5.11 Wiring diagram
BROWN
BLUE
BL
UE
BL
UE
RED
RED
RED
RED
RED
GREEN
WHITE
RED
RED
BLUE
BROWN
BLA
CK
BL
UE
BLACK
230 V - 50 Hz
L
N
BLACK
BRO
WN
VD
SS
SM1
SM2
TRA
EAR
EV
F
PI
V
PA
FLM
CN6
CN5
CN3
CN17
CN4
CN1
CN15
CN14
CN13
CN12
CN11
2
3
VC
C
GND
IN
CN2
BLA
CK
BLA
CK
BL
UE
BL
UE
3
4
5
6
SE
TA
CR
L
Line
N
Neutral
F
Fuse (3.15AT - 250V)
TRA
Ignition transformer
PI
System pump
V
Fan
EAR
Ignition / Detection electrode
EV
Gas solenoid valve
SS
Domestic hot water sensor
SM1-2
Dual sensor (thermal safety/delivery)
FLM
Flow meter
VD
Diverter valve
PA
Water pressure switch
TA
Air thermostat
SE
External sensor
CR
Remote control (instead of air thermo-
stat)
To connect the "Air Thermostat" or, alternatively the "Remote Control", remove the bridge
between terminals 5-6.
Fig. 15
m
CAUTION
Users must:
– Use an omnipolar cut-off switch, disconnect switch
in compliance with EN Standards
which ensures
complete cut-off in overvoltage category III conditions
(i.e. where there is at least 3 mm between the open
contacts)
.
– Respect the connections L (Live) - N (Neutral).
– Ensure that the special power cable is only replaced
with a cable ordered as a spare part and connected
by professionally qualified personnel.
m
CAUTION
Users must:
– Connect the earth wire to an effective earthing sys-
tem.
The manufacturer is not responsible for any dam-
age caused by failure to earth the appliance or failure
to observe the information provided in the wiring dia-
grams
.
d
IT IS FORBIDDEN
To use water pipes for earthing the appliance.