
Is there
continuity
between power
terminals of
PCB control
board and
PCB ignition?
Is sensor OK?
Check gap
between the
ignition electrode
and hood, check if
the electrode
lead and fit
are not damaged.
Does it now
spark?
Is there
230V AC
available between
11 and 4
terminals
and between
11 and 10
terminals of PCB
ignition?
Replace the PCB
control board
Is there 230V AC
available at the
fan terminals?
Has the PCB
ignition
locked-out after
10 seconds
without flame
at the burner?
Has the PCB
ignition
locked-out after 10
seconds
with flame
at the burner
before lock?
Check the gap
between the
ionisation probe
and hood;
check if the
electrode lead
and fit are not
damaged.
Does it now
detect the flame?
Can the burner
pressure be
reduced by the
C.H. ajuster?
Does the burner
pressure reduce
as the temperature
rises towards max.?
Check:
1) Limit
thermostat
2) C.H.
thermistor
3) PCB control
board
Is the burner
pressure set to
the maximum?
Replace the
C.H. thermistor
Does the
boiler switch
OFF before
achieving the
temperature?
Is there a
voltage at the
modulator?
Is the gas
available?
Open
the gas
Turn the plug
Replace the
modulator
Is the safety
thermostat OK?
Replace the
safety
thermostat
Boiler is
satisfactory
Is there
continuity
between the
PCB control
board and
the gas valve?
Replace the
gas valve
Set properly
the connection
Yes
No
Is the room
thermostat
contact closed?
Yes
No
Yes
No
No
No
No
Yes
Yes
No
Yes
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
Yes
Yes
No
Yes
No
Yes
Yes
Yes
No
No
Yes
No
No
Yes
No
No
Yes
Yes
No
Yes
Yes
Yes
Yes
No
No
Yes
Yes
No
No
No
No
Yes
No
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes