Type
No.
Fault
Solution
ALL
90
Combustion set
cannot be reached
error
- Check electrode
- Check outlets
- Check air diaphragm (for
BF models)
- Check gas calibration
ALL
92
System has reached
maximum air
correction error (at the
minimum flow rate)
- Check electrode
- Check outlets
- Check air diaphragm (for
BF models)
- Check gas calibration
ALL
93
Combustion set
cannot be reached
error
- Check electrode
- Check outlets
- Check air diaphragm (for
BF models)
- Check gas calibration
ALL
95
Flame signal micro
interruptions error
- Check electrode
- Check board
- Check electric power
supply
- Check gas calibration
ALL
96
Block due to clogging
in smoke outlet
- Check for blockage in
chimney
- Check the smoke outlet
and electrode position (not
touching the burner)
ALL
98
SW error, board
start-up
- Contact the Technical
Assistance Centre
ALL
99
General board error
- Contact the Technical
Assistance Centre
Type
No.
Fault
Solution
-
-
Frequent relief valve
intervention
- Check circuit pressure
- Check expansion vessel
-
-
Limited production of
domestic hot water
- Check the diverter valve
- Check that plate heat
exchanger is clean
- Check domestic hot water
circuit valve
4.6.1
Maintenance request
When it is time to perform maintenance on the boiler, the
c
symbol shows on the display.
Contact the technical assistance service to organise the
necessary work.