6.11.1 Coaxial duct (Ø 60/100mm and Ø 80/125mm)
Coaxial accessories
Description
Code
Ø 60/100
mm
Ø 80/125
mm
Coaxial duct kit
8084813
8084830
Extension W. 1000 mm
8096103
8096130
Extension W. 500 mm
8096102
-
Vertical extension W. 200 mm with
smoke analysis take-off point
8086908
-
Adapter for Ø 80/125 mm
-
8093120
Additional 90° curve
8095801
8095820
Additional 45° curve
8095900
8095920
Tile with joint
8091300
8091300
Roof outlet terminal W. 1284 mm
8091200
8091200
Vertical condensation recovery W. 200
mm
8092803
8092803
Load loss - Equivalent lengths
Model
Leq (linear metres)
Ø 60/100
mm
Ø 80/125
mm
90° curve
1
1
45° curve
0,5
0,8
Minimum-Maximum Lengths
Model
Duct Length Ø 60/100
Duct Length Ø 80/125
W
Horizontal
(m)
H Vertical
(m)
W
Horizontal
(m)
H Vertical
(m)
Min. Max. Min. Max. Min. Max. Min. Max.
GO 18 BF
-
3,0
1,3
(*)
4,0
3,5
5,5
4,0
6,0
GO 25 BF
-
3,0
1,3
(*)
4,0
3,5
5,5
4,0
6,0
GO 30.BF
-
2,5
1,3
(*)
3,5
3,0
5,0
4,0
5,5
m
CAUTION
(*) Vertical condensate recovery MUST be introduced
for vertical ducts (Type C32) or vertical sections of the
duct (Type C42) longer than 1.3m.
Diaphragms for coaxial ducts
Boilers leave the factory provided with a diaphragm (1) with the
following characteristics:
–
GO 18 BF
: diaphragm Ø 79 mm
–
GO 25 BF
: diaphragm Ø 81 mm
–
GO 30.BF
: diaphragm Ø 86 mm.
1
Fig. 29
When the outlets are
Type C12
or
C42
the diaphragm is to be
removed or kept following the indications below:
Model
Diaphragm
for duct L
GO 18 BF
YES
(fit it)
< 1 m
GO 25 BF
GO 30.BF
GO 18 BF
NO
(do not use)
> 1 m
GO 25 BF
GO 30.BF
When the outlet is
Type C32
(vertically straight without any
curves), the presence of the diaphragm modifies the maximum
length of the duct as shown below:
Model
Diaphragm
Max L (m)
GO 18 BF
YES
1,5
GO 25 BF
GO 30.BF
GO 18 BF
NO
4,0
GO 25 BF
GO 30.BF
3,5
6.11.2 Separate ducts (Ø 80mm)
Constructing outlets for separate ducts requires the use of kit
code 8089916 (
GO 18 BF
) and kit code 8089915 (
GO 25 BF
-
GO
30.BF
). This is to be ordered separately from the boiler and when
connected to the other accessories, to be chosen from those
listed in the table, completes the flue gas outlet/ combustion air
inlet assembly.
The total maximum length obtained by adding the lengths of
the outlet and inlet pipes is determined by the load loss of the
individual accessories used and must not be greater than 7 mm
H
2
O for
GO 18 BF
, 9 mm H
2
O for
GO 25 BF
and
GO 30.BF
.
Separate accessories
Description
Code
Diameter Ø 80 (mm)
Separate ducts kit (flue gas outlet
flange, suction cup and segmented
diaphragm)
GO 18 BF
8089916
Separate ducts kit (flue gas outlet
flange, suction cup and segmented
diaphragm)
GO 25 BF
-
GO 30.BF
8089915
90° curve M-F (6 pieces)
8077410
90° curve M-F (with take-off point)
8077407
90° curve M-F (insulated)
8077408
Extension W. 1000 mm (6 pieces)
8077309
Extension W. 1000 mm (insulated)
8077306
Extension W. 500 mm (6 pieces)
8077308
Extension W. 135 mm (with take-off
point)
8077304
Wall outlet terminal
8089501
Internal and external ring nut kit
8091500
Inlet terminal
8089500
45° curve M-F (6 pieces)
8077411
Condensate recovery W. 135 mm
8092800
Manifold
8091400
Tile with joint
8091300
Roof outlet terminal W. 1390 mm
8091201
Condensate recovery Tee
8093300
Inlet/outlet fitting Ø 80/125 mm
8091401
Summary of Contents for GO 18 BF G20
Page 10: ...10 ES...
Page 18: ...18 ES...
Page 41: ...41 ES...
Page 50: ...50 EN...
Page 58: ...58 EN...
Page 81: ...81 EN...
Page 83: ...83 RU m Sime 1 1 2 OFF Sime X m Fonderie SIME S p A...
Page 84: ...84 RU d 8 8 OFF d EN 15502 60 C 5 C...
Page 90: ...90 RU...
Page 91: ...91 RU 5 92 5 1 92 5 2 92 5 3 92 5 4 93 5 5 94 5 6 95 5 7 95 5 8 95 5 9 96 5 10 96 5 11 97...
Page 98: ...98 RU...
Page 101: ...101 RU 50 mm 300 mm 900 mm 25 6 5 GO BF m 6 6 m Y R 6 7 pH 6 8 25 f 6 8 GO BF 1 2 3 1 2 3 26...
Page 109: ...109 RU 6 13 2 3 4 7 7 3 4 3 7 45...
Page 111: ...111 RU 7 3 m 1 2 1 2 49 t 6 OFF RESET 50 5 tS0 1 1 1 1 1 1 1 5 5...
Page 116: ...116 RU 7 8 Auto MAnu 1 5 m 6 7 65 tS 1 7 5 t D 5 Auto OFF RESET 66 P01 0 150 6 D 67...
Page 118: ...118 RU 8 8 1 m a OFF OFF 70 8 2 8 2 1 d 8 3 8 3 1 1 2 1 2 71 3 4 4 5 6 3 72 5 6 5...
Page 119: ...119 RU 8 3 2 8 3 3 3 5mm 0 5 0 5 73 m 8 3 4 4 4 4 74 8 4 8 4 1 8 4 2 1 8 5...
Page 121: ...121 RU...
Page 122: ...122...
Page 123: ...123...