22
5.11 Wiring diagram
BLACK
BLACK
BLACK
BLEU
BLEU
BLEU
BROWN
TRA
EV
F
CN11
TA2
BLEU
BROWN
PI
VD
2
3
BLEU
BROWN
BLEU
BRO
WN
230 V - 50 Hz
L
N
CD .6324930
CN6
CN5
CN3
CN17
CN4
CN1
CN15
CN14
CN13
CN12
CN2
RED
RED
RED
GREEN
WHITE
RED
RED
RED
RED
SS
PA
V
FLM
SF
TS
TFU
SM
VC
C
GND
IN
BLA
CK
BLA
CK
BLEU
RED
GREEN
BLA
CK
BLEU
BLEU
4 3 2 1
BLEU
BLEU
BRO
WN
BLA
CK
GREEN
RED
EAR
BLA
CK
BLA
CK
6
5
1
2
3
4
4
3
TA
SE
CR
OP
L
Live
N
Neutral
F
Fuse (3.15AT)
TRA
Ignition transformer
PI
Pump
V
Fan
EAR
Ignition / Detection electrode
EV
Gas solenoid valve
SS
Domestic hot water sensor (SS)
SM
Delivery sensor (SM)
TS
Safety thermostat
SF
Exhaust sensor (SF)
FLM
Flow meter
VD
Diverter valve
PA
Water pressure switch
TA-TA2
Room Thermostat
SE
External sensor
CR
Remote control (instead of room thermostat)
OP
Mechanical timer
Note: Volt free external controls (TA) are connected to terminals 5 and 6 after removal of the link.
Fig. 13
m
CAUTION
Installer must:
– Connect the boiler to a 230v -50Hz single phase
power supply through a fused mains switch, with
at least 3mm spacing between contacts, fused at
3amps
which ensures complete cut-off in overvoltage
category III conditions (i.e. where there is at least 3
mm between the open contacts)
.
– Respect the connections L (Live) - N (Neutral).
– Ensure that the special power cable is only replaced
with a cable ordered as a spare part and connected
by professionally qualified personnel.
m
CAUTION
Installer must:
– Connect the earth wire to an effective earthing sys-
tem.
Sime Ltd
declines all responsible for any inju-
ry or damage to persons, animals,or property as a
result of failure to provide adequate earthing of the
appliance.
d
DO NOT
Do not use water pipes for earthing the appliance.