ø 80/125
min. 7
1
5
KEY
1
Stainless steel coaxial flue L. 886 code 8096220
2a
Stainless steel extension L. 1000 code 8096121
2b
Stainless steel extension L. 500 code 8096120
3a
90° stainless steel curve MF code 8095820
3b
45° stainless steel curve MF code 8095920
4
Stainless steel vertical condensation
recovery L. 135 code 8092820
5
Tile with hinge code 8091300
6
Roof outlet terminal L. 1063 code 8091203
7
Kit code 8098812)
Fig. 4/a
TABLE A
Load loss (mt)
90° stainless steel curve MF
1,80
45° stainless steel curve MF
0,90
Stainless steel extension L. 1000
1,00
Stainless steel extension L. 500
0,50
Roof outlet terminal L. 1063
1,00
Stainless steel coaxial flue L. 886
0,70
Stainless steel vertical condensation recovery L. 135
0,70
WARNING:
The maximum acceptable
length of the flue must not be
over 7.0 equivalent meters.
Always use the condensation
recovery (4) in outlets with ver-
tical exhaust.